HomeMy WebLinkAbout2004 02 09 Consent 207
COMMISSION AGENDA.
ITEM 207
Consent X
Informational
Public Hearing
Regular
February 9, 2004
Regular Mee:ting
~-
cSY
Mgr. / Dept.
Authorization
REQUEST:
The Parks and Recreation Department is requesting authorization to
piggyback off the City of Clewiston Bid # 02-03-11 for Irrigation Pump
Station replacement at Central Winds Park.
PURPOSE:
The purpose of this item is to request authorization to piggyback off of
The City of Clewiston Bid # 02-03-1l Irrigation pump station replacement
at Ctmtral Winds Park in the amount of$ 35, 886.02.
CONSIDERATIONS:
. FRDAP Grant 5 was approved at the 9/22/03 City Commission Mee:ting (Central Winds
Park support facilities need to be competed to meet Grant requirements).
. Parks and Recreation consulted with several Pump Station Companit~s to price out a new
Pump Station at Central Winds Park.
. The best available price is by piggybacking the City of Clewiston Bid with Hoover
Pumping Systems.
. The new pump station will be able to handle irrigation on the existing sports fields and
the new expansion practice fields.
. The Public Works/Utility Director has reviewed the Irrigation Pump Station information.
FUNDING:
$ 200,000 - FRDAP Grant # 5 Funds were provided in the budget.
RECOMMENDATIONS:
The Parks and Recreation Department recommends that authorization be given to piggyback off
of The City of Clewiston Bid # 02-03-11 for Irrigation Pump Station Replacements at Central
Winds Park in the amount of $ 35,886.02.
IMPLEMENTATION SCHEDULE:
,
The new Irrigation Pump Station will be completed within 60 days of approval.
ATTACHMENTS:
Attachment #1
Hoover Pumping Systems Proposal.
COMMISSION ACTION:
f'/.., r....'
.OVER
ATTACHMENT #1
REVISED
PROPOSAL 5497-11989
January 30, 2004
PUMl'lNa S'tSTl!:M$
Company: City of Winter Springs
Attention: Steve Rictlart
Tel: 321~303-7215
Fax: 407-.327-4763
RE: City of Winter Springs Central Wiinds Pk Replacement - lnigation Pump Station
Hoover Pumping systems will fumish one Hoovet model HC2-3OJ10PD460I3-ALQ-Z
pressure demand irrigation pump system with (2) - 30 horsepower three phase centrifugal pumps
delivering an estimated 500 total GPM at the station discharge at 10' lift with the following features:
· 10 horsepower centrifugai jocfc;ey pump with pressure sensor In the volute
· U.L. listed self-diagnostic pressure startlflow retirement control panel assembly in NEMA 4 enclosure with
through door disconnect, individual pump fuses, IEC starters and overload, elapsed time meters, status
indicator lights for low pressure, loss of prime, pump thennal. service required and counters for time in each
mode- hand or automatic, and number of occurrenceS for each shutdown, transient surge protection
· Reduced voltage starters for alllTlotors
· 4" control valve with pressure re.:tucing and sustaining pilots, limit switch, pressure gauges up and
downstream of the control valve and large capacity disk fitter and 2" parallel control valve for jockey
· (2)- 30 horsepower centrifugal pumps providing 250 GPM each @ 240 TDH with thermal :sensor In the volute
and Tl::FC motor
· Galvanized steel mounting skid, discharge header, butterfly valve at header and each pump discharge, 47
gal. 125 PSI hydro-.pneumatic fiberglass pressure tank with isolation valve and hose btb
· Automatic bypass of pump station when inlet reclaim water pressure is adequate for Irrigation use
· InstallS" PVC pipe up to 120' to lake, above ground, with rip-rap/rebar supports, flanged swing check valve
and 316 stainless steel suction screen
· InstaU au galvanized pipe to existing reclaim line with swing check valve
· Instan 6" diameter galvanized roll groove discharge pipe and fittings to below grade with 30" PVC adapter for
main line tie-in by Hoover
· Install customer supplied back flelW preventer. Customer to Instruct Hoover as to local codes for installation.
· 1-year parts and labor warranty
· One service call to perform initial Startup and Calibration
Lump Sum Price: $35,886.02
Note: Efecb1cal Hrvice, wncrvte pad, ,.dditiomtl suction ~e, and pennits are not Included. Customer to
remove one side of eeeurity fence for aCC8S$ to pump station. Back:flow protection of water source not included. .
Sales tu not tncIuded. F.O.B. Winter Sprfngs.
Please caR if pump performance or other features do not meet project criteria. Thank you for your consideration.
Sincerely,
HOOVER PUMPING SYSTEMS
~ k.~
George Newman
2620 N.W. 15th Court. Pompano Beach, Florida 33069. (954) 971-1350. Fax (954) 975..0791