HomeMy WebLinkAbout2003 08 11 Regular D Final Engineering/Site Plan and Development Agreement Amendment for an Automotive Repair Shop
COMMISSION AGENDA
ITEM D
Consent
Information
Public Hearin
Re ular
X
//~j
/Dept./~
August 11. 2002
Meeting
MGR. K
REQUEST:
Community Development Department requesting Commission consider and approve the final
engineering/site plan and development agreement amendment (building elevation/architectural
rendering) for an automotive repair shop on a 1.36-acre parcel along the south side of SR 434,
just east of the entrance to Tuskawilla Trails. Signage will be addressed separately, at another
time.
PURPOSE:
The purpose of this Agenda Item is to request that the Commission approve the final
engineering/site plan for a two phase site plan with a 3,000 square foot (foot-print) automotive
repair shop and an adjacent 3,784 square foot (foot-print) future building along SR 434, within
the Town Center and amend the existing development agreement. The amendment to the
development agreement consists of a modified building rendering (flat roof). The automotive
building is planned to have office use on the second floor,
APPLICABLE REGULATIONS:
Section 166,021, Florida Statutes,
Chapter 9, Land Development.
Town Center District Code,
Binding Development Agreement.
August 11, 2003
Regular Item D
Page 2
CONSIDERATIONS:
The 1.36 acre site was annexed into the City on June 11,2001 (Ordinance No. 2001-34). On
June 25,2001, the City amended the Future Land Use designation from Seminole County Office
to City Town Center. On September 10,2001, the City adopted Ordinance No. 2001-48,
amending the zoning from Seminole County A-I to City Town Center.
A special exception was approved for an automotive repair shop on October 22, 2001. A
development agreement, addressing allowable uses, hours of operation, the building fa9ade,
signage, vehicle storage and screening, and pollution and other environmental concerns, was
approved at the June 10, 2002, City Commission meeting and executed on June 19, 2002 (please
see Attachment A). The site plan has been designed pursuant to that development agreement,
although the applicant wishes to modify both the building elevation and signage from that which
was depicted in Exhibit "B" ofthe development agreement. Therefore, exhibit "B" must be
amended if the building is to be built as proposed.
The treed site currently contains a wood frame residential structure that will be demolished as
part of the site work. The existing well and septic systems must be properly abandoned (except
that the well may be retained ifit is to be used for irrigation). No wetlands or floodplain issues
apply to the site. The 13,911 square foot storm-water pond, located at the rear of the site, is
designed to capture the 100-year storm event, rather than the 25 year storm. Any overflow at or
above and beyond the 100-year design storm event will discharge via weep-holes in the wall into
the unimproved 30 foot wide right-of-way that exists behind the site - between the site and the
adjacent Tuskawilla Trails mobile home community.
The site is proposed in two phases. The first phase will include all of the site work, including a
two-story building with a maximum of 5 automotive bays (3 for automotive repair and 2 for
express lube service) on the 3,000 square foot first floor and office uses on the second floor.
Neither the Town Center Code nor the development agreement requires an actual second floor,
although the building is required to have the appearance of having two floors. The second phase
consists of a 3,784 square foot building (footprint) is proposed for the future. As part of the
phase one.improvements, a wall will temporarily cover the portion of the frontage where the
phase two building will eventually be constructed.
A two-way 24 foot wide frontage road is proposed along the SR 434 frontage (please see SR 434
Frontage Road requirements in the Town Center Code). A cross access easement is depicted on
the plans and must be provided prior to issuance of a Certificate of Occupancy. One curb-cut
onto SR 434 is proposed, at the northeast comer of the site, connecting both the frontage road
and the other on-site vehicle accommodation areas with SR 434. Since this site is temporarily
isolated (until the adjacent properties along SR 434 develop), 90 degree parking will be allowed
along the frontage road, but only as a temporary measure - at least until the adjacent property to
the west develops. Both parking configurations are depicted on sheet C-2. One parking space is
lost in the conversion from 90 degree to angle parking. The Town Center Code requires either
2
August 11, 2003
Regular Item D
Page 3
parallel or angle parking on frontage roads. The plan depicts a total of 38 initial parking spaces,
with 37 when the frontage spaces become angle parking.
FINDINGS:
1. The site is within the City of Winter Springs, has a Town Center Future Land Use
designation, and is within the Town Center zoning district.
2. The proposed final engineering/site plan is consistent with the existing development
agreement, the Town Center Code, and Comprehensive Plan (amend Exhibit "B" in the
development agreement to approve the revised building fayade and roofline).
3. The existing development agreement addresses the City's primary concerns to protect the
adjacent land uses from the potential problems associated with a wrecker service and automobile
repair shop, providing for reasonable use of the subject property.
4. The proposed building elevation/architectural rendering and roofline are contingent upon
Exhibit "B" to the development agreement being amended to incorporate those changes. Signage
will be addressed separately.
5. The 90 degree parking in front is only temporary and must be changed, as depicted on the
plans, to angle parking, when the adjacent site to the west is developed. A cross-access easement
must be conveyed to the City, for the 24 foot wide drive lanes area in this front area, prior to
issuance of a certificate of occupancy for this site.
RECOMMENDATION:
Staff recommends that the City Commission approve the attached final engineering/site plan and
amended Exhibit "B" to the development agreement (e.g. building fayade and roofline).
ATTACHMENTS:
A Development Agreement.
B Proposed new Exhibit "B"
C Final Engineering/Site Plan
COMMISSION ACTION:
3
111I1..... I .11........1..1.
@
Prepared by and Return to:
Anthony A. Garganese, City Attorney
BrMYn, Ward, Salzman & Weiss, P.A.
225 E. Robinson Street, Suite 660
P.O. Box 2873
Orlando, FL 32802-2873
Parcell. D. No. 36-20-30-502..()Q()()..()Q10
ATTACHMENT A
MARYANNE MORSE, a..ERK OF CIRCUIT COURT
SEMIt<<U axmv
BK 04450 PG 0328
CLERK'S # 2002902560
RECORDED 07/01/2002 04:21:36 P"
RECORDING FEES 69.00
R€CORDFJ) BY S O'Kelley
BINDING DEVELOPMENT AGREEMENT
Lq~
THIS BINDING DEVELOPMENT AGREEMENT is made and executed this I
day of ~~ 2002, by and between the CITY OF WINTER SPRINGS, a Florida
municipal corporation (herein referred to as the "City"), whose address is 1126 East State
Road 434, Winter Springs; Florida, 32708, and the owner of the subject property, JOSEPH
M, MIRANDA and ZELIA M, MIRANDA (herein referred to as the "Owner"), whose
address is 1417 Lambert Street, Deltona, Florida, 32725.
WITNESSETH:
WHEREAS, Owner owns certain property located in the City of Winter Springs,
Florida, Town Center District, and legally described in Exhibit "A," which is attached hereto
and incorporated herein by this reference (herein referred to as the "Subject Property");
and
WHEREAS, the City Commission at its regular meeting on October 22, 2001,
approved a special exception. to allow an automotive repair facility at the Subject Property,
subject to the seven (7) conditions set forth in the City Commission agenda item for the
special exception and also subject to the approval of this development agreement between
the City and Owner; and
1
,. 1 Lt: NUPl ~UO~'902S60
OR BOOK 04450 PAGE 0329
WHEREAS, the City Commission of the City of Winter Springs finds that this
Agreement is consistent with the City's Comprehensive Plan and land development
regulations and is a legislative act of the City Commissi.on of the City of Winter Springs;
and
WHEREAS, the City Commission further finds that this Agreement promotes the
public health, safety, and welfare and is consistent with, and an exercise of, the City's
powers under the Municipal Home Rule Powers Act, as provided in s. 2(b), Article VIII of
the Florida Constitution and Chapter 166.021, Florida Statutes, and the City's police
powers.
NOW THEREFORE, in consideration of the mutual covenants and mutual benefits
herein contained, the parties agree as follows:
1. Recitals. The foregoing recitals are hereby incorporated herein by this
reference.
2. Authoritv, This Development Agreement is entered into pursuant to the
Florida Municipal Home Rule Powers Act, and the Code of Ordinances of the City of
Winter Springs.
3. Representations of Owner. Owner hereby represents and warrants to City
that Owner has the power and authority"to bind the Subject Property and execute, deliver
and perform the terms and provisions of this Development Agreement, has an equitable
or legal interest in the title to the Subject Property, and has taken all necessary action to
authorize the execution, delivery and performance of this Development Agreement.
2
FILE NOM 2002902560
OR BOO<< 04450 PAGE 0330
4. Approval of Special Exception. The City hereby reaffirms that a special
exception to allow an "automotive repair shop" has been approved by the City commission
on October 22, 2001, for the Subject Property, subject to the terms and conditions of this
Agreement. Owner acknowledges that if this Agreement is ever terminated, the special
exception shall be deemed null and void and the use of the Subject Property as an
automotive repair shop shall no longer be permitted, unless otherwise approved by the
City Commission. The automotive repair shop shall be strictly limited to only routine
service as more particularly described herein.
5. Town Center Acknowledgment, Owner hereby acknowledges that the
Subject Property is located in th"e Winter Springs Town Center and is subject to certain
unique regulations. These regulations are designed to ensure that all structures and uses
of property located within the Town Center are developed and maintained in a high-quality
"j
condition that promotes the Towil Center vision and character set forth in the City's
Comprehensive Plan and Code of Ordinances. Owner also acknowledges that any use
of the Subject Property that is inconsistent with this Agreement and the Town Center
regulations is detrimental to the public health, safety and welfare of the citizens of Winter
Springs. Therefore, Owner hereby agrees to abide by all provisions ofthe Town Center
Zoning Code and Comprehensive Plan provisions and all discretionc;lry "City approvals
granted under said Code and Plan, as may be lawfully amended from time to time.
6. Use Restrictions, Owner agrees to fully comply with the following use
restrictions on the Subject Property:
3
FILE NUM 2002902560
OR BOOK 04450 PAGE 0331
6.1 Hours of Operation/Noise. The hours of operation of the automotive
repair shop shall be limited to the hours of 7:00 a.m. to 7:00 p.m., Monday through
Saturday. Owner shall take all reasonable and necessary steps required by the
City to minimize noise impacts on surrounding properties. No activity on the
Subject Property shall produce any unreasonably loud, disturbing, and/or raucous
noise, audible from surrounding properties, at any time. Emergency towing is the
only commercial activity allowed at the Subject Property between the hours of 7:00
p.m. to 7:00 a.m., Monday through Saturday and all day on Sunday.
6.2 SiQnaQe. Signage must conform to the Town Center requirements
and shall be limited to that depicted on Exhibit "B," which is, attached hereto and
incorporated by this reference.
6.3 Vehicle Storage/Screening. Vehicles awaiting routine service or
I OJ
repair must be stored in the rear of the site and not be visible from the public rights-
of-way. Garden walls, fences, or hedges may be used to screen vehicles from'
public view. A 6-foot tall masonry wall shall be constructed and maintained along
the entire rear boundary of the Subject Property. The height of said wall shall be
measured from ground fevel and the masonry materials and design of the wall shall
be subject to City approval. The Subject Property shall not be used as a towing
storage area (no wrecked' or stored vehicles will be allowed). There will be a
reasonable limit to the time a vehicle may be kept at the Subject Property. Tow
trucks or similar-type vehicles shall not be stored or parked overnight on the
Subject Property.
4
FILE NUM 2002902560
OR BOOK 04450 PAGE 0332
6.4 Use Restrictions. On-site work shall be limited to minor automobile
,'~ .
repairs and express lube'. There shall be no retail sales of automobile parts or
accessories. Allowable minor automotive repairs uses include express lubrication;
other automotive fluid changes or additions; tune-ups; timing, carburetor, clutch and
other various adjustments; changing clutches, head gaskets, shock absorbers,
struts, starters, alternators, water pumps, radiators, hoses, belts, windshield wipers,
and similar other routine service items. Major engine or transmission work (e.g.,
overhauling or changing engines or transmissions), frame straightening, paint
and/or body work, and similar major service items shall be strictly prohibited.
6.5 BuildinQ. The building located on the Subject Property shall b~.
constructed to be 2-story in appearance, or in fact, with all four (4) sides of the
building, as well as the wall(s), substantially consistent, architecturally, with the
)
facade substantially in conformance with Exhibit "B," which is hereby incorporated
herein by this reference. The building may house a maximum of five (5) "service
bays," three (3) of which will be used for minor automobile repair work and two (2)
of which will be used for express lubrication. Owner may construct one residential'
unit on the second floor of the building, subject to all applicable building and
life/safety codes. The building shall be provided with an awning or awnings on the
front, consistent with the awning specifications set forth in the Town Center District
Code.
6.6 LandscapinQ. In addition to the normal exterior building landscaping.
the final site plan shall include a landscape plan with landscaping and trees on the
5
OR BOOK 04450
PAGE 0333
interior of the Subject Property. Owner shall maintain the landscaping at all times
by retaining a competent and qualified professional landscape maintenance
company.
6.7 Pollution and Other Environmental Concerns. Owner shall fully
comply with all applicable local, state, and federal environmental regulations and
laws governing noxious fumes and the disposal of waste materials. Fumes and
obnoxious odors generated by the automotive repair shop shall not affect the
surrounding properties and shall be minimized to the maximum extent possible.
Stormwater management, motor oil tanks, and other environmental considerations
shall be adequately addressed to the City's satisfaction during the site plan review
process.
6.8 Expiration. If construction of the automotive repair shop is not
substantially completed during the course of two (2) years from the date that this
Development Agreementis executed, as evidenced by Certificates of Occupancy,
this Development Agreement shall expire. The two (2) year period may be
extended by the City Commission, if due to difficulties beyond the Owner's control
and despite a good faith effort by the Owner, construction is delayed.
7. Successors and Assigns. This Development Agreement shall automatically
be binding upon and shall inure to the benefit of the successors and assigns of each of the
Subject Property.
6
FILE NUM 2002902560
OR BOOK 04450 PAGE 0334
8. Applicable Law. This Development Agreement shall be governed by and
construed in accordance with the laws of the State of Florida and the City of Winter
Springs.
9. Amendments, This Development Agreement shall not be modified or
amended except by written agreement executed by all parties hereto and approved by the
City Commission of the City of Winter Springs.
10. Entire Agreement. This Development Agreement supersedes any other
. agreement, written or oral, and contains the entire agreement between the parties as to
the subject matter hereof.
11. Severability. If any provision of this Development Agreement shall be hele
to be invalid or unenforceable to any extent by a court of competent jurisdiction, the same
shall not affect in any respect the validity or enforceability of the remainder of this.
,. ",
Development Agreement.
12. Effective Date, This Development Agreement shall become effective upon
approval by the City of Winter Springs City Commission and execution of this Development
Agreement by all parties.
13. Recordation. Upon approval by the City of Winter Springs City Commission
and execution of this Development Agreement by all parties, this Development Agreement
and any amendments hereto shall be recorded by the City in the public records of
Seminole County, Florida, and shall run with the land.
14. Relationship of the Parties. The relationship of the parties to this
Development Agreement is contractual and arm's length. Owner is not an agent of the City
7
FILE NUM 2002902560
OR BOOK 04450 PAGE 0335
for .any purpose. Nothing herein shall be deemed to create a partnership, or joint venture,
or principal-agent relationship among the parties, and no party is authorized to, nor shall
any party act toward third persons or the public in any manner which would indicate any
such relationship with any other party.
15. SovereiQn Immunity. Nothing contained in this Development Agreement
shall be construed as a waiver of the City's right to sovereign immunity under Section
768.28, Florida Statutes, or any other limitation on the City's potential liability under state
or federal law.
16. City's Police Power. Owner acknowledges and agrees that the City hereby
reserVes all police powers granted to the City by law. In no way shall this Development
Agreement be construed as the City bargaining away or surrendering its police powers.
17. Interpretation, The parties to this Development Agreement acknowl~dge
)
and agree that all parties have participated equally in the drafting of this Development
. Agreement, and no party shall be favored or disfavored regarding interpretation of this
Development Agreement in the event of a dispute between the parties.
18. Permits, The failure of this Development Agreement to address any
particular City, county, state and federal permit, condition, term or restriction shall not
relieve Owner or the City of the necessity of complying with the law governing said
permitting requirements, conditions, term or restriction.
19. Third Party Rights, This Development Agreement is not a third party
beneficiary contract, and shall not in any way whatsoever create any rights on behalf of
any third party.
8
FILE NUM 2002902560
OR BOO~ 04450 PAGE 0336
20. Specific Performance. Strict compliance shall be requireq with each and
every provision of this Development Agreement. The parties agree that failure to perform
the obligations established in this Development Agreement shall result in irreparable
damage, and that specific performance of these obligations may be obtained by suit in
equity.
21. Attorneys' Fees. In connection with any arbitration or litigation arising out
of this Development Agreement, the prevailing party shall be entitled to recover
reasonable attorney's fees and costs through all appeals to the extent permitted by law.
22. Future RezoninQs/Development Permits, Nothing in this Development
Agreement shall limit the City's authority to grant or deny any future rezoning or
development permit applications or requests, or the right of Owner to apply for or oppose
any future rezoning or development permit application subsequent to the Effective Date
('
') of this Development Agreement. In addition, nothing herein shall be construed as granting
or creating a vested property right or interest in the Subject Property.
23. Force Maieure. The parties agree that in the event that the failure by either
party to accomplish any action required hereunder within a specified time period ("Time
Period") constitutes a default under the terms of this Agreement and, if any such failure is
due to any unforeseeable or unpredictable event or condition beyond the control of such
party, including, but not limited to, acts of God, acts of government authority (other than
the City's own acts), acts of public enemy or war, riots, civil disturbances, power failure,
shortages of labor or materials, injunction or other court proceedings beyond the control
of 'such party, or severe adverse weather conditions ("Uncontrollable Event"), then
notwithstanding any provision of this Agreement to the contrary, that failure shall not
9
FILE NUM 2002902560
OR BOOK 04450 PAGE 0337
constitute a default under this Agreement and any Time Period proscribed hereunder shall
. .
be extended by the amount of time that such party was unable to perform solely due to the
Uncontrollable Event.
24. City's Riqht to Terminate Agreement. Failure by' Owner to perform each
and every one of its obligations hereunder shall constitute a default, entitling the City to
pursue whatever remedies are available to it under Florida law or equity including, without
"'-
limitation, an action for specific performance and/or injunctive relief or alternatively, the
termination of this Agreement. Prior to the City filing any action or terminating this
Agreement as a result of a default under this Agreement, the City shall first provide the
Owner with written notice of said default. Upon receipt of said notice, the Owner shall be
provided a thirty (30) day opportunity in which to cure the default to the reasonable .
satisfaction of the City prior to filing said action or terminating this Agreement. If thirty (30)
, "
days is not a reasonable period in which to cure the default, the cure period shall be
extended to a reasonable cure period mutually acceptable to the City and the Owner, but"
in no case shall that cure period exceed one-hundred twenty (120) days. Upon termination
of the Agreement, the Owner shall immediately lose all rights and privileges granted
hereunder.
IN WITNESS WHEREOF, the parties have executed this Development Agreement
as of the date first written above.
ATTEST:
---- -
By:
PAUL p, PARTYKA
Mayor
10
~~#
b~"/.A-/;d d? ?Z/f./%ir
FILE NUM 2002902560"
OR BOOK 04450 PAGE 0338
OWNER:
By: ~ fY1~.t1~/1{~,
4O~PH M, MIRANDA
Date ~~~/ D2
By: ~ (2,0. ~~\r"'h.~ a-
LIA M, MIRANDA
Date:
6-lq-o ~
'l daytJL,
o has produced
Th oregoing instrument was acknowledged before me this
fSl02, y Joseph M. Miranda, [J who is personally kn n to I or
~ -,S3 /jq 3 5 3 O..!:J-o-~ () as identifi tion.
The oregoinginstrument was acknowledged before me t is
J.002, rJ ~elia M. Miranda, [ ] who is persona.IIY k. wn t I or [
r::L}r{ bE CJ93 5-3 hbt}-IJ as ident' tion.,
\
..,~~ Sylvia P Denson
* Y;ijijJ * My Commission CC870502
~W1~
'It" ".... Expires November 6, 2003
(S EAL)
STATE OF FLOR
COUNTY OF (",
(SEAL)
.,;,... ""~ Sylvia P Denson
* *My Commission CC870502
~ .
.>'.",..... Expires November 6,2003
oJ
daY~,
o has produced
(p, OJ
,
11
. .
, EXHIBIT "Au
Legal Description
.....
FILE NUM 20029025&0
OR BOOK 04450 PAGE 0339
FILE NUM 2002902560
OR BOOK 04450 PAGE 0340
-\
,
\
\
2.0....
2/\
:;.. ~..
'211
~AcHE'TR
V.O
G
a1.01
LEGA.L DJi:S~RI~JJON
PROPERTY FOR WINTER SPRINGS AUTOMOTIVE
Beginning at the most Easterly comer of that part of Dlock "B" of D. R. MITCHELL'S
SURVEY OF THE LEVY GRANT, as recorded in Plat Book 1, Page 5, in the office of
the Clerk of Circuit Court of S croino Ie Couoty~ Florida, lying South and West of the
paved road leading from Sanford to 9viedoj thence along the Southwesterly side of the
paved road North 38 degrees 45 minutes West 1586.00 feet to a concrete monument West
200.00 feet; thence South 51 d\:grees 15 minutes West 291.30 feet to t.he Southeasterly
side ora dirt road; thence Sqltlh 22 degrees IS minutes East 208.lW feet; thence North 51
degrees 15 minutes East 351.10 feet to the point of beginning. Less road right of way
described in Order of Taking recorded in O. R. Book 2803, Page 1023.
EXHIBit "B"
Signage/Facade
FILErNUM 2002902560
OR BOOK 04~50 PAGE 0341
"'
FILE NUM
OR BOOK 2002902560 .~ .
011450 \
PAG6-d342
S.R. 434.
Front l::acad p-' ,
. e. . aCIng
(PRELIMINARY)
----I
,(
~
. ~'1'
...J'.
/( )
r
/-
~.-
I
1---
I
_J.
\ .
~;
\
1
\
I
\
\
I
\
I
I
!
/..J
...
\
. i
"~.:.J'l
,I.
I
.,
A...
\
\.
.
~
~'
. ..-' ",
~.
..,t ,..,.-'
. . " '" . '-?'%'--~.. ,."
., .--:.,.... ,,-;t~' .," .
'"
"~."
~
. .......,.
. _" .~,. ." ~.;,oo /...' ..,..,;.. .;
.' - - ." ,,.,..' .....~....' .~ ..."....,
. . ,... " / .,' _," ..,;;. ." ,r
. . I"~ .',.... ..,/ >'
., .... . ,.".
'.
~,
o
-'
~(!'
:nZ
~z
:nZ
_4-
-:- c.:>
:::l en
>-0:::
J-- 0 '.,
::i '""- .'
05 '
a
':i
)
: :.
. .
i '
I
, :
f '
l ,"
Ii
MUg Ut:l U..::l U:::I:.lC:P
.JtlW8.H
407-622-9325
P, 1
Richard J_ Uytdewilligen
Cb0f : ~\ [ c'A-
697 Balmoral Road
Winter Park, Florida 32789
August 8, 2003
Honorable Mayor and Commissioners
City of Winter Springs
21 Tarpon Circle
Winter Springs, Florida 32708-4111
Phone: 407-327-5956
Fax: 407-327.4753
Subject:
August 11, 2003 Commission Agenda - Item "D"
Mr. Miranda's Development Agreement
Honorable Mayor and Commissioners:
This month, I , Richard Uytdewilligen, will be closing on my purchase of the one (1) acre parcel
ofland adjacent to the western boundary of Mr. Miranda's property, between Tuskawilla Trails
and across from City Hall.
As a new owner of "Winter Springs Town Center property", I strongly oppose amending Mr.
Miranda's existing development agreement to modify the building rendering to allow for a flat
roof with mechanical equipment (AC, etc.)on top.
I am considering various concepts for development of my property which may include a three (3)
story building height. My concern is the unsightly appearance of a neighboring flat roofed
building with mechanical equipment.
I respectfully request that the Mayor and Commissioners not amend the existing development
agreement, in any way, including the building facade.
I am presently out of the country at this time and I am unable to attend this meeting, but would
greatly appreciate your consideration of my request not to amend the development agreement.
Sincerely,
i
fli
ail
it~
IJI
Ht
lal
III
!!j
11- !
i s
iIi
I I
hI
J!I
ai
ill
II
1'1
fJ~
-II
!)i
i I
a J
itl
I,!
'11.1'
III
~h
ft,.
It I
ill
lilS
fl1
J.
aJ
il~
11~
,Ii
! -I
0:1
II
if I
ia~
Jill
fit
jJ,!
1.1'.
lit
lit
-.I
Iii
111
eJj
tSl
~It
~1i
,OJ!
jl.
ISIs
! 1
tit
it';
l! !
1~1
., t ~
~~I
-II
l~i
!I~I
iJjJ
f S fog
':jJii
illlJ
Iht
J1iff
d .1
Ill.
!fiJ
~ J2
!o~1
nCI
Ht
lIlt
1ft ~J
!it~
JIJ}
:iJJ
-S!Jis
Jill
1111
sEb-3]'-8" ------------------------------ r-,
TOP OF KEYSTONE I-'i
i ~
I
I--
EL,31'-8"
S T.O, SEMI-ciRCLE
4'-0"
-
4'-0"
-----.- -~-T_-=
1-=
;;j
S EL. 2tr-O" _ _ ~
T.O. PARAPET
S EL.2S.~ -- r- ---------- --------------------------------------------------------- -------~
T.O, ROOFl:""" r
~I ??'.tIP
@ DEDUCT ALTERNATE #2
3118". 1'-0"
~
-- ,-I
~ 'j
~!
~~~---------------
TOP OF KEYSTorE
sEL3j'~ __
T.O, SEMI-CIRCLE
S EL 2~-O" _ _
T.O. PARAPET
S EL, 2~-~ _ _ I:
T,O. ROOF
S EL, ~-10" _
T.O. FRAME
~
S EL, 19'-10"
B.O. FRAME
b
9"'
i>1
S EL, 1-'-0" _
T,O, FRAME
~
[I}-~
~
(:)
9"'
S EL, 'Z-O" _
B,O. FRAME
-.. EL. a-O"
\J/I
.--- --
~.- .......~,
~
4'-0"
_.
-
','
.-
@ III
/1
j~
/,
!
I
I
r
I
I
/ ./ I
=")
,
,
I
_J
-
@
/
1
I
. .'.
"
I
1
3116". 1'-0"
SIDE ROAD ELEVATICPN
_EL, 35':8"_ _ _
&- T.O. KEYSTONE
EL. 33'-8" I r-
~ T.O. SEMI-CIRCLE '
t-
S EL. 30'-0" __
T.O. PARAPET
:
SEL.2~~ __
T.O. ROOF
I
I
I
I
"-
'----------
S EL. 22'-10" ---'i;-
T.O. FRAME
b
9"'
.'
II)
~~. 17'~
B.O, FRAME
.
S EL. 15'-8" _ 2
T.O. BANDING \..
~ EL. 12'-0" __
T.O. CMU (
~~.11'~~
B.O, BANDING
'~~~
~ -
\ 'If-.ft. ~ 4/
\ ~?~
____m___ ~ ____ ______ _ 1_ /
---~ . _;:.,/-_n_ __________ __n_________
~ ~ ~
~
---
1
,~
HI]
,
@ ''-;
D,
, ,
i
@ ///
, '/
I 1
@ 1:'/
6
_______-Hl
~
/v
I.-
d_ ~-1
".__:.... __l..~_ ___ _HI..; .". .__'___. ..__.__. ___~
" ,
__~ _ "'T." _1..._ . ...... _ _ ..<on ~_'_'_ _.,.
H1J
: . . , . __ ....1.. _,. ..:...._., _ ._l _1.__ r ..1
, i
-..!_._.~_. ~..~._----~.._..!..._.--,_._~_.,.------_.---"-._.__..._-,
. "
..... EL a..f1'
'"
o RIGHT SIDE ELEVATION
3118" · 1'-0"
1,
.
l'
,
,
.
.
f1i\~ Y
~~ .1
! \ C>>~ G---IL I
I \ rl31 1:-- t ' -\ \J; ,
! ~~r\~l_._--vr~ I
- i I \ ~ EST./ II:' 1 /
, I ')nn~ 'I
I I ...."''''...
------------ ,- ----1----- r------ L-----L------------ --- ----f----- ________
~I A * ~
@ /, I @ j,{ @/ @ .'> I
i i i ,,/ i
I
MATERIAL LEGEND
[K] MATERIAL DESCRIPTION COLOR & FINISH
ITJ %- STUCCO, INSTALL CONTROL JOINTS WHERE SHOVVN AS SELECTED .
APPROVED BY O'NER
~ ,.- DOVVN SPOUT AS DETAILED AS SELECTED .
APPROVED BY O'NER
[!] UNE OF METAL CAP FLASHING AS SELECTED .
APPROVED BY O'NER
~ DECORATIVE MOULDING, SEE SHEET AS,1 AS SELECTED .
APPROVED BY O'NER
[[] SIGNAGE BY OTHERS AS SELECTED .
APPROVED BY 0V\t.ER
00 DECORATIVE LOWER AS APPROVED BY O'MIIER AS SELECTED .
APPROVED BY O~
[I] 8" SPUT FACE CMU AS SELECTED .
APPROVED BY OWER
[!] NIGHT KEY DEPOSIT AS SELECTED .
APPROVED BY O~
[[] 8" X 18" OVERFLOW SCUPPER
~~~------------------------------------------
T.O, KEYSTONE
EL. 31'-8"
~ T.O, SEMl-CiRCLE r-
"
~
~ EL. 2tr..cr.
T.O, PARAPET
~ EL.2~4" ___'--__
: T.O. ROOF
S EL. 2?-10" __
. T.O, FRAME
~ EL,1'-10" __
B.O, FRAME
.s
~ EL, 1'-0" _
T,O, FRAME
~
'.-
!I}- "
~
l?
(:)
9"'
i
,
ffi-r'-
~ EL, 'Z:O"~ _ ~I.- ~
B.O, FRAME
-.. EL, ry-f1'
'-Ill
~ EL ~-8" _ _ ,--
T,O, SEMI-CIRCLE
~ EL 30'-0" __
T.O. PARAPET
i
b
-
iQ
EL,12"-f1' J C
~,O.CMU .1"[
H_1" .
ill, _:_:
!? I~
N i
~ .. "'--1'-
--'-.-
____.L_
i
_.J l'
-.. EL, ry-a
""
i
--1--
4'-f1' _~ 7 / / "\ rl1J
,1 !
'----~_._-_.._-- --.-.-.--,--..-, =.
"-- /
~: ;~~.L:- --~~ r~I~i-~-i~~~:__~-~ _:~,'_:~u iuJ -~-' --~'--;-.IJ~.'. -._ .:~~-~--~.-:~~t--j-}-~.T-:-~:'~. ,~:--l~r~'-' ..:-J~~~-_~:-i:' -~'!'~!-~-.-~':- L_-~::;-~' -
i ' . 1 'I
;-2~~c-~.L. ,;/ :'/.-/ J~ ~'~-, ! ':,: / ,>>' ~!~'~ ,/:,
! H' '~ i / L:! ~:T:I
~_:-~-. ~/ .' I I _:.L,
;. q. ;), ',' ' : ~~ :~~ /, i l : i
'v I
! " :~':~J-'~"_~~ '.:L:.:.:
c:::j
~
~
4'-2"
S EL, 34'-0" ~
T,O. PARAPET- 3
~ EL 3fJ-fr __
T.O. PARAPET
f
3'-9"
f
I
-------~------~---- -
/HHl
~
" ki>11
l/
14
~
~
I
I
@ //'
'''.'
,. I
,/ @
I
I Vi I
!
I
I
I
I /" -f131
Ill~
I
I
I
I ! I
I I I I I
1,- --!
1,1 i@
II
III
J--
t
',t @
.I
/~/
,
I
!
/~
~
~i3l
'"
I
(
.
r-----WtNl~~R-S...~ -
I: . t':
t
I
,
I
@
@
I
!
I
!
I
:
o FRONTAGE ROAD ELEVATION
3118" · 1'-0"
,........J
(~ .- -',----'-
-;-...l--r+-"UT I.....T-. _;_J- :_-l.._: -.--1---.--- ..-
r I ' ~-.-.._:..-,'----;-....'.,-..-.J,...-I.- .._-
L::~_.:~~~-l~ ';~j-i:J.'.:;~. ......, l-~ ,"
c::::I
MA TERIA~L LEGEND
[K) MATERIAL DESCRIPTION COLOR & FINSH
[Q] INSULATED EXTERIOR METAL DOOR SPEC SECTION 8800 AS SELECTED.
APPROVED BY O'MIIER
ff1] OVERHAED SECTIONAL DOOR WHT UTES AS SELECTED &
APPROVED BY OV\rt4ER
~ STOREFRONT DOOR WITH TEMPERED GLASS AS SELECTED &
APPROVED BY OV\rt4ER
~ FABRIC A~ING AS SELECTED &
APPROVED BY OV\rt4ER
~ ALUMINUM SUN LOWER AS SELECTED &
APPROVED BY O'MER
~ ALUMINUM STOREFRONT SYSTE", AS SELECTED &
APPROVED BY O'MIIER
..
~
~
.
""!lI)
.19
f!}
Q;
____________________EL,~~
3'-9" 4'-2" 4'-2" T.O. ARCH
r - - - - EL. 32'-0" foil
I T.O. PARAPET
j --- - _ _ EL. 3!1-O" 0
I--ill T.O. PARAPET
1
f
I r
I
!
___ _~______ EL.2~4"0
L1Iil T.O. ROOF
r-----~~
i~ ____EL.2?10"
'" ~--~/~ 1\ ut8\ T.O. FRAME-0
@/,' ~
/ -GJ 16\
/ I-~ - EL. 1..7'-0" 0
B.O. FRAME
r~--GI
~-----rl---~=:~
.... , :_, --... . ~~ _ _ _ ~L. ~
, l. u._ '-- .-: ~ T.O.FRAME
~
, '/>
@ ,/
NGS-AltT-o-MOf
I
.. ........ - .
... i
434 ,_,_,...J. - ..
~
, '," -ill
.-/
-.... _.
:
,
,
,
, ..1
. 'r" I._~.
, ,
>i
I' -. -- - .. . - ..1 -' -- -
i__ _.~ . r - I
_~_ ._'~_.~ __>_. _.,- _. h u. __.. _____.
EL. 2'-8"
------~
B.O, FRAME
)121
/~
/
/
-
/,
,
.l u u
-
::;'-~-._';--IT-~h;..-~~_~.::;~..--.-.u-;'..~.'~-'~-~'''~' ' , ,- __,_ .-_;_T'-:':J:::~_' I_T';~
-.- ~ . _____ I __-1 ... ...._. ..._1 _ _ ._ .._ _ ...L ___
1,u__ _.1.. __..,__ L_,.; .__ .._..
-.... - :' - ~- - -
_. I ._ _ j
. ._. _. . h .. _.... _. '_
,
EL, a-O",...
'"
-_.. - -.--- - -.. --_. - -'- - -._- ---- -. --_. _._- - - - --_.. - - - _. -- - -- - - -- -- .- ----..-. -
~ r--ill rill r-ill EL. 28'-0"
I / / -- - T.O.- PARAP~
------- >-- L:.J__ >-----1-- .-@--- ------- ~---I~.- TOP-O';Rri':foIl
--'.- _ _EL, ~.10"0
~ T,O. FRAME
(w)
6'-0"
m..m m -- -.--.r-f3] .. 2
8'-fr ~ / f/':ii
., , 1"1
r ^ 11 I I
~
..
6'..(1'
;ill
~
.1
.--- -.. --- .-.-----.--------.
I till, r-oo
~.:2S-~----r------
T.O. ROOF r:tl.-
, ~
S EL, 22"-1cr \
T.O. FRAME- \
&-1;1.. 17'-9" _ _
B,O. FRAME ffi"(
~L.13'-10:112" ~ f-,L---_________
MEZZANINE
:
!
I
t--- - ! (, ' , ,'" ._ h" ~ ..., .'_',," :..' .... __.,' .LiL._.J "_'
------.-------------.--------- - _~IL~ -: ------.---------r------ ~. .~;-- ~ :: ----.-:.-:_ i -~: -~ ~":-_: .JI, I L~;~~:_ ~ ~ ~_:, --.. -~ - . - - --
, . . _r ~~,l~:-=~L-,~~ ~:_ :..
L ___~..______~rDJ__n___=. ~ .~ ~ I - - ]:;1. '[Q]~-:~--=;~~l~~~~-;;i ~-~~-:"?-~~~::~ _ ~=~-=__BJJ= ~=-.-_n=
c. .---.----..-m-rn--n.-.l~:/7 T ' , ,I~. LT1<:-;c::, T'.:,:::'=,"T-,'.'
t:::J[!J--l
f/ .0"
II
1
^i
I
I
/
rb I · I 1/
----- --~.-->------l---- -+--- --- ----~-l~- c--
I ~a1~'
I .I: J ,
I~) I--
:
I
,
I
,
!
-- ---
. ,
'/
,@
1
@ ~?I
,
@ /,1
@
I
I>
(
J
)
0. REAR ELEVATION
3118" :II 1'-fr
7
I=:J
EL. 35'-6"
- - ...........
TOP OF KEYSTONE
r- --___ EL.31~
T.O, SEMI-CIRCLE
!8)
,18\
, .I
I
_ _EL. 1~-10"0
B.O. FRAME
b
9"'
I
(w)
b
I
.
I---'r EL. 12'-0"0
T,O. GARAGE DR
-.-- ..-----.--------- --- -----------
I::" -.' -.. --
L-_
--_________ u________ ______.___.___
.- -c'.: _. h ..
:j I:
~
(:)
9"'
:1" .- 0"0 ."~i 'r ----. .--- -". .
i: '.'- d_ __""..:.....: j ~..,..:....:. ____ _ ,..,-1 !
~-------------- --.-
- -
! ,.' ... -- "....."" :.-:;".
L~~' _ .h. ,-~; tL, "__._ J,:...,~ .._ .__"
-------.----..------.-.-..-
ff1]
------------------------. .
ff1]
_u _ r-- __________u_____________ _________.____.__
" .
~
N..
r
EL U'.(J" ,...
.,
"
c... S ( 0 T T
I
Vl
ex:
u..J
"-\ 1\ C~ 1--1
I ~r E C~
~r Li 1\ E
Z
f-
ex:
<t
c...
423 South Keller Road
Suite 200 Orlando FL 32810
Phone: 407 660-2766
Fax: 407875-3276
Web Site: ScottArchitects,com
License No, SUlAACOO1155
.~_n.""'IloI"""AI'- ""'....
AI ....... ........ ........
CONSULTANT
PROJECT
WINTER
SPRINGS
AUTOMOTIVE
1135 S.R. 434,
Town Center District
Winter Springs, Florida
PROJECT NO:
02052
SEAL
IlECEI"ED
jUL 2 5 2003
sPRlNoe
CITY OF WlNT~~nInG
currenlr--
REVISIONS:
# DATE: DESCRIPTION:
DRAWN BY:
JH,FV
CHECKED BY: OJ
DATE: 11/19/02
SHEET:
ELEVATIONS
A3.1
SITE DEVELOPMENT PLANS
OF THE
t ItI!CI!IVI!D
\ JUL 2 ~ 2003
,
I CITY OF WINTER SPRINGeS
~ Current PI-*'8
...
CITY OF WINTER SPRINGS, FLORIDA
JUNE, 2003
I Sheet No.1
C-1
C-2
C-3
C-3A
C-3B
C-4
C-5
C-6
C-7
Description
Cover Sheet
Site Development Plan
Site utIty Plan
Off-Site Force Man Plan and Profile (1 of 2)
Off-Site Force Man Plan and Profle (2 of 2)
Site Gra. and Dr · Plan
Lift Station Detail
Construction Detail 1
Construction Detail 2
l Slrve
JOSEPH M. MIRANDA.
C/O INDUSTRIAL-COIMMERQAL STRUCTURES, INC.
933 LEE ROAD, SUITre: 400
ORLANDO, FLORIDA 32810
A T1N: TRISH DEBELL
TELEPHONE: 407-629-5431
Index Of Drawings
OWNER
UNIVERSAL ENGINEERING 5aENCES
3532 MAGGIE BOULEVARD
ORLANDO, FLORIDA 32811
A T1N: SHRI RAO
TELEPHONE: 407-423-0504
LOCATION OF PROJECT
ENGINEER
JOHN B. WEBB Ie ASSOCI A lES, INC.
925 S. DENNING DRIWE
WINTER PARK, FLORlmA 32789
AT1N: JOHN B. WEBS, P.E.
TELEPHONE: 407-62!2-9322
SURVEYOR
JOHN B. WEBB Ie ASSOCIATES, INe.
925 S. DENNING DRI"'E
WlNlER PARK, FLORIIDA 32789
A TIN. WlWAM F GR\;zm I. PSM
TELEPHONE: 407-622-9322
n::.
w
>
GEOTECHNICAL
Description :
Commencing at the most Easterly corner of that part of block "B" of O,R. MITCHELL'S SURVEY OF THE LEVY GRANT, as
recorded in Plat Book 1, Page 5, in the office of the Clerk of Circuit Court of Seminole County, Florida, lying South and
West of the paved road leading from Sanford to Oviedo; thence along the Southwesterly side of the paved road North 38
degrees 45 minutes West 1586,00 feet to a concrete monument for a point of beginning; thence continuing North 38
degrees 45 minutes West 200,00 feet; thence South 51 degrees 15 minutes West 291.30 feet to the Southeasterly side of a
dirt road; thence South 22 degrees 15 minutes East 208,80 feet; thence North 51 degrees 15 minutes East 351,10 feet to
the point of beginning.
SECTION 36, TOWNSHIP 208, RANGE 30E
EXISTING UTILITIES
LOCATION MAP
N,T.S.
'"'
WA lER & SEWER:
CITY OF WlNlER SPRINGS
110 N. FLAMINGO AVENUE
WlNlER SPRINGS, FLORIDA 32708
DOUG TAYLOR
407-327-2669
TRAFFIC:
SEMINOLE COUNTY TRAFFIC ENGINEERING
140 BUSH LOOP
SANFORD, FLORIDA 32773
DAVE MUNIZ
407-665-5679
ELECTRIC:
FLORIDA POWER CORPORA 11 ON
3300 EXCHANGE PLACE
LAKE MARY, FLORIDA 32746
MR. MIGUEL RODRIGUEZ
407-942-9358
CABLE:
11ME WARNER CABLE
3767 ALL AMERICAN BLVD.
ORLANDO, FLORIDA 32810
EDWARD MISlCKA
407-532-8526
TELEPHONE:
BELLSOUlH ORLANDO
500 N. ORANGE AVENUE
ORLANDO, FLORIDA 32809
MIKE BRYAN
407-245-3078
UNllED lELEPHONE-WlNlER PARK
352-343-8770
PREPARED FOR:
MIRANDA TOWING
ICS INDUSTRIAL-COMMERCIAL STRUCTURES, INC.
PREPARIED BY
!oIm H. We6I1 k Associllfes, lJfC.
CIVIL & ENVIRONMENTAL CONSUL TING ENGINEERS
925 S_ DENNING DR., WINTER PARK, FLORIDA
TEL_ (407) 822 - 9322 FAX. (407) 822 - 9325
E-MAIL, WEBBENGRoAOL_COM
IJV~
~OHN B. . Vf~I!..B, P.E. . 19951
DATE: 7/I/D3
~
"I;f
..J
..J
-
~
"I;f
~
OJ
.:)
J...
GRAPHIC SCALE
10
I
40
I
lID
I
20
I
( IN FEET )
1 inch = 20 It.
'"
f
CUU SCREEN WALL
SEE DETAIL ljC-6
0'"
CD CO
,CO
CD .
OCD
eyO
ey
OJ
..J
-
~
~
a
.s
o
0::
Q
~
--
<::
~
"I;f
It
J...
~
vi C)'
0(0
~)j
"-=-
'"
o
fv)
WET
DETENTION
POND
LJ..JLJ..J
'"
'"
'"
oCo
",0 ()
'-0'"
t--. 0)
~~
eyt--.
ey
C/) C/) J
~ CMU SCREEN WALL
SEE DETAIL 1 jC-6
SITE DATA
ZONING:
EXISTING LAND USE: T-C
PROPOSED LAND USE: T-C
SETBACKS c!c YARD REQUIREMENTS:
FRONT YARD
15 FT. MINIMUM
SIDE YARD
NO REQUIREMENT
(3' MIN. IF PROVIDED)
* ENGINEERING/SURVEYING L1C, II 3763/LB3763
NO. DATE
CUU SCREEN WALL
SEE DETAIL 1 jC-6
T-C
Vacant
FRONTAGE
ROAD SHALL
HAVE CROSS
ACCESS
EASEUENT
NORTH TO
SOUTH
-
6.X16. CONC,
VERTICAL CURB
(TYP.) SEE DETAIL
SjC-6
291.30'
,
266,89 !
TEUPORARY WALL FENCE
SEE DETAIL 6 jC- 7
S 51 01 5' 00"
S 51026'59"
(DEED)
(MEAS,)
w
w
24,00'
1
1
1
1
1
1
1
12'X12' DUU STER - --
1\1
I ..
~ONE WAY / - ASPHALT ~ t ~l , .~ S'R r
DO NOT ENTER ?8 PAVEMENT ~ /6 CONC, SIDEWALK
'\ lS'R SIGN ~ SEE DETAIL 9jC-6 ~ / SEE DETAIL 6jC-6
IT ~-r 70.00,1) ~
///// //// ///"8~~//)./// ///j/~ ~ R< ~
;j/jj/jjj/jj;/jj/jjj/jj/~/ s #\~"
{~/jj//j{:,;:;j~:';f{:,;::j{/jjj~ tt /
';}/jjfFUTURE BUILDI~G PADj///j;~~. /~ /
//j///;////p,.7~S;)//;//////j ~ 7 m_ /
~j/;;;/;;f;jj/;;fjj;f;;;~; ~ // ~
fj:,;::;{:,;:;;(:';;-~;::;/:,;:;;(:,;f;~ ~ . / ~
~ . . /' IV,VV co
LS'R ~/ '::'. 7 ~ H~AP SlGII "
~ ~ ~ KUd~~C~
::Jf}; V; I /! ,~,~
c ~~~ ff ::<~~.~~~
b
o
c:i
o
--
~ ~ 7\rC!SlGII
~~ ~~-S'I
~ "'. P' ::l :S'R
I ..:.." ~)
"\..... 1 0 'R
- <? ASPHALT
- PAVEMENT
= ~SEIE DETAIL 9jC-6
- '1/ rS'R S'R
'\
b
o
It'i
--
b
o
N
I'
II
0,
o
N
LO
c:i
LOV
I:!.V1~"~NC. ~
VERTICAL CURB
(TYP.) SEE DETAIL
0lC-6
o
<
o~
a::: <co
1.&.1 I- I
(!) 1.&.1 0
<0,
I- 1.&.1 N
ZI.&.I
oen
a:::
I.&...
(I)
1.&.1
o
<
0..
en
co
ENCLOSURE ~TH
WOODEN GA E
SEE DETAIL ljC-6
AND 13jC-E
~...' .:,. :;;l :.....:: '.'
. . .-
. . ~: ... .... .' -'
." . '., ..,.4..,..
..;,. .... :>-~~ . . .. - :~ ..:. ~ . .~: .~ ~.: ~ .
:~.~.<.: ~::': ~0':'~ .>.:.~. ~~:.:
.. ... . .. .. - .. ... .... -..
.__ .__. .... .. . .... 1.._,
6'R
20.00'
I
~
.in
co
ex)
(
24,00'
-
20,00'
6, 0'
37.67'
.
I
b
o
ex)
o
--
II
0,
1-1-
~z
<(1.&.1
~(3 '0
~> 0
-- < "^
-- 0.. ,- I
co
II
0,
~~~
1.&.1
o
<(
0..
en
I'
..;.-:
.....1..-
24 Po'
'. ':.-
ASPHALT
PAVEMENT
SEE DETAIL 9 jC-6
in
co
ex)
(
~
LS'R
b
o
~
N
b
o
N
,."
~
in
..J.
6'R
-
'0
o
~
N
6.X16. CONC.
VERTICAL CURB
(TYP,) SEE DETAIL
SjC-6
~I
-
""'"
N51030'23"E
N 51 015' OO"E
f
24,00'
(MEAS, )
(DEED)
I~~
Vacant
328.24'
351,10'
I
PARKING REQUIREMENTS:
AUTO SERVICE
BUILDING 1 (PHASE I)
BUILDING 2 (PHASE II)
TOTAL BUILDINGS 1 & 2
PARKING REQUIRED
BUILDING 1 (PHASE I)
BUILDING 2 (PHASE II)
TOTAL
1 SPArf../200 SF BUILDING
3,000 SF
3,784 SF
6,784 SF
SllE DATA:
PR~CT AREA
59,513 SF = 1.366 AC
BUILDING PHASE I
BUILDING PHASE II
PAVED
RElENTION POND
PUMP STATION
GREEN AREA
3,000 SF = 0.069 AC =
3,784 SF = 0.087 AC =
3S,811 SF = 0,822 AC =
13,911 SF = 0,319 AC =
400 SF = 0.009 AC =
2,607 SF = 0.060 AC =
5,04 X
6.36 X
60.17 X
23,37 X
0.67 X
4,39 X
15 SPArf..S (1 HANDICAPPED
19 SP Arf..S 1 HANDICAPPED
34 SPACES (2 HANDICAPPED)
PARKING PROVIDED
PHASE I (SlRAlGHT IN ON FRONTAGE ROAD)
STANDARD 36 SPACES
HANDICAPPED 2 SP Arf..S
PHASE II (ANGLED ON FRONTAGE ROAD)
STANDARD 34 SPArf..S
HANDICAPPED 2 SPACES
TOTAL AREA 59,513 SF = 1.366 AC = 100 "
TOTAL IMPERVIOUS AREA 42,595 SF = 0,978 AC = 71.57 X
TOTAL PERVIOUS AREA 16,918 SF = 0,388 AC = 28.43 X
DESIGNED IiFV
DRAWN ....
CHECK .BII
JOtot4 a WEBB. P.E.
BY APPR'D. PRO.ECT ENGINEER
REVISIONS
APPROVED FOR JOHN B. WEBB
& ASSOCI A TE5. INC.
IJVA/U-
i ~ FlORIDA 19951
101m H. w~" ~ lite..
CIVL & ENVIRONMENTAL CONSUL 7WG ENGINEERS
926 S. DENNING DRIVE. WINTER PARK, FLORIJA 32789
WINTER SPRINGS AUTO SERVICE CENTER
MIRANDA TOWING
ICS N:XJSTFIAL -coMMERCIAL S1RJCllIES, tc.
-
3=
..........
a:::
EXIST, CONC. DRIVE TO BE REMOVED
AND A EA RESTOR 0 IN ACCORDANCE ~TH
FOOT NO CITY OF ~NTER SPRINGS
REQUI MENTS. RE OVE CURB TRANSITION
AND 0 OP CURB. STRUCT FOOT
TYPE · · CURB TO MATCH EXISTING
CURB, NDEX 300. EUOVE CONCRETE
DRIVE. ONSTRUCT '~DE CONC. SIDEWALK
TO UA CH EXISTING SIDEWALK, INDEX 310.
/i
~V
--/
26,00'
EXIST.
CONe.
> DRI\E V- 24. SID. CURB
~ AND GUTTER
~ r- (TYP.) SEE DETAIL
V / 3/C-6
/
1/
1.&.1
Z
:J
a:::
~
::>
C>
\
/
zjr
\. ;'~~~~2S'R /r-
~~, '';Y
A~I ~ 6'Ib V
--
--~ 0
l'-.. ~
I"'-- N
-:. :: .~ . .' ..l' :.'
....... ..
:... . ... - ~
14,00'
26,00'
"
....
o
o
.
o
o
N
~ s' CONC. WALKWAY
/ SEE DETAIL 6jC-6
/
/
. .... ....
v
~
g..+
N ~
co
--
.
~
.
en
~~
~~
l~~
/ / =~
STOP ~GN --.I 1 "'-.
24. SID. CURB " ~ ADD CURB RA PS PER FOOT INDEX 304
AND GUTTER
(TYP,) SEE DETAIL ~ BOTH SIDES
3jC-6 ~C> ~:
FRONTAGE ~
_ ROAD SHALL
HAVE CROSS
ACCESS
EASEMENT
NORTH TO
SOUTH
."l ~ :
s
....
....
CD
~
....
n
~
o
OJ
n
EXIST, ASPHAL
AND AREA RES
~TH FOOT AND
REQUIREUENTS.
b
LO
"
--
2S'R
NOTES
3=
..........
a:::
TO BE RE OVED
IN ACCORD NCE
OF ~NTER RINGS
CON TRUCT 3' V LLEY GUTTER
ACR SS THE DRI IN ACCORDANCE
WITH INDEX 300. EE DETAIL 17 jC-6
1, PROPOSED DEVELOPMENT SHOWN MEETS CONDITIONS
OF BINDING DEVELOPMENT AGREEMENT NO. 2002902560,
RECORDED .l.JL Y 1, 2002,
100 YEAR FLOOD PLAIN:
2.
IN ACCORDANrf.. WITH .THE ENGINEERING SlUDY AND DRAINAGE
INVENTORY FOR L1T1l.E LAKE HOVtfil BASIN., PREPARED BY
GEE & GENSON, INC. FOR SEMINOLE COUNlY, FLORIDA, DA lED
MAY 2, 1997, THE lao-YEAR FLOOD ELEVATION IS 22.00 FEET.
LOCA lED APPROXlMA 1EL Y 700 FEET Yt{ST OF THE SllE,
3=
..........
a:::
3=
..........
a:::
GENERAL NOTES
1. FOR LEGAL DESCRIPTION, BOUNDARY INFO" AND BENCHMARK INFO.,
SEE SllE SURVEY SHEET C-8.
2,
PRIOR TO ANY CONSTRUC110N, CONTRACTOR SHALL FIELD STAKE ALL
CENlERLlNE GEOMETRY TO ENSURE PROPOSED DIMENSIONS FIT
EXISTING CONDITIONS. CONlRACTOR SHALL NOTIFY ENGINEER
IMMEDIAlELY IF ANY DISCREPANCIES ARISE.
3. CONlRACTOR IS RESPONSIBLE FOR PROlECTION OF ALL PROPERlY
CORNERS.
4, CONlRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRElE
AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT.
5. THE EARTHWORK FOR ALL BUILDING FOUNDATIONS AND SLABS SHALL
BE IN ACCORDANCE WITH ARCHllEClURAL BUILDING PLANS AND
SPECIFICATIONS,
6. CONlRACTOR SHALL REFER TO ARCHllEClURAL PLANS FOR AClUAL
BUILDING DIMENSIONS, COlUMN, RAMP & DO~SPOUT DRAIN LOCATIONS,
7, BUILDING DIMENSIONS SHO~ ON THE CIVIL ENGINEERING PLANS ARE FOR
REFERENCE PURPOSES ONLY. \\1-iEN LA YlNG OUT THE PROPOSED BUILDING
FOUNDATION, THE CONlRACTOR SHALL USE THE ARCHllEClURAL AND
STRUClURAL PLANS FOR EXACT BUILDING DIMENSIONS.
9. GENERAL CONlRACTOR IS TO COORDINATE WITH APPROPRIA lE UTILllY
COMPANIES PRIOR TO CONSTRUCTION, ADJUSTMENT OR RELOCATION OF
EXISTING UTILITIES AS DESIGN A lED ON PLANS.
10, CONlRACTOR SHALL REFER TO ARCHllEClURAL PLANS AND SPECS FOR
AClUAL LOCATION OF ALL U11L1lY ENlRANrf..S, TO INCLUDE; GAS,
SANITARY SEYt{R LA lERALS, DOMESTIC AND FIRE PROlECTION WA lER
SERVlrf.., ELEClRlCAL AND lELEPHONE SERVICE. CONlRACTOR SHALL
COORDINA lE INSTAlLATION OF UTILITIES IN SUCH A MANNER AS TO
A VOID CONFUCTS AND ASSURE PROPER DEPTHS ARE ACHIEVED, AS
Yt{LL AS, COORDINAlE WITH UTILllY COMPANIES FOR APPROVED
LOCATIONS AND SCHEDULING OF TIE-INS/CONNECTIONS TO THEIR
FACILITIES.
11. CONSlRUCTION SHALL COMPLY WITH ALL GOVERNING CODES AND BE
CONSlRUClED TO SAME.
12. CONlRACTOR IS RESPONSIBLE FOR REPAIRING THE DAMAGE DONE TO
ANY EXISTING IlEM DURING CONSlRUCTION, SUCH AS, BUT NOT
LIMITED TO, DRAINAGE, UTILITIES, PAVEMENT, SlRlPING, CURB,
ETC. REPAIRS SHALL BE EQUAL TO OR BETTER THAN EXISTING
CONDITIONS,
13, CONlRACTOR TO REMOVE OR RELOCA lE, WHEN APPLICABLE, ALL
EXISTING BUILDINGS, FOUNDATIONS, BASEMENTS, CONNECTING
IMPROVEMENTS, DRAIN PIPES, SANITARY SEYt{R PIPES, POYt{R POLES
AND GUY WIRES, WA lER MElERS AND WATER LINES, WELLS,
SIDEWALKS, SIGN POLES, UNDERGROUND GAS, SEPTIC TANKS, AND
ASPHALT, SHO~ AND NOT SHOWN, WITHIN CONSlRUCTION LIMITS AND
'M-iERE NEEDED, TO ALLOW FOR NEW CONSlRUCTION AS SHO\\t.J,
14. CONlRACTOR SHALL FOlLOW ALL LOCAL, STATE AND FEDERAL
REGULATIONS IN DISPOSING OF MA lERIALS REMOVED FROM THIS SllE.
15. ALL PAINT USED FOR PARKING SlRlPING SHALL BE LAlEX BASED
PAINT, 00 COATS OF PAINT TO BE USED.
16, DIMENSIONS SHOWN ARE TO FACE OF CURB UNLESS OTHERWISE NOlED.
17, SlGNAGE AND TRAFFIC MARKINGS SHALL BE IN ACCORDANCE WITH
F.D,O,T. AND CllY OF WlNlER SPRINGS REQUIREMENTS.
18. PLEASE NOlE, SOME EXISTING IlEMS TO BE REMOVED HAVE BEEN DELElED
FROM THIS PLAN FOR CLARllY, SEE SURVEY PLAN FOR IlEMS DELElED.
19. ALL DISlURBED AREAS WILL BE REGRADED TO MATCH EXISTING CONTOURS
AND SODDED WITH ARGENTINE BAHIA.
20. THE PROPERlY DEVELOPER AND CONlRACTOR SHALL COMPLY WITH USEPA,
NPDES AND C1lY OF WlNlER SPRINGS STORMWA lER MANAGEMENT &
REGULA 11ONS,
21. ALL ROOF MOUNlED EQUIPMENT WILL BE COMPLElEL Y SCREENED FROM VIEW
VIEW BY PARAPET WALLS OR OTHER ARCHllEClURALLY INlEGRAlED ROOF
SlRUClURES.
22. NO PERSON SHAlL UNDERTAKE LAND CLEARING OR THE REMOVAL OF ANY
PROlEClED lREE WITHOUT FIRST OBTAINING A PERMIT FROM THE BUILDING
DEPARTMENT. THE REMOVAL OF PROlEClED lREES SHAlL BE MINIMIZED TO
THE MAXIMUM EXlENT POSSIBLE AND NO AUTHORIZATION SHALL BE GRANlED
TO REMOVE A lREE IF THE DEVELOPER HAS FAILED TO TAKE REASONABLE
MEASURES TO PRESERVE SPECIMEN AND HISTORIC TREES.
23, PARKING IN FRONT OF BUILDING ALONG FRONTAGE ROAD SHALL BE
STRAIGHT IN (PHASE I)A T THE COMPLETION OF CONSTRUC11ON. AFTER
THE DEVELOPMENT OF ADJArf..NT PROPERTIES AND CONNECTION OF
FRONTAGE ROADS, THE PARKING IN FRONT OF THE BUILDING WILL REVERT
TO ANGLED PARKING (PHASE II).
24. CONTRACTOR TO INSTALL CONSlRUCTION ENlRANrf.. TO SllE OFF OF S.R, 434
CONSISTING OF A 50' X 50' X 6- LAYER OF FOOT #57 STONE TO MINIMIZE
TRACKING OF SEDIMENT TO ROADWAY.
25, CONlRACTOR SHALL FOlLOW THE REQUIREMENTS OF FOOT INDEX 623
FOR ANY LANE CLOSURE AND' INDEX 622 FOR SIGNS TO USE VttiEN NO
THRU LANE IS CLOSED, THE 4' PAVED SHOULDER MAY BE CONED OFF
TO ALLOW WORK ON CURB. CONlRACTOR SHAlL FOlLOW THE REQUIREMENTS
OF FOOT INDEX 660 FOR ANY SIDEWALK CLOSING. NO LANE CLOSURES
BETWEEN 7: 00 AM AND 8: 00 PM.
26. CONTRACTOR TO OBTAIN NDPES PERMITS,
27. CMU SCREEN WAlL SHALL BE 6 FEET ABOVE THE HIGHER SIDE OF THE
ADJArf..NT GRADE,
28. SEE SllE LIGHTING PLAN WITH DETAILS OF FlXlURES, HEIGHT, POlES AND
PHOTOMElRlC PLAN BY BUILDER.
29. BUILDER TO COORDINA lE IRRIGATION, LANDSCAPING AND LIGHTING PLANS
WITH THE SITE DEVELOPMENT PLANS.
DATE
JUNE, 2003
ENGR'S. PRo.ECT
107-Q1
SITE DEVELOPMENT PLAN
SCAlE
C-2
SHEET
OF7
'-20'
I
IJI
~
cri
~:>:'
I '-'-
.sa
i{~
,,~
f#
i2
iZ
co
~
-
~
Q:'
/-..
~
~
~
-
~
~
~
co
.:::>
/-..
I
I
I ,
I
I
r
I I
I I
I I
I
,
I
I I
I
I 9-.- --
I
I
I
I
I r
I
I
/ I
I I
I I
, /
/
I
I
I
I
I~
I~
'a
I~
Ii
I~
----
1<:
I 0::;
I IV)
I
I
I
I
/
I
I
. .
I
I
/)
J I
J ,
/ I
/ I
/ I
/ I
/ I
I
I
o
o
N
n
1
I
I
I
I
I
I
I
I
)
/
/
/
MANHOkf TR. 45.Q
-'
I
a
a
J)j
/
/
/
I
I WET
/ DETENl10N
J POND
I
I
I
I
I
I
. -
. .
8- PVC- SS PLUG
(FUTURE CONNEC110N)
INV. 40.71 NEW PRIVATE LIFT STA110N
SEE DETAILS SHT C-5
.. ENGINEERING/SURVEYING L1C, # 3763/LB3763
NO. DATE
REVISIONS
00000000
~~o~o~~~
r--.lXlcnO"-:Nn'<t-
nnn'<t-'<T-.:j--.:j--.:j-
I
. .
I
I
I
)
DESlGNED BPI
DRAWN ...
CHECK Ji!Ni
..at4 a WEE. P.E.
BY APPR'D. PROJECT ENGINEER
3:
...........
~
. .
- .
I
I
L_-l
I
I
I
BURIED 600 PAIR CABLE I
I I I I
~ IAr' BURIED 1200 PAIR CABL~
:Ii I II I
~ 1/1 I I
I /( I I I
V I I CD NOTE: NEW 4- 16t GAS MAI$NCENTL Y
I I I INSTALLE~ IN R/W BE EN SIDEWALK
I I I & R/W L1~E (LOCA 11 UNKNOWN),
I I I I I
I I I I I
I I I I I
I I I I I
I I I I I
l-lJ I I
I I I I I
I 111 I I
I~III ~ I I
':illl ~ I I
I~lll (V) I I
IV'll II ~ I I
lull\ ~ I I
I~ III . I I
w 1~()I~1 ~ I I
5 I ~ 1 f:, LL. I I
1~ll · I I
:Ii I~ I. I en I I
:iiI I I I I
". . I : I : VERIFY LOCATION: :
I I I I I
I : 1\ INSTALL 4- X 2- PVC TEE I
: I I I
I I INSTALL 6- X 4- Pf REDUCER:
I I I I
II INSTAll 6" lEE ANp FH WI APFuR.
I I
INSTALL 12- X 6- M:T TAP, RE$TR, JOINT
INSTALL 6- GATE ~LVE, MECH.I JOINT
I I
I I
I I
I 1
I I
I I
I I
I I
I L_,
I I
I I
I
I
1
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
II
"
II
II
II
II
"
I I
II
II
II
II
"
II
I ,
I I
I I
I I
i I
II
"
I
I
I
I
I
I
I
I
I
I
I
. .
. .
. .
- -
. .
. .
.
-- -
.
w
> .
a:::
Cl
~ l
> V'l
x
w
/
"- //.
v .
I
.
.
I
'I ~ 3- PVC, SLEEVE
II SCH, 40
~~-. ~~~
u
,.,....,. 7"-- .,.~- -~ .,....,.,.~".. ,-.!"- -~ "'.-7 :~/
I////;///;//;}~~/;///;//;;/.
(:////////// //////////.///// ///////
1-// . / . // . // . / . // . // . ..
IJ:~/;////~~~/~(~/~~/~/;//~ :,:..
~;';/;;;FYTUR;/BUIL~I~G P";,Dj'/;;;~:,:
.//;/// ;-/// ///;/// //// ///j
Vj'///j'///;//;///;///;//;/
r/;;j';;;ff;;/~~f;;;f;;f/j .
,. ~. .
/
/
/
/
/
-. .' - -.":,. '. . ~ -. :-. ";" :.- '~
~:~ :~:::;'~/-. /.: ...:. ~.:.:: ~'.:." ._(~..
.): .:~~. .:~.;L .~.,~.: .:.:< '...}....:~; ::.
CLEANOUT 11 ~
INV. 44.50
SEE DETAIL 14/C-6 ~
/-
/
/
65LF-SS 6- PVC
o 1.08"
I
I I
II
I I
V'l
V'l
CLEANOUT 12 ~
INV, 43.80
EE DETAIL 14/C-6
I
/ ~
/'
W 1- P
/ W 1- P
W 4- P\tC
/'
/'
/
24LF -SS 6- PVC
<<>> 1.05%
CLEANOUT 3 INV 43,15
SEE DETAIL 14/C-6\
3" PII'C, SLEE~ t
SCH, 40
I
I
I
I
II
II
II
II
II
II
I !
"
II
II
II
I !
II
I i
11
II
1 I
II
I i
II
II
I i
I
I
i
)
...--/
II
3- PVC, SLEEVE ~II
SCH. 40 II
I
423 LF - 2.5- PVC F\4
3- PVC, SLEEVE~II
SCH. 40 II
I
2,5- PVC, FORCE MAIN
II
. .
. .
. .
. -
. .
- .
PROVIDE FIRE LANE STRIPliNG
Sanitary System Construction
1, The 2.5" PVC force main will remain a private line and will not be turned over to the City of
Winter Springs. The 2,5- PVC force main will be plugged and abandoned in place after
connection to future gravity sanitary sewer,
2. Wastewater service shall be provided by City, The wastewater distribution system shown on these
plans shall be installed by Contractor and shall conform with the City's standards,
3. Sanitary Sewer shall be PVC SOl 35 conforming to ASTM 0-3034 or DIP PC 350 (DIP shall be
polyethylene - lined,) conforming to ASTM C151, Installation of PVC pipe shall be in accordance with
ASTM 0-2321, DIP joints shall conform the ANSI/AWWA C11 0/A21.1 O.
4. Sanitary Sewer force main pipe shall be PVC conforming to AWWA C900 and shall have a
dimension ratio of 25, Sanitary Sewer force main joints shall conform to ASTM 0-3139,
5. All force main piping shall be restrained in accordance with restraint tables shown on the plans,
All fitting shall be mechanically joint restrained. No thrust blocks or thrust collars shall be permitted,
6. Compact all utility trenches within the roadway to 98" of the Modified Proctor Maximum Density
and 95% within other areas,
7. Install valve boxes with all valves, Valve boxes under the driveways shall have traffic bearing
covers, No valves shall be located in pavement or curb areas.
8. Contractor shall provide force main pressure testing and sanitary sewer lamping/television in
accordance with City requirements prior to certification, Tapes must be in color and clearly show the
service lateral tie-ins as well as the pipe connection points, The test pressure for sanitary sewer
force mains shall be 150 psi.
9, Contractor shall provide certified As-Built drawings prepared by a Florida licensed Professional
Surveyor and Mapper providing information relative to sanitary sewer invert/rim elevations, line and
service locations. As-Built Drawings shall verify accuracy of all pipe slopes, Minimum slope for
service lines is 1'" Two sets of As-Built information shall be provided to the Engineer a minimum of
1-week prior to scheduled Final Inspection of work.
EXIST, FH
TO BIE REMOVED
AND IRELOCA TED
SEE FORCE MAIN CONSTRUCTION
DRAWINGS FOR INSTALLATION OF
FORCE MAIN IN FOOT R/W
HEET C-3A & C-3B
--- 6- FM
SEE FORCE MAIN
CONSTRUCTION DRAWINGS
FOR CONNECTION TO
E)((ISTlNG CITY FORCE MAIN
!oIm H. WdJ6 Ie, A8s0dtdes, /...
CIVIL a ENVIRONMENTAL CONSIA. TING ENGINEERS
925 S, DENNING DRIVE, WINTER PARK, FLORIDA 32789
WINTER SPRINGS AUTO SERVICE CENTER
MIRANDA TOWING
ICS tIXJSllIAL -couUERCIAL S1RJC1\JRES, te.
. FLORIDA 19951
3:
...........
~
3:
...........
e::
GRAPHIC SCALE
~
10
I
20
I
40
I
1IO
I
( IN FEET )
1 inch = 20 It.
UTILITY NOTES
1. CONTRACTOR IS TO VERIFY LOCATION OF ALL U IG UTILITIES PRIOR TO START
OF CONSTRUCl1ON,
2. SANITARY SE\\rR, FORCE MAINS, AND STORM SE\\rRS MUST CROSS UNDER
WAlER MAINS WHENEVER POSSIBLE. SANITARY SE\\rRS, FORCE MAINS AND
STORM SE\\rRS CROSSING WA lER MAINS SHALL BE LAID TO PROVIDE A
MINIMUM VERTICAL DISTANCE OF 18 INCHES BEMEN THE INVERT OF THE
UPPER PIPE AND THE CROWN OF THE LO\\rR PIPE WHENEVER POSSIBLE,
WHEN SANITARY SE\\f:RS, FORCE MAINS AND STORM SE\\f:RS MUST CROSS
A WA lER MAIN WITH LESS THAN 18 INCHES VERTICAL DISTANCE, BOTH THE
SE\\f:R AND THE WA lER MAIN SHALL BE CONSTRUClED OF DUCTILE IRON PIPE
(DIP) AT THE CROSSING. (DIP IS NOT REQUIRED FOR STORM SEWERS.)
SUrnOENT LENGTHS OF DIP MUST BE USED TO PROVIDE A MINIMUM
SEPARATION OF 10 FEET BEMEN ANY TWO POINTS. ALL JOINTS ON THE
WAlER MAIN WITHIN 20 FEET OF THE CROSSING MUST BE MECHANICALLY
RESTRAINED, A MINIMUM VERTICAL CLEARANCE OF 6 INCHES MUST BE
MAINTAINED AT ALL CROSSINGS.
ALL CROSSING SHALL BE ARRANGED SO THAT THE SEWER PIPE JOINTS AND
THE WA lER MAIN PIPE JOINTS ARE EQUIDISTANT FROM THE POINT OF
CROSSING (PIPES CENlERED AT CROSSING),
WI-IERE A NEW PIPE CONruCTS WITH AN EXISTING PIPE WITH LESS THAN 18
INCHES VERTICAL CLEARANCE, THE NEW PIPE SHALL BE CONSTRUClED OF DIP
(EXCEPT STORM SEYf:RS) AND THE NEW PIPE SHALL BE ARRANGED TO MEET THE
CROSSING REQUIREMENTS ABOVE,
A MINIMUM 10 FOOT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN
ANY TYPE OF SE\\rR AND WAlER MAIN IN PARALLEL INSTALLATIONS WI-IENEVER
POSSIBLE.
IN CASES WI-IERE IT IS NOT POSSIBLE TO MAINTAIN A 10 FOOT HORIZONTAL
SEPARATION, THE WAlER MAIN MUST BE LAID IN A SEPERAlE TRENCH OR ON
AN UNDISTURBED EARTH SHELF LOCA lED ON ONE SIDE OF THE SEVt{R OR
FORCE MAIN AT SUCH AN ELEVATION THAT THE BOTTOM OF THE WAlER MAIN
IS AT lEAST 18 INCHES ABOVE THE TOP OF THE SEMR
WI-IERE IT IS NOT POSSIBLE TO MAINTAIN A VERTICAL DISTANCE OF 18
INCHES IN A PARALLEL INSTALLATIONS, THE WAlER MAIN SHALL BE
CONSTRUClED OF DIP AND THE SE\\f:R OR THE FORCE MAIN SHALL BE
CONSTRUClED OF DIP (EXCEPT STORM SE\\rRS) WITH A MINIMUM VERTICAL
DISTANCE OF 6 INCHES. THE WAlER SHOULD ALWAYS BE ABOVE THE SE\\f:R,
JOINTS ON THE WAlER MAIN SHALL BE LOCAlED AS FAR APART AS POSSIBLE
FROM THE JOINTS ON THE SED OR FORCE MAIN (SUGGESlED JOINTS).
3, ALL WA lER MAINS SHALL HAVE A MINIMUM OF 36- COVER.
4. BACK FLOW PREVENTION DEVICES SHALL COMPL Y WITH aTY OF WlNlER SPRINGS
UTlLll1ES REQUIREMENTS.
5, ALL WA lER MAIN MA lERIALS AND APPURlENANCES SHALL CONFORM TO AND SHALL
BE INSTALLED, lESlED AND CLEARED FOR SERVICE IN ACCORDANCE WITH THE
aTY OF WlNlER SPRINGS UTILITIES REQUIREMENTS AND THE REQUIREMENTS OF THE
FLORIDA DEPARTMENT OF ENVIRONMENTAL PROlECTlON,
6, THE CONTRACTOR SHALL PERFORM HYDROSTATIC lESTlNG OF ALL NEWI.. Y-INSTALLED
WA lER DISTRIBUTION SYSlEMS IN ACCORDANCE WITH THE aTY OF WlNlER SPRINGS
UTILITIES REQUIREMENTS AND IN ACCORDANCE WITH A WWA STANDARD C600 FOR
DUCTILE-IRON PIPE, AND AWWA MANUAL M23 FOR PVC PIPE,
7, THE CONTRACTOR SHALL DISINFECT ALL SECTIONS OF THE WAlER DISTRIBUTION
SYSlEM IN ACCORDANCE WITH THE FDEP WAlER PERMIT, AND RECEIVE APPROVAL
THEREOF FROM THE LOCAL WAlER Ul1LlTY, ENGINEER OF RECORD, AND FDEP, PRIOR TO
PLAONG IN SERVICE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN COPIES OF
THE FDEP WA lER AND SEWER PERMITS FROM THE OWNER AND MAINTAIN THEM ON THE
JOB SllE AT ALL l1MES, DISINFECTION OF THE WA lER DISTRIBUTION SYSlEM SHAlL BE
PERFORMED IN ACCORDANCE WITH AWWA 651 -DISINFECTING WAlER MAINS AND THE
STANDARDS OF CITY OF WlNlER SPRINGS UTlLll1ES.-
8. PLASTIC WA lER SERVICE PIPING AND FITTINGS 1 THROUGH 2 INCHES SHALL CONFORM
TO THE REQUIREMENTS OF AWWA C800 AND eg01 (POLYETHYLENE TUBING). PVC
SERVICE PIPING (2) INCHES THROUGH (3) INCHES MAY BE SDR 21.
9. UNDERGROUND FIRE LINES SHALL MEET NFPA 24 REQUIREMENTS.
10, THE LOCA l10NS OF ALL EXISl1NG UTILITIES AND STORM DRAINAGE SHOWN ON THE
PLANS HAVE BEEN DElERMINED FROM AVAILABLE INFORMATION AND ARE GIVEN FOR
THE CONVENIENCE OF THE CONTRACTOR. THE OWNER OR ENGINEER ASSUMES NO
RESPONSIBILITY FOR INACCURACY, PRIOR TO THE START OF CONSTRUCl1ON, IT SHALL
BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITIES AND TO
MAKE THE NECESSARY ARRANGEMENTS FOR ANY RELOCATION OF THESE UTILITIES WITH
THE UTILITY COMPANY, THE CONTRACTOR SHALL EXEROSE CAUl10N MiEN CROSSING
ANY UNDERGROUND Ul1LlTY. EXISTING UTILITIES WI-IICH INlERFERE WITH THE
PROPOSED CONSTRUCTION SHALL BE RELOCA lED AS DIREClED ON THE PLANS.
11. ALL WA lER AND SE\\f:R LINES ARE TO BE CAPPED lEMPORARIL Y AT THEIR OPEN ENDS
UNTIL CONNECl1ONS ARE CONSTRUClED,
12. WI-IEN TRENCH EXCAVAl10N EXCEEDS (5) FEET IN DEPTH:
A. CONTRACTOR SHALL CONFORM TO OSHA SID, 29CFR, SECTION 1926.650.
B, THE CONTRACTOR SHALL PROVIDE YtRITlEN ASSURANCE OF COMPLIANCE WITH
THIS LAW.
C, TRENCH SAFETY SYSlEM SHALL BE BY THE CONTRACTOR.
13. CONTRACTOR SHALL COORDINAlE PLACEMENT OF TRANSFORMER WITH PO\\{R COMPANY,
14, PROVIDE FIRE lANE STRIPING AND SIGN AT EACH FIRE HYDRANT IN ACCORDANCE
WITH CITY OF WlNlER SPRINGS REQUIREMENTS.
15. THE FIRE LINE MA lERIAL TO CONSIST OF egOO CLASS 200 DR14 PIPE.
16. SOIL BEDDING AND BACKFILL FOR UTILITY PIPE AND STRUCTURE INST ALLA 11 ON
SHALL BE COMPAClED TO A DENSITY OF NOT LESS THAN 98" (PAVED AREAS)
OR 95" (UNPAVED AREAS) OF THE MAXIMUM DENSITY AS DElERMINED BY
AASHTO T -180.
DATE
JUNE, 2003
ENGR'S, PRO.ECT
107-01
SITE UTILITY PLAN
SCALE
C-3
SHEET
OF7
1--20'
c/) (;'{-~- c)[- 1--:' VIV! r.
~
-
-.J
)...
I-
es
""""Q.
()--
~~
U)I-
U)U)
~L:5
a2:
a::::>
+0
aU)
,-.
t5
~
U)~
10 00
~
.....
0)
~
<.t)
CONTRACTOR TO VERIFY CLEARANCE
FOR FITTINGS FROM BACK OF CURB
PRIOR TO D/RECnONAL BORE
6" PVC EXTEND TO R/W (VERIFY W/
CITY UnL. DEPT.)
I I
--------
---.---
------------
..----.---
6" CONC. ENCASEMENT (NOT THRUST BLOCK)
"
I't)
.....
C\j
......
6" PLUG VAL VE, R.J.
I I
G R j:.S S M [ D ! A f\J
6" X 2-1/2" PVC TEE
2-1/2" I,D. HOPE FORCE MAIN
,
i
.--tt
letl
b !
Ii);):
...."
I '
. I
iC~1
~
,~_I
1(/"):
~!
~,
I .~.
12'
---
2-1/2" x 90. PVC BEND
2-1/2" 1.0. HOPE FORCE MAIN
XTEND DOWN TO CONNECT
TO 2-1/2" PVC BEND*
SOL VEN T WELDED CAP
6" 1.0. HOPE CASING PIPE~
6" 1.0. HOPE CASING PIPE
2-1/2" 1.0. PVC FORCE MAIN
MAINTAIN 6.5' DEPTH TO
EDGE OF R/W
EXTEND UP TO CONNECT
TO 6" X 2-1/2" PVC TEE*
2-1/2" PVC/HDPE ADAPTOR
i i
; I
I J
9+00
I I
,
S.R.434/419
~ FORCE MAIN PLAN
+
1- -
--+-
- -I
--1
.-t
f- -
...,
t-m
+CW)
01
....U
. .
Co
I-Z
01-
lUlU
ZIII
-Z
~CI)
UIII
I-IU
C0
:E
N. T.S.
I I
I i
HAND EXCA VA TE PIPE TRENCH IN
AREA CROSSING BENEA TH EXIST.
PIPE. MAINTAIN MIN. 6.5' DEPTH TO
EDGE OF R/W MAINTAIN 18' MIN.
CLEARANCE BENE A TH WA TER MAIN
START HORIZONTAL DIRECTIONAL DRILLING
(SEE FORCE MAIN DETAILS THIS SHEET)
6" 1.0, HOPE CASING PIPE
\<<,v<<<
It) if~"-if~"-if
co
.....
0)
~~~
'~..w<<
~'v~., .,'\.,.
TOP OF GROUND
--
"
""'>
.....
C\j
......
, I TOP='46 10
j ! FLOWUNE=45. 76
'E, //1/\1.,3872
_ :.~ ~_'~. ~._',~.~~' A ~-~~t.l:v-_~:...:-~.~....__ =~~'_'-:~~.~-~~'. .~~.~~-=_-~ -- _:~~~_C:iTR!/-&.jUT!.if~? -~ c'--
, .=-:. .=-:. .:-:. .:.-.:. __ -/F~ .~ =4 >Or:; .,>;... _ _ -T-:';... - . -- =-- =-- . -.. -=..' - =-=--= .-;:
v \ . ..;;. IV' . "1 ....,. \7 . , .
; L._' I .ct",. r' "'1\ '," '1IilL' "J '.
" . ./', t '-. ,) , " '. . I V 1..<rJ V " t\
_ ~ ~ __'- . _,_._ ---.-:.-:., _.?_. '___ _ _~ . --'-- .~.-L....- _._._.:........... . ___~ _ ____ '" .JL_u__ _......:..
~--- L >'is T ' ') "r)ip lA' '1
, L..~\,. I~_L,., H'.I\..
~
CI)
PVC/HDPE ADAPTOR (TYP.)
6" I,D. PVC FORCE MAIN
~ WA TER MAIN
---~-----
...~ '.~'~ ~~_o\ .__~_' ~--=.. _~ .~ .~. i-~~~ _'.-!
- -~.=-~ -~~~ ---~.~~. .,;,. ..~ . .. '- ~ .~.: ;, ~< ~. :~, ~.~.~. .~. . :~~. ~. '~. ~.
18" MIN. VERT. CLEARANCE
EDGE OF PIPE TO EDGE OF PIPE
'i7 ,,'. '.' . . . <::I'.' .' .'. ,"J. 'i7
-4GM---~--.--~-~----~-~------
. 2-1y2"I.m' HDPE r.M, '. .
--,-",SL:... _ __ ___ -- - -
----l:1 _ _ ~ --'-_
CAP~
---.._-
--- --
---- -
2-1/2" 1.0. HOPE FORCE MAIN
6" CONC, ENCASEMENT 6" 1.0. HOPE CASING PIPE
(NOT THRUST BLOCK)
~ FORCE MAIN PROFILE
PVC/HDPE ADAPTOR (TYP.)
--
--
-.-.--. GHW --.- . --.
FDO~R. FND ~EXIST
-TEL ,RISER
--. -= OHW=-- - -1?/W . ~\
. - ----..
TEL EPHOWE "- [
6" MIN. CONC. ENCASEMENT
(NOT THRUST BLOCK)
-------
-
----------
---
R/W
OH W .~----
'-EXIST. BUP/ED
-- --
N 38.43'16" W 200.00'
Oh W -.-.
T{:'I
I.:......l....
--
N. T.S.
PROPERTY LINE
,-.
- ..
EXIST. <:
12UW.U."" ;
6.5' .0
R/W
.1
I 46
I
i 44
42
6" COMM.
SLEEVE
. 5" nAY
'-' .f\
I
I
fXIST. ASPHAL 1
J DRIVE (TO BE ~
REMOVED) II..(
I
;-- - - ___-1 C)
:s
Q.
c::i
FOOT I.R. FND
FENCE ENDS ON LINE
15'
..
WINTER SPRINGS AUTO
SERVICE CENTER
-.:
IkI
I~
-.J
}..
....
~
&.5' OAK
It
2' CURB &J
GU TTER
~. ~
~5' GONG. SIDEWALK
j:.. ._:_ :: .:. ,". '.~ ,t ~ TOP ~::""~D
'v":.. "-if). "-if
,
,
~
15'
EXIST.
4 "GAS MAIN~
2.5'
... ..
3.5'
I
~
NOTES:
1. HORIZONTAL AND VERTICAL LOCATIONS OF EXISTING UTILITIES SHOWN BASED ON NON-DESTRUCTIVE
EXCA VA TION PERFORMED BY GROUNDHOUND DETECTION SERVICES, INC., MAY, 2003.
2. ROAD STATIONING DEPICTED IS ASSUMED. SOUTHEAST PROPERTY LINE IS ASSUMED STATION 10+00.
~
~.....'"-
,..d..l_ '"
e:~~
U)
I
I
t 6" OAK
2-1/2" I,D.
HOPE FORCE
MAIN
6" 1.0. HOPE CASING PIPE
t
CROSS SECTION AT STA. 10+50
SCALE: 1 "=4'
_____~___l_L___LU_:_l_L___:L_i ____________ ______L_~___:_~__L___:_~_ L___:_~_~L_:L_:L___ L__~__L_L_~_:L_:_:_ _~L_lLLLL_LL_ L_L_L_:_ _lL_lL_~_l_U_LL_l_:_LL_l_U_ _l__~_UmlLL___L__] __~L____:j_~L_LIL L:L____L:L_U_:L _U_L_____~LL:___U_L ----- ~L___:_;__L_~_:_ :___l_L_l_l____lL___:_l____ _l__ ~_U__. _L ________m _:____L_l_-_ l_____m___ -- :_U___U_Ll_________
~ . . . . . .. ~...... ~ . . - . . .. ......... - . . . .. ................ ................ ................. ....... ......... ............... .......,.......... .................... ................. ......... ~ . .. . .. . .. ............... -..Oo.................. ................ - . .. ............... - ........
. . . . .. .. .. " .. .. . . . .. ..
. . . . . . .. j . . . . . . .
......t. - -
: : : : : : :: 1 : : : : : : :
~-. -
.. .. .. . .. . . ~ . . . .. . . .
. . .. . .. .. . . . .. . .. . . ..
. . . . . . . i . . . . . . .
.. . . . .. . . . . .. .. . .. .. ........ ~ . . . . . ... ............,.......... ............
; : : : : : :: ::::::::::::::: ::::::::::::::: :: I't) ::::::::::: :::. 'Exis:T.: BURltD: 6 0: &: 1200 PAiR: CABLE: ::::::: ::::::: ::::::: ~ : : : : : :: ::::::::::::::: ::::::::::::::: :~. : : : : : :: ::::::: i : : : : : :: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: :::::::: 44
44 ..: :.:~_:: :: ............... ............... . . . . .. .'~.-.. ... .'. .... 'AND'COMMUNICA lON-DUCT' . . . .. . .. ....... ....... .__~~.P~.~__.:....:.._:..~..___._~_ ....... I '.:~. .'._" _:..u.~___"""'" '.~_..___ ~~_...:....~:.___h:.~ ._........:_... . ~.---:.. . . "--"' . .. . . '-' . .".... .. ............... ............... .......:......... ........
~ . . . .. . .. .................... ................... . .. .. . . .. ......... ...................... .......... + .. .. . . . .. ........................
42 e[
-:.: -. 7~_-Z::~~-~'u. - :~:::-r.~eWAltJ:-:~:__- Z7 -;:Z-~^K:" ::__: '-:: _-:_: 7A7=:- :W~:::::: ::: : ::::;:::: -::-: ::::::::::::
:....... ...i_~~~... .. .....~~:~~:~..:~~::EST.:12"DIP.WATERMAIN ..,:~~..:~.. ...... ~:~. ....... ..... . ......... ..... .....~:.:~.... .Zlll....... ............... .......j....... ............... ............... ............... ........
<: ~ . . . . . .. ....... ....... . . . . . .,. I. . . . . .. ....... ........ . . . . . . . j . . . . . .. ............... ............... ............... ........
: : : : : : :: ::::::::::::::: ::::::::::::::: : Q:.~' ~~ ~; : : : : : : : . . . . . ., ............. .. :CJ illl: : : : : :: ::::::: j : : : : : :: :::::::;::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::
............ .........t......... ....................... r----~"""' ~
: : : : : : :: ::::::::::::::: ::::::::::::::: :"'C. -J a: i:::jt:t' . . . .. ............... ::::::"&:::::: ............... ....... t . . . . . .. ................ ............... : : : : : : : : : : :: .......:....... ............... ............... ............... ............... ........
---------~-~-:-~-~-:-~-~- ~-~-:-~-~-:-~-~-:-~-~-:-~-~-:- -~-:-~-~-:-~-~-:-~-~-:-~-~-:-~- I...l~~~.:~_:--++- ++-----H-u-----:- ++-+~-:,+-+-.-:- --~-h-+H-:-H-:-+: ~-~-:-:-~-H+-++~-:- -h-~-:-H+-H-h-~-h-~- :+-:-+H-:+-H- :-:-_ ~-~-:-~-r, -:-~-~~-~-~-:- -:-+:-:-~-:-H-:-:-~+-~- -H-:-:~-:-~+---h-~-:- ~-h-~-:-H-H-:-~-H-:-- -H-~-~-:-~-:-H-h-~-:---:- -:-:-:-H-:-:~-:-:-~-h---:- ----::---H-~---------
: : : : : : :: ::::::::::::::: ::::::::::::::: ~. ~ .Q:; it;;J;: . . . . .. ............... ....... t . . . . . .. ............... ....... i . . . . . .. ::::::::.::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: :::::::: 36
36 ........ ............... ................. a", ~a::"'. . .~.' .. ............... ............... ....... 1 . . . . . . . .."..:..~..: . ...:...:............ .......__._... ..- .....-----...--. '-'-' ....---.--.......--...--..-......----.... .....--..-........-....... - ... . ---......
-.. .. :'::-':' : H_:- :.': -:-:": : : : :-H:: : : : : :: ::::::::::::::: +~: ~ ~ ~:~r : : : :: ::::::::::::::: :::::::;::::::: ::::::::::::::: ::::::::::::::: :::::::::::::::: ::::::: i : : : : : :: :::::::;::::::: :::::::;::::::: :::::::;::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::
: : : : : : :: :::::::;::::::: ::::::::::::::: ~ ~:~)..J ~:~: : : : :: :::::::;::::::: ::::::::::::::: ::::::::::::::: :::::::;::::::: ::::::::;::::::: :::::::;::::::: :::::::!::::::: :::::::;::::::: :::::::;::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::
---------~------------- ------------~------------ -------------------------- -~~~~~.~-:~-~-:~-~ ~-~-:~-~-:~-;-:~-~-:~-~-: -~-:~-~-:~-~-;~-~-:~-~-:~- -:~-~-:~-~-:1-~-:~-~-:~-~- ~-~-:~-~-:~-T-:~-~-:~-~-: -~-:~-~-:~-~-;~-~-:~-~-:~- ~-~-~-:~-~-:~-~-:~-~-:~-~- ~-~-:~-~-:~-T-:~-~-:~-~-: -~-:~-~-:~-~-t~-~-:~-~-:~- -:~-~-:~-~-:~-~-:~-~-:~-~- ~-~-:~-~-:~-~-:~-~-:~-~-: -~-:~-~-:~-~-~~-~-:~-~-:~- -:~-~-:~-~-:~-~-:~-~-:~-~- ~-~-:~-~-:~-~---------
t .. ~ .. . .. .. ........... t . .. .. . .. ... ........................... '""l-J ""-l... ""'-J -, '-I;J . . .. . . . . r .. . . . .. ..... ....................... ..................... .......................... .. . .. . . . .. . .. . . . .. .... .......................... ........................... .................. .......................... ...................... ..............
i : : : : : :: ::::::: i : : : : : :: ::::::::::::::: : ~:'?:~ ~:~: : : : :: ::::::::::::::: ::::::::::::::: ::: .:.. :..:.: .~:_:..:: : :..:__:..:_:_.: :_.:..:. : : .:. : :._: ..:.:. : : : : : : ::..L.:.:..~__:_.:.__:~.,~__: :_: ~:,~:,:, ::..:.:._:...:..:..:. : .:..: :..:.~.:.: :_:...:.: :::::::!::::::: ::::::::::::::: :::: :..: : : : :: : : : :1 :: : :.: : :: : : : :.::: .::::::::::::::: ::::::::
10+50
----.....,.--
.. .. .. . . . .. .. ... .. . .. . .... .................... ... . . . . .. . t .. . ... ... . .. ........... ~ . . . . . . .
~-~-.-~- ~-.- ~ -~-.-~-~-.-~-~-.- -~-.-~-~-.-~-~-.-~-~-.-~-~-.-~- -.-~-~-.-~-~-.- -~-.-~-~-.-~-~- ~-~-.- ~-~-.-~-r-.-~-~-.-~-~-.- -~-.--:-~-.-~-:-T~-~-.-~-~-.--:- -.-~-~-." ~-.-~-~-.-~-~-.-~-~
-----t------
-----~----
----~~----
~ . ... . . ..-
-----~----
__...4.a_
-----,....-----
. . .. . .. . . ~ . . . . .. ... .
......-
9+00
9+50
10+00
* ENGINEERING/SURVEYING L1C. # 3763/LB3763
7/8/03 EXTEND HDD/FM 35' WEST PER CITY
DEE
JBW
DESIGNED F!IFV
DRAWN ~
CHECK JIll
~ B. WEBB, P.E.
PROJECT ENGINEER
APPROVED FOR JOHN B. WEBB
at ASSOCIATES, INC.
IJ VAAA-
fl. H. We6I1 k Assodafes, 1JIC. *
ClVL & ENWlONMENTAL CONSUL 7WG EJtIGMEERS
926 S. DEIHN8 DRIVE. WNTER PARK, FLORDA S2789
WINTER SPRINGS AUTO SERVICE CENTER
MIRANDA TOWING
ICS INDUSTRIAL -cow.4ERCIAL S1RJCnJRES, INC.
OFFSITE FORCE MAIN
PLAN AND PROFILE (1 OF 2)
DATE
JUNE, 2003
ENGR'S. PROJECT
107-01
NO.
DATE
REVISIONS
BY
APPR'D.
SCALE
1--10' HORIZ.
1--4' VERT.
~;~T C-3A
TOP=46.97
F:. IN V. = 38. 67
II
I i I
I
I
I
~I
EXIST. CONC. DRIVEWA Y TO BE REMOVED
~ I AND AREA RESTORED IN ACCORDANCE WITH
~ FDO T AND CI TY OF WIN TER SPRINGS
~ REQUIREMENTS
1......
ii-I _
I
I
I
-+--
I I
I ,
II
II
II
~II
.\ I
ct:
~II
~II
12~q
~II
II
II
II
;' ..~. .' '<- - ~~-.-.:: L':' ~~ ~C~ :.:-.:~. ---::.~ "-_ ~ J_ .:i-.~ .~- . -~ 2~CURB ~&~J;V!TtR..' -' -; :-'-:-- ::-=-~:1-.:.. - ~ '-.~ :.....-- ~". ~.~.'., '''''--~'. ~ · .c::'<:' ,'..; -~ i; .
(j
~ I'
lu 1
~
.-...C
+M
O.
...u
. .
Co
I-Z
01-
ILl ILl
ZILI
-:c
it/)
UILI
I-ILI
ccn
::E
11+00
--1
-~
1
I
1
1
1
1
1
1
I
~I
~I
V)I
C:1
J
I
~I
5:;,
lu
1
1
1
1
1
I
I
I
f-- i I
:s
a
< ! I
C) I'
U ,I
lu
Q. ! I
~ ;!
1-
--+--
-I
.
\0
~ III
V) I
~
~
! I
I ,
1-
1- -
S.R.434/419
6" 1.0. HDPE CASING PIPE
END HORIZONTAL DIRECTIONAL DRILUNG
(SEE FORCE MAIN DETAILS SHEET C-3A)
-~k .'.
" .
- -,- -5:-CONC.-WA~J.<: -:- -.1.G.~~-.
.__. -- -.,.-. _._.---~ --- '---'- ;,;,...~..,.~- ---
~ -~ ~ ~ -. - ~- ~ ~~ ~ _.- -~ -..-'" .-- .--
.... .' ".. .....~2'...CUR8&-GtjTTER.!... ......... ..... ..' .'.
. _ ~"'. _' ---..,-. ----7-- ---=-- "- -" - _6 - .~. -- ..t... - ~ -L. --- -- ~ Jz..... ......... --~-
. ':J /'
. <:) . <J <q L - ~ - - -- __ ~ __ __ _..
. . . ~ . 'Q ;"<;J . . . \;7.' .' . . ~'." . . . \;7' EX~S1T1NG DR1v. :4 Y ...' .' , " ~ t' .
- - ~ - _..:3 - - - - - _ _ _ ~_ _ _ _ _ _ _ _ _ _ :l.'_ _ '..L <:). IV' . . u .' .' .lI l' '. 5 C;ONC. WALK
_~: 7L?"/~D, J1DP~.!M. __ _., v ~. '__. _~_ __ _ ___4 ~~~.__...~~ ___ ~_-:- =, ~-~_=- --=. -_~_ --=. -_~_ ~_-=- :..=4 ~f' - - - ~_:~\;'~"T ~ -_=~- -l---=- _'V-.::-v - -. - -=- - ;.- ~ -!c.M. IV' ~_-= -= :.-=--= ~--= -_~ ~-=.
- - - - - - - ~ 'f -=I><J-;;:--~ - - - - - -~ -
- - - - - - - - - - - - - -_ - \~ - -_ _ _ _ _.' _ - -=- -~ _.-::.. . - --, ~ EXI
. ~ _ -:- -- -- .-=-. _-~ . ....=-. ~7'WJHW - _' _ - '_~' - . ----;;;- .I2HW -- '_~' - --;;;. '_- . - . _ . F?/W' - . .;;;-...; - ---;;;;; (JtIw -..--- . _-~ _.,- . '-_
,!...P -[] GA! ,/ I I I
- EXiST. 12"OIP W.M. EXIST. 6"F.~I~-TUBi~ - ----~~EX~T. 6" HOPE :EC CONDUIT
, GI+W
-
-------,----
---.---=-- -T=' ---- OHW --~ - --::....--
--~ -- --
"-
"'-- FX'CT TE.-' r:Pf.JON'-
, I.~.. . L~ 1 t:.
1ST. 12"DIP WM.
NOTES :
1. HORIZONTAL AND VERTICAL LOCATIONS OF EXISTING UTILITIES SHOWN BASED ON NON-DESTRUCTIVE
EXCAVATION PERFORMED BY GROUNDHOUND DETECTION SERVICES, INC., MAY, 2003.
2. ROAD STATIONING DEPICTED IS ASSUMED. SOUTHEAST PROPERTY LINE IS ASSUMED STATION 10+00.
: : : : : : :: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::: ::::::: ::::::::::::::: ::::: ::r::n:-:u: :::: :_:_:~ : : : : : : u:':_: :_::::: : : : : :: ::'::: _:: :::: : :: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::
---------~-~-H-~-H-~- -+:-~-H-~-~-:-+:-~-H- ----:-H-~-~-~:m-- - ~ -+ --~-- -~~----+H----- --- :---~--:-~-~-H-H-----:- -.--.+-:+:-~-- -.-~-::--.- u~_~:_:_.-_.-. ---H-H+- ++~-:-~-h-:-H---H- -~-H-~-:-~-+-+-~-H- -+~-:-~ ~r:~ l-~-:- ~-:-~~-~-:-~-f-+H-~-H- -~-H-~---:-:-:-:-~-:-:-:-:-:- -:-~---:-~-~:-~-:-+H-+ : - :-:-~-::---: --: --.--- H- -.--'-- -H---- -~~-~-H-- -:-~- -H-::-: -:-H-: -:- --::- ~-:- --: u:-:-:--f-- ------
; ::H- ...:..:.... -::.::::.:::.::.::., - ....:: -..:..:....: : - . : : - : : : . . . . - . - ~ . . - .: :.::' >H::o: >.:t~~!.~-~: :::::-~<::.::: ::. :::<. . : : :. ':':::':::::": ..::.:.. :...:.::." - .: .':"':"'!:'.
--4---64---6----
_.:.:->.:::: ::~~~: :~~:~~:~:~::.:::~ ::~~~:::: :::::~:~~: :~~__!:~::::"'<::.:c:~~ ::~~j:_::_:':':n ::u::~~~~:~~ ::<:::_::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: :::.::::::::::: ::::::::
. . . . . . . . . . . . 4 . . . . . -. ::::::::::::::: ::::::::: ::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: . J I ~ t::: '-' --- Yi : : : : : : : : : : : : : :: ::::::: ~ : : : : : :: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::
: · · · · : . - . . : : : . : : . . . . . . . ~ : ~ ~ ~ ~ : i ~ ~ ~ ~ ~ : ~ __u_m:uj(m__.-u _:____u~ ~ ;fi~m n-:mu:uT-----:um:- m:-n---nTn-:mum u_mum-:-___m_m_ un-n--_n-unn---- --_uu-----.-n-u---:m -mn:m_-n-( >ni1-: -:-_nmt-~m
. . . . . . . ; .- . . . . .. ....... ...;-:-..:. . . . .. .... V) l&d ~ U.U c.. ..... :.. .-'.---.- j . -. . . : .. ........ ,---,-'. -. ''- .. ............... ............... ............... ............... ........
-----......---- -----1- --- --- ----- -----................... ............................. ..............".............. ...... _ .. .. .. .. .. .. .. .. .. .... .............................. .... _ .. .. .. .. . .. .. .. .. .. .... .............
-----~---- ------t-. --- --- ~---- -----+--...... ............... ............... ............... ............... ............... ........
42
.. .. .. .. .. .. .. .l. .. .. .. .. .. .. ..
: : : : : : : j : : : : : : :
. . . . . . . . . . . . . .. .......!....... ............... ............... ............... ............... ........
40
! .. .. .. .. ..
~ .. .. .. .. ..
i . . . . . .
.. .. .. .. t .. .. .. .. .. .. ..
,
.. .. .. .. .. .. .. . .. .. .. .. .. .. ..
.. .. .. .. .. .. - t
40
,
. .. .. .. .. ..
l .. .. .. .. .. .. ..
. .-t-.
.. ~ .. .. .. .. .. .. ..
j . . . . .
'.A ' ....... ....... ...... ....... .......
---------~-:-~:-:-~.. ~~ ~-~~-~-t~-~-~-:~-~-: -~~-~-~~-~-~-~~-~-:~-~-:~- -:~-~-:~-~~-;-~-:~-~~-~-~ ------------~---------- ------- ----~------------ ------------4-----------
; : : : : : . . . . . . . . . · . . . . . .. ............... ::::::::::::::. ::::::: ~-:- !/~': (.p, fipp( fQ~qE. :M.A.liy: . . . . . . . . . . . . . .. ............... ............... ............... ........
38 !:::::.' ill :::::::::::: ::::::::::::::: ::::::::::::::: :::::::;::::::: .......,....... ....... t . . . . . . . : : : : : : : 1 : : : : : :: :: .:.....:.._.:...:.,.:.._:.,..:._:...:__:,.:,...: _:..... : : : : : :: ::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: :::::::: 38
..-.." .....+-.....---....-..-. III' --,.".. ,-. ........... ----. .+..-... - .. .- ~_._,- . . .": :'-:'.r'---: '.' .-...... ..... :'..-.- .'..'- .-. .-' - "-"--'~
: : : : : : tn__:_ LL_LU_U___U_ _LU_LUL..._LLU_LU_ _~_LU_LLU,~L~_LU_LL LLU_L~_LLU_L~LL~_ _L~_LLU_LtLLU_LU_ _:.'-l.-~. _~._l._~. _~.-j.:,-~. _:.'_l._~. _~._~.'-~.' _ L~_:_~__ . . . . . . . . . . . . . .. :::::::;::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::: ~ : : : : : :: ::::::::::::::: ::::::::::::::: ::::::::
_n________nn____ . . . . ~ . . . . . .. ............... ............... ............... ............... . . . . . . . , . . . . . . .- -~-:-~-~-:-~-~t~-~-;-~-~-;-~- -;-~-~-;-~-~-;-i-~-;-~-~-;-~-~- ~-~-:-~-~-:-~-t-:-~-~-:-~-~-:- -~-:-~-~-:-~-~-~~-~-:-~-~-:-~- -:-~-~-:-~-~-:-1-~-:-~-~-:-~-~- ~-~-:-~-~-:-~-~-:-~-~-:-~-~-:- -~-:-~-~-:-~-~-:~-~-:-~-~-:-~- -:-~-~-:-~-~-:-~-~-:-~-~-:-~-~- ~_~-:-~-.~_:-~-~-nn---_
. . . . . . . . . . .. ............... ............... ............... ....... t . . . . . .. :::::::!::::::: ....... 1 . . . . . .. ....... I . . . . . . . ' . . . . . . . · . . . . . .. ............... ............... ............... ....... j . . . . . .. ............... ........
:::::::::::: ::::::::::::::: ::::::: :.::::::: ::::::::::::::: ::::::: j::::::: .......!....... ::::::::::::::: ::::::: t....... ::::::: 1::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: ::::::::::::::: :::::::: 36
............... .... .-..-.-.-. . ""-"'1,"'-:-. ..-:-..-:-.-:......-~. ........ ....... :.'-t'j'.-.......-...-........ ., .. .
. .. .. .. .. .. .. . .. .. .. .. . .. .. .. .. .. .... .............. r .. .. .. .. .. .... ...... - .. .. .. 1 .. .. .. .. .. .... ............................. .. .. .. .. .. .. .. , .. .. .. .. .. .... ::::::: 1 : : : : : :: ............. .. .. .. .. .. .... .............. ............................. ............................. ............................. .............................. ............................. .............
'I .. .. .. .. .. .. .. .. .. .. .. . .. .. .. .. .. .... .............................. ............................. .............. <I .. .. .. .. .. .... .............. t .. .. .. .. .. .... ............................. .. .. .. .. .. .... . I" .. .. .. .. .... .............. ............. t .. .. .. .. .. .... .............. t .. .. .. .. .. .... ............................. ............................. ............................. ...............
. .. .. .. .. .. .... .............. + .. .. .. .. .. .... ............................. .............. ~ .. .. .. .. .. .... ............................. ............................. .....::::: '.' : : : : : :: ::::::::::::::: .............. t, : : : : : :: ::::::: 1, : : : : : :: .............. .............. .............................. ............................. ............................. .............................. ............................. ................
. .. .. .. .. .. .... .............. ~ .. .. .. .. .. .... ............................. .............. ~ .. .. .. .. .. .... .............. ~ .. .. .. .. .. .... .......................... - .. .. .. .. .. .. . .. .. .. .. .. .. .... .............. ............................. ............................. ............................. .............,............. ............................. ...............
12+00 12+50
.. .. . . .. .. .. . .. .. .. .. .. .. ..
36
t .. .. .. .. .. .. ..
t .. .. .. .. .. .. ..
11+00
11+50
* ENGINEERING/SURVEYING Lie. # 3763/LB3763
DESIGNED f!/PI
DRAWN ~
CHECK SNi
f. H. We6/J It. As8lkill/es, lH1. *
ava. .. ENV6IOtMENTAL CONSLI.. TWB ENBNEER8
1126 S. /JEIIHN(J DRIVE, WNTER PARK, FLORIDA 327811
WINTER SPRINGS AUTO SERVICE CENTER
MIRANDA TOWING
ICS INDUS1RAL -coMMERCIAL SlRJCTURES, INC.
OFFSITE FORCE MAIN
PLAN AND PROFILE (2 OF 2)
DATE
JUNE,2003
ENGR'S. PROJECT
107-01
NO. DATE
REVISIONS
.JOIot4 B. wam. P.E.
BY APPR'D. PROJECT ENGINEER
SCALE
1w-1O' HORIZ.
1w-4' VERT.
:E;T C-38
1 MllERED END SECllON 1\
1 SEE DETAIL 7/C-6 I
FOOT INDEX 272
I INV, EL = 40,00 \
.. ..
I ~ I 10' MAlNTE~CE BERM \
. \ ~
1 j
'J 4 UAK... \ ~"
./ ...~U)
I .~ 0 A "
/;~~ -="81 ;1 ) ~~ 6" ...
I I '\ I '- - 0 ~~.
· I I I 1 I I 1 B' )AK
A " 42./0' '; I ~ -'39-_ /
~~ ~ _I
lCi5! () I ~
'/~~~' I
. I I I
~ / / I / :
- 800 I I
OA ~'~~ 8 I
/'OJ ,." N I
· I 7, '( g
. I I I .N
A 4:11 / I '? ffi
I I 2: 1 I - 6 " 0 ~ ~: 1 ~ I I 4: 1 :
1 1 0" OAK I <t '.' 0
1 _. I I~ ~ / - 6" 0 A ~ : \ : ~
. II 14J1 :; I I 0 0 0 0 0 0 0 0 ~
A 1 I CSt co I WET I ~ ~ ~ ~ 3 ~ ~ ~ ~
6 " 0 A K _ 1 I QI I DETENTION I t") t") t") ~ ~ ~ ~ ~
I 1 1 I POND I I I I b
- I 1 ) III --
r A"'\ a7 .' I,' EE IlETAll15jC-6 / - J-: !
~ .r.:t,'~/-1f - -// ./ ) I · -
OAK A' I'i+----JI / /,//,.../--)
I I 1 \__/ / /,/ /-
I I ( / / /,/
I ( \ / / /
· ( \ -------- / /
· ---------- /
Ar~ \ -- - -e-4~ -D-A-K - - - --
It e" nl~lr
v I'lL
. /
.1 /
/ .c::." (1^L( /
.
I 10' MAINTENANCE BER"/,
~% h, " (1 1'1 L(
.. ..
6" 0 K- - 6 " ~ K
0')
..J
.....
"If
Q:'
J.....
"If
..J
..J
.....
~
"If
~
0')
.:::>
/-...
I
1
1
I 6"
1
1
I
1
1
I
1
1
/ I
1
/
,';;;
I!J
10
IQ:
Ij
1 :)16"
1 ...
I~
. . .
--'^?
~ ~ ( ~ l---- .--/
~LJr~
~
X-X-X-'lO ---J'v- 1 11 "
l 1
1 l 44.80 EP
! .v. .v. 1/
/
18 LF 18- RCP 0 0.56';;
/
\
I
4 ,8 T~
r
./
./
./
..
. .
PROVIDE SIL FENCE ALONG
PROPERrt INE. AS A MINIMUM
EROSIO SEDIMENT CONTROL.
ADDI NAL MEASURES WHERE
REQUIRED. SEE DETAIL 18/C-6
SOIL EROSION CONTROL NOTES
USE VA VE
TOP=4 .05
FLOWLI E= 45.14
N. INV.-34.74
S. INV. 34.76
W. INV.=37.82
3:
" pp
ll< I/~
I a I I
I I I I
:E I I
I I
I I
NEW ST(ORM INLET NO, 4 I I
FOOT INllET TYPE 5 I
TOP E : = 4J,10 I: I
INV. DEir~L~ 6/C-6 I I I
I II
I I
.~ I / I
"tI 60 TC }' r- NEW STORM INLET N . 3
. . . A4i~,10 EP \ _ . . X' I FOOT INLET TYPE 5
41,50 '''"7 Y'~" 9 46.1 0 C / // I I :: ~ .to. 7~.15
~.oo E~ ,~- 46. 0 :p. - ~ _ - - I I SEE DETAIL 16/C-
_ 46.65 li . I I
/45?1\ t'D v w 168 LF 18- RCP 0 0,30" /46.15 E . I I
". .~. \ "'" r 34 lr4. 1Q- I I
:.;: .l tQ Y rr- PROVIDE SILT
'Wrf~-7""~'''''-A''''''-7,7.:-r.''''~ ;:",' 46115 TC ~ RCP Cl O,29~ " ~ /1 II RIGHT-OF
I ~ ~//~/ ///'8~~/~~Y'/~ jKj~;pj ~ 1 ~95ffi . ~ J > V _ L: EROSIONj
~ L" )(W ~. '/;//7~/f :71 ~/7~/ ;../?uj)..0 r? P f / . ~- I I ADDI110NA
~ OA'~ ~~. ~t >;i//~/'.. ~.' !//~0./ ~" ~ '- //. I I REQUIRED.
.r 1~~//~/(7(/~Y~~//~~~ !(~~~~ Q0 f' \I~~ V \ I
~~..//// .FUTUREBUILDINGPA (~. '..-:~. "47::~ I · I I
r;///j;;////////////////~//;;///\"; /A6. /~ l' I I
. . . .., I I
45.62 TC / L I I
45,12 EP "\ //~/: . J' /'// /',/177:/ //////~t?'.'S(Yr-'YJ ~./ / ~ I I
--v'v- ~ !/'L:~L~ /.W~.~/ /.'a~':L~/d'/~}ZT! ~ .~<~. ,/ // I · pp I I
/44.50 EP 45 70 ~C I \n47,~5:fC ~ ~~ LL-L '; .>:. /' ~ $E DETAil ~/C-6 ) \ I I
. I. - 1 STORY WOO / / ..... - .. - · - T/ · \.,
_.-:..:..:.:,....~.,]. ;:n::-t 45.20E~ 0 FRAME 'LJ47.~~~ - 21 ~-/./ {{ I i
:;.:.:'... .:.,.,"t!1:.65....r..:::,. ~~" n ^V N r:: -,d 0 U ~ .....~ ~,40 TC ~.)~
~':~:.~~..;_ '~::. :.:::;';. ....:.. '-J' ~"', FIN. FL.=4J. vW 00::: <0 .' -: , "'~jPI I I
,... ....,..: ;?\::. _,.....<~: . 0 TC ~ 0 ..- "It 1 1/ .5) I I
,(...~~ .:"'~;'" ~".\;', '.<.;..';.;. ~c::. A' CL ,,~(r /\ 46'~ EP '\. ..... '." '. I
'"ii:!aT TI' . .. ."",. -. . .... .
~5OEP I
I I I 18" R
45,62 TC d . / ItfjW 11== == .
I 45,12 EP I~
!~ ~EP 5.8JTC 47.9 m~1tl' l~'~/:~ I e OA" . : :~~:B4~~
. 13" / 5.33 EP ~ ~ ~~/'II~ .'~,::: l\l....v,~ / ~ . I II FLOWLINE
I OAK W JI'~ ',' /' """ / L& I
I _ ~'~~ ~6" (}R~':~ -: I IE. INV.=3
I ." n" r\ ^ 1/ ---J'v- a../L,~. '.JIll ~NVLl ~ I/-I NEW Sli
. I v v r ~d '\ t O/l .:. ; /-' , /' V I I FOOT IN
: 13" OAK 0:: iff / I: v~ 11f:J~~:L41
i .; '. ~: J ,/ 46,7) TC ~ II 'I ~ SEE DET
',~. ~.':. / ~ / ~.2 ~ EP I -'
...... ---"y ') 0-< I Ie..')
+ / r'" I ~ I
.:~~} \. ~, '\ "\ ~~1- II I I~
/': .:\ ~~ ~'TIy):-"" ,.,t.-*,. ~?", t J I gl
/ /~ ~ t.. Y/ 'Q X~6 TC~ . . ~ =~J 3
//~ 'L "'~:05 ~ 46.1 EP \ ~ ~ _ '.~r N
46.# /:-V\r- 'TU,DU IG - ~7,bo TC~~ ,
45.94 ~ ~ 46,10 EP I 46.50 EP Df VE I
\-- _~_ ..., f-~ I
~ _ _L---1;- '" ~"
46~ Il .... j 4O,t)U TC ...... c::~ ~,....l47 10 TC I
~5'9~ F'~:s.:: 46.10 EP I" 46 76 TC !:< t-~..:,. EP I
A" "^ 1/ 11" r\ ^ 1/ ... , ... d' ( AR. O~ I:'D '\ _. I
VI" .......
~ ~ I
~~
I~ \
1-
.-- STORM MANHOLE
FOOT INDEX 200
TOP EL = 44.50
INV, = 40.10
SEE DETAIL 9/C-7
. .
..
. .
. .
. .
"45,20 TC
44,70 EP
/
45.75 TC / .
/
~
~ (j)
Q)
~
Q)
---J'v-
----
/-5" OAK
45.62 TC
45.12 Ei~
-
rs,
~-V
-
M
~
z
.
^/
~
5.78 TC _
45.62 TC 45.2IrEP \. t
45.12 EP V
~" n^1/ ~
45.83 TC ^
OAK _ --;Lf- OAK 45,33 EP V"
---J'v-
47.20 EP
~
1
Q)
<p
~
46,15 TC / ---J'v-
45.65 EP
-e.lg" OAK
-7'~OAK
1~" n^1/
~
. .
. .
. .
. .
_ J
. --
1 0" OAK 5' OA~
. .
..
I I
NEW STORM INLET NO, 1 I I
FOOT INLET TYPE 5 -- I I
TOP EL = 46,10 I I
INV, = 41.35 1 I
SEE DETAIL 16/C-6 1 I
I I
I I I
I I I
1, ALL EROSION AND SEDIMENT CONTROL WORK SHALL CONFORM TO STANDARDS OF
CITY OF WINTER SPRINGS , FLORIDA AND THE S1. JOHNS RI\lt:R WATER MANAGEMENT DISTRICT.
2. EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO. OR AS THE
FIRST SlEP IN. CONSTRUCTION, SEDIMENT CONTROL PRACllCES WILL BE APPUED AS A
PERIMElER DEFENSE AGAINST ANY TRANSPORTAllON OF SILT OFF THE SITE.
3. SUCH MA lERIAlS, FROM WORK ON THIS PR~CT SHAlL BE CONTAINED, AND NOT
ALLOWED TO COLLECT ON ANY OFF-PERIMElER AREAS OR IN WAlERWAYS, THESE
INCLUDE BOTH NATURAl AND MAN-MADE OPEN DITCHES. STREAMS. STORM DRAINS.
lAKES AND PONDS.
4, DAILY INSPECTIONS SHAll BE MADE BY THE CONTRACTOR TO DElERMINE THE
EFFECTIVENESS OF THESE EFFORTS. ANY NECESSARY REMEDIES SHAll BE PERFORMED
WITHOUT DELAY.
.. ENGINEERING/SURVEYING L1C, II 3763/LB3763
NO, DATE
REVISIONS
~ 3: 19.
"
~ ~
20.
a
I
~ 21.
5. ALL MUD. DIRT OR OTHER MATERiAlS TRACKED OR SPIUED ONTO EXISTING
STATE-COUNTY-C1TY OR PRIVATE ROADS AND FAClUllES FROM THIS SllE, DUE TO
CONSTRUCTION SHAlL BE PROMPTlY REMO\lt:D BY THE CONTRACTOR/BUILDER,
6, PERMANENT SOIL EROSION CONTROL MEASURES FOR All SLOPES. aiANNELS. DITaiES
OR ANY DISTURBED LAND AREAS SHALL BE COMPlETED WITHIN (15) FIFTEEN CALENDAJi
DAYS AFTER FINAl GRADING, YfiEN IT IS NOT POSSIBLE TO PERMANENTlY PROlECT A.
DISTURBED AREA IMMEDIATELY AFTER GRADING OPERATIONS. TEMPORARY EROSION
CONTROL MEASURES SHAll BE INSTALlED, All TEMPORARY PROTECTION SHALL BE
MAINTAINED UNTIL PERMANENT MEASURES ARE IN PLACE AND ESTABLISHED. A
CERllF1CA TE OF COMPUANCE Will NOT BE ISSUED UNllL THE ABO\{ REQUIREMENTS
HA \It: BEEN MET.
7. EROSION CONTROL PLANS ARE TO BE SUBMITTED TO THE ENGINEER FOR ACCEPTANCE
PRIOR TO THE PRECONSTRUCllON CONFERENCE.
DESIGNED BPI
DRA'" Il...
CHECK JIll
JOtfi a wall. P.E.
BY APPR'D, PRo.ECT ENGINEER
'oIot 1J. We/J6 It Assoti4IeI, lJlt. *
O/VI. a ENVIROINENTAL CONSU TM ENBMEERS
926 S. /JENNI'/G DRIVE, WINTER PARK, FLORDA 82789
WINTER SPRINGS AUTO SERVICE CENTER
MIRANDA TOWING
ICS tDJSTFIAL -ca.u:RCIAl.. STRJC1UES, te.
. FLORIDA 19951
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
1
I
I
I
I
I
I
I
I
I
I
I I I
I
I II
I
I II
I
I II .
I CL
I \ I~
I 0:::
i II~
~
(j)
--
--
I
I \
I
I II
I
I II
0:::1
WI I \
I-
1-1
01 I I
~I
ml I I
0:::1
:::JI
u1
NI
I
I
I
I
I
I
I
I
I
1
I
I
1
I
I
I
I
I
I
I
I
3:
"
~
I
I
CURB
~
~
~
GRAPHIC SCALE
20 0
~
10
\
20 40
I I
( IN FEET )
1 inch = 20 ft.
eo
I
GRADING and DRAINAGE NOTES
1. UNLESS OTHERWISE NOlED. GRADE TO MEET EXISllNG ELEVA l10NS AT
PROPERTY UNES, CONTRACTOR SHAll PROV1DE POSlll\1t: DRAINAGE OF THE
SITE TO THE RElENllON POND AS SHOWN BY PROPOSED GRADES AND FLOW
ARROWS,
2. DURING CONSTRUCllON. THE CONTRACTOR SHAlL PROV1DE ADEQUA lE
DRAINAGE AND PROPER SOIL EROSION CONTROL MEASURES FOR
PROlECllON OF All DRAINAGE AND SEWER STRUCTURES. AND AT All
ADJACENT LANDS AND ROADS.
3. ALL PIPE NOTED ON THE PLANS AS R.C.P, SHALL BE REINFORCED CONCRETE
PIPE CLASS III WITH RUBBER GASKET JOINTS,
4. All SIDEWALK WIDTHS SHAll BE 6' OR AS NOlED AND SHALL HA\It: 1- DEEP
CONTRACllON JOINTS EVERY 4' O.C. MIN. SIDEWALK SLOPE SHAll BE 0,5"
AND A MAX OF 8.0"-
5. THE CONTRACTOR SHALL USE CONCRElE WITH A MIN. 28 DAY STRENGTH OF
3,000 P.S.I, FOR SIDEWALK CONSTRUCllON,
6. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ANY AND ALL
GEOTECHNICAL REPORTS PREPARED FOR THE 51lE, ALL SITE GRADING AND
SIDE DRAIN INSTAlLAllON IS TO CONFORM TO THE GEOlEaiNICAl
REPORT/SPECS AND DETAILS. EXACT SIDE DRAIN lOCAllONS ARE TO BE
FIELD DElERMINED BASED ON SIDE DRAIN DETAILS AND NOT BY SCAUNG
FROM THIS PLAN,
7. PROV1DE SILT FENCE TYPE III AlONG THE PROPERTY LINES DURING CONSTRUCllON.
8, THERE ARE NO CONSERVAllON!WETLAND AREAS WITHIN THE PROPOSED
PRO~CT SITE,
9. ELEVAllONS SHOWN HEREON ARE BASED ON THE SUR\lt:Y PREPARED BY
JOHN B, WEBB c!c ASSOCI AlES. INC.. LAND SUR\lt:Y1NG DIV1S1ON DRAWING
~O. 107-01 DAlEO 7-25-2002,
INLE I
10, EXCAVATION, PAV1NG AND STORM SEWER WORK SHALL BE DONE IN
ACCORDANCE WITH F,D.O,T. -STANDARD SPEClFlCAllON FOR ROAD AND
BRIDGE CONSTRUCllON- AND CITY OF WlNlER SPRINGS SPEClFlCA l1ONS.
11. SOIL BORINGS AND SOIL ENGINEERING SERVICES HA \It: BEEN PROV1DED BY THE
PROFESSIONAl GEOlEaiNICAl ENGINEERING FIRM EMPLOYED BY OWNER.
ADDI110NAl SERVICES WILL BE PROVIDED TO THE CONTRACTOR UPON REQUEST
BY THE OWNER. THIS ENGINEERING FIRM ASSUMES NO RESPONSlBIUTY FOR THE
CORREClNESS. ACCURACY. AND COMPLElENESS OF THEIR WORK. EXCAVAllON OF
UNSUITABLE FILL AND COMPACllON SHALL BE DONE IN ACCORDANCE WITH THE
SOILS REPORT PREPARED BY THE PROFESSIONAl GEOTECHNICAL ENGINEERING FIRM.
12, THE SllE SHAll BE CLEARED OF All TREES EXCEPT THOSE Wl-ilai ARE
DESIGNATED TO BE SA \It:D OR RELOCATED. BEFORE CONSTRUCllON. THE
CONTRACTOR SHAll MEET AT THE SITE WITH THE ENGINEER AND/OR
OWNER. AT THIS TIME, ANY TREES TO BE SA \I{[) SHAll BE POINlED OUT AND
TAGGED, THESE TREES SHAll BE PROlEClED FROM DAMAGE.
13, THE CONTRACTOR SHALL lOCAlE All UllUllES OR UNDERGROUND
STRUCTURES PRIOR TO CONSTRUCllON AND NOllFY EACH RESPECll\1t:
UllUTY OWNER A MINIMUM OF FORTY-EIGHT HOURS (TWO WORKING DAYS)
PRIOR TO COMMENCEMENT OF CONSTRUC1l0N.
14, THE CONTRACTOR SHAll RESTORE OFF-SllE CONSTRUCllON AREAS TO AN
EQUAL OR BETTER CONDI11ON THAN EXISTED PRIOR TO COMMENCEMENT OF
CONSTRUCllON,
15. THE CONTRACTOR SHAll IMMEDIA lEl Y NOllFY THE SUPERVISING
ENGINEER IF A PA\lt:MENT OR FOUNDAllON STAKE IS DISTURBED.
16. THE CONTRACTOR SHAll CONSTRUCT PA\lt:MENT IN ACCORDANCE WITH
TYPICAL PA\lt:MENT SECllONS AND F,D.O.T. STANDARD SPECIFlCAllONS
FOR ROAD AND BRIDGE CONSTRUCllON. AND CITY OF WINTER SPRINGS
REQUIREMENTS. THE FINISHED PA\lt:MENT GRADES SHAll CONFORM
TO THOSE SPECIFIED ON THE GRADING PLAN,
17, THE CONTRACTOR SHAll CONSTRUCT ALL STORM SEWER
APPURTENANCES IN ACCORDANCE WITH F.D.O.T, STANDARD
SPEClFlCAllONS FOR ROAD AND BRIDGE CONSTRUCllON. CURRENT EDlllON.
18. PRIOR TO COMMENCEt.4ENT OF CONSTRUCllON. THE CONTRACTOR SHALL
MEET WITH. AND SUBMIT A CONSTRUCllON SaiEDULE TO. THE ENGINEER
AND SECURE All NECESSARY UCENSES AND PERMITS.
EROSION CONTROL PLAN WILL BE SUBMITTED TO AND APPRO\lt:D BY THE
ENGINEER PRIOR TO THE PRE -CONSTRUCllON CONFERENCE,
DRI\lt:WAY ENTRANCE AT S.R. 434 RIGHT-QF-WAY. SHAlL BE CONSTRUCTED
TO F.D,O, T, REQUIREMENTS.
All CONCRElE PIPE JOINTS SHAll BE WRAPPED WITH TYPE 0-3 FILlER
FABRIC AND SECURED IN ACCORDANCE WITH FOOT INDEXES 199 AND 280
(PAGE 1 OF 4),
22, SOIL BEDDING AND BACKFILL FOR STORM DRAINAGE PIPE AND STRUCTURE
INSTAlLATION SHAll BE COMPACTED TO A DENSITY OF NOT LESS THAN 98"
(PA\lt:D AREAS) OR 95" (UNPA\lt:D AREAS) OF THE MAXIMUM DENSITY AS
DElERMINED BY AASHTO T -180,
DATE
JUN:, 2003
ENGR'S. PRO.ECT
107-01
GRADING and DRAINAGE PLAN
SCALE
C-4
SHEET
OF7
'-20'
CUSTOM PUMP & CONTROLS, INC,
PACKAGED FIBERGLASS PUMP LIFT STATIONS
PACKAGED FIBERGLASS VALVE BOXES
D,E.P, OR STANDARD CONTROL PANELS
JAX. (800) 940-3758 TAMPA (800) 940-3309
FURNISH AND INSTALL A COMPLETE PRE-PACKAGE CUSTOM PUMP & CONTROL
GRINDER PUMP STATION AS DESCRIBED BELOW
SPECIFICA TIONS
DESIGN CONDITIONS
MODEL
WGL 20-01
H.P.
PHASE
2
VOLT
208
DISCHARGE 2.5"
IMPELLER 5"
GPM
TDH
53
35
E!J.Me
1HE PUMP SHALL HA ~ AN INlEGRALL Y BUILT" GRINllER UNIT AND SUIIMERSIIll.E TYPE lIOTOR. lHE PUMP
SHALL BE SUSPENDED .. 1HE IIASIN BY TWO (2) l' GUIDE RAILS AND QUlQ( DISCONNECT I.FT OUT lolOUN1ING
ASSDB. Y. SOIJOS SHALL BE FtD IN AN UPfLOW lllREC110N TO 1HE GRINDER IoIECHANISN WllH NO
08S1RUC1KlNS BELOW 'THE ClRlNDER IHLET.
lHE GRtIOER UNIT SHALL BE C""~ OF CUTllNG SOUD WAlERIAL rOUND IN NORWAL DOWESTIC SEWAGE.
INQ.UIllNG 1lEASON~ AWOUNTS OF rORElClN OBJEClS, SUCH AS WOOD PI..AS1lC, GLASS. RUBBER.
SANITARY NAPOlS. lllSPOSA8lE DIAPERS AND PANTY HOSE INTO A FINE SLURRY 'IllAT WILL. PASS FREELY
lHROUGH 'IllE PUMP, SEIMCE UNE AND rORCE WAIN.
MQIQB.
lHE PUUP lIOTOR SHALL BE OF 1HE SUBWERSllllE TYPE RAlED rOR 2 HORSEPOWER AT 34SO RPW. WOTOR
SHALL BE SINGLE PHASE. 20lI IIOLT, 80 HERTZ. SINCll..E PHASE lIOTORS SHALL BE OF 'IllE CAPACITOR START-
CAPACITOR RUN TYPE rOR HIGH STAR1lNG TORQUE.
1HE STATOR WINlllNG SHALL BE 'THE OPEN TYPE WI'Ill Q..ASS A INSULAllON RAlED rOR 105' C WAlCMM
OPERAllNG TEWPERAlURE. 1ltE WlNDINO HOUSING WILL BE FUED WI'Ill a.EAN DIELECTRIC 01. 'IllAT WILL.
LU8RICA lE BEARtlGS. SEALS AND TRANSfER HEAT f'ROW 'THE lllNOlHGS TO 1HE OUlER SHEU.. lHE lIOTOR
STATOR IS TO BE PRESSED INTO lHE lIOTOR HOUSING rOR OPlllolUol CONCENTRlOTY AND AUGNWENT. AND
WAXllilUW HEAT TRANSFER. 1ltE lIOTOR SHALL BE CAP~ OF OPERAllNG O~ FUll. RANGE OF
PERf'ORWANCE CURIIE WI1HOUT O\IERI.OAlllNG lIOTOR AND CAUSING ANY OBJECllONAI. NOISE OR
W1RAllON.
1HE lIOTOR SHALL HAIlE TWO lIEARINGS TO SUPPORT 'THE ROTOR; AN UPPER BALL BEARtIG TO
ACCOWlIODAlE 1HIlUST LOADS AND A LOWER BAU. lIEARING TO TAKE RADIAL LOADS. BALL BEARINGS SHALL
BE DESIGNED f'OR A La-l0 Ln (~OOO HOURS).
A HEAT SENSOR lHERWOSTAT AND OIIERlOAO SHALL BE ATTACHED TO 'IllE TOP END OF 'THE lIOTOR
WINDINGS AND SHALL STOP 1ltE lIOTOR F 1ltE WOTOR WINlllNG lEWPERAlURE REACHES 200' r. 1ltE HIGH
lDolPERAlURE SHUTOF!' WILL CAUSE 1ltE PUliIP TO CEASE OPERAllON, SHOULD A CONTROl. rAl.1lRE CAUSE
1HE PIM' TO RUN .. A DRY WET YIELL THE 1HERMOST AT SHALL RESET AUTOWA 1lCAI.L Y WHEN 1ltE lIOTOR
COCl.S TO A SAFE OPERA lING lEWPERA 1\JRE.
SEAL CHAMBER
lHE lIOTOR SHALL BE PROTECTED BY TWO (2) ROTARY SHAFT SEALS lIOUNlED .. TANOD.I WI'Ill AN 01.
FUED CHNo&R SEPARAlING lHE SEALS. 1HE SEALS SHALL HA~ CARllON AND CERMlIC SEAL rACES
DlAlIOND LAPPED TO A TOlERANCE OF ONE UGHT BAND. llETAL PARTS AND SPRIlGS rOR SEALS SHALL BE
STAINLESS SlEEL. AN ELEC1RICAl SENSING PRQ8E SHALL BE WOUNlED .. THE SEAL CHAWIlER TO DETECT
ANY WA lER LEAKAGE PAST 1HE LOWER SEAL.
GRINDER ASSEMBLY & CONSTRUCTION
lHE GRtIOER ASSDB.Y SHALL CO$ST OF A ROTAllNG RADIAL CUTTER AND A STAlIONARY SHllEDllI.c
RING. AND SHALL BE WOUNlED lllREC'llY BELOW THE \IOWlE PASSAGE. THE ROTAllNG CUTTER SHALL BE
'MlEADED ONTO THE STAINLESS SlEEl. SHAFT AND SHAl.l. BE LOCKm 'lI'Ill A SCREW AND WASHER. THE
ST A llONARY SHREDOlNG RWG SHALL BE PRESSED ONTO AN IRON HOl..lllNG F\..ANClE f'OR [AS'( RElIOVAL.. 1ltE
FlANOE SHALL BE PROWlED 'lI'Ill TAPPED BAO<-(J'f HOLES so 'IllAT SCREWS CAN BE USED TO PUSH THE
SHREDOlNG RIlG f'ROW THE HOUSING. BO'Ill 1HE RADIAL CUTTER AND SHREDOlNG RING SHALL BE
IlElIOVABlE f'ROW 1HE OUTSIDE 'I'lllOUT lllSWAN1\JHG PUMP. GRINDER ASSaIBI. Y SHALL BE OF SUCH
CONSTRUC1lON 'IllA T NO a..EARANCE AO.aJS1WENTS ARE REQUIRED WHEN ASSDolIll..lNG. ALL GRlNOlHG OF
SOUDS SHALL BE f'ROW 1HE ACl1Qll OF lHE RADIAL CUTTER AGAINST 1ltE SHllEDllI.c flING. 1HE RADIAL
CUTTER AND SHREDDING RIHC SHALL BE OF f440 STAINlESS S1EEl. HARDENED TO 58-80 ROCKWEU. c.
PUMP IMPELLER
lHE PIM' IIoIPEU..ER SHAl.l. BE OF lHE RECESSED TYPE TO PROWl[ AN OPEN UN08SlRUClED PASSAGE
lHROUGH lHE \IOWlE f'OR THE GROUND SQJDS. THE IlIIPELLER SHALL BE CONSTRUClED OF CAST IRON
AND SHALL HA~ PUUP OUT VANES ON 1ltE BAQ( $I)[ OF THE IlIIPELLER TO KEEP SOUDS f'ROW LOWER SEAL
AND REDUCE PRESSUllE AT 'THE SEAL rACES. IlIIPELLER SHALL BE 1HllEADED ONTO 1HE STAINLESS S1EEl.
SHAFT.
PUMP & MOTOR CASTINGS
ALL IRON CASllNG SHALL BE OF HIGH 1ENSI.E CAST IRON AND SHALL BE PROPEJllY a.EANEIl, PRE-lREAlED
WI'Ill CHROIIC RINSE, AND PAlNlED 'lI'Ill A HIGH QUALlTY ENAWEI.. PAINT. ALL PUMP COWPONDlTS 'IllAT ARE
NOT CAST IRON OR STAINl.LSS S1EEl. SHALL BE GALIIANlZED OR PAlNlED 'lI'Ill 1lAl<ED-0N EPOllY. ALL
rASTENERS SHALL BE I3l'2 STAINl.ESS S1EEl..
WET WELL
SHALL BE A FlLAWDlT WOUND FlIIERGL.ASS BASIN USING A COMlERQAL GRADE OF GlASS FIBER HA'llNG A
COUPUNG AGENT lHCH WIU. PRO\IIDE A SUITABlE BOND IlET'llEEN 1HE GlASS RElNFORCDIENT AND 'THE
RESlIl. 'THE lAIINAlE SHALL COfllSlST OF AN INNER SURFACE. AN IN1ERIOR LAYER. AND AN EXlERIOR LAYER
OF lAIINA lE BODY. 'THE INNER SURFACE SHALL BE FllEE OF CRACKS AND CRAZIHC WI'Ill A SWOO'lll FlNSH.
SOllIE WA\IIHESS IS PERWISSI8LE AS LONG AS 1HE SURFACE IS SWOO'lll AND FllEE OF PITS. IlET'llEEN 0.010
AND 0.020 INOES OF RESIN-RICH SURFACE SHALL BE PROWlED. 1HE IIASIN SHALL BE I'ROIo<<lED 'lI'Ill AN
ANll-nOATAllON RIHC TO PRE\€NT RISING.
VALVE BOX
SHALL BE a>c lIOOEl 'ttI3242 F1IlERGlASS VAL~ BOX WITH U.s. rOUNDRY APS-HIO AI.lMINUW VAL~ BOX
~. VAL~ BOX SHALL BE PRE-Pl.lA&D USING ALL SCHDUl.E 110 PIIC PIPIlO AND FlTllNGS. AND SHALL
INCWOE TWO (2). 2. SCHEDULE 110 P\IC BAU. CHEac VAL't€$, AND 1HREE (3), 2. SCHEDULE 110 PIIC
GAlE VAL~ (ONE (1) 2. GAlE VALlIE IS SUPPUED AS AN D.lERGENCY PUWP-OUl). PIIC PlPlNO ..
VAL~ BOX. AND WET WELl SHALL BE CONNEClED AND HElD IN PlACE BYa>c lIOOEl 32 RESIlIENT WOUNT
SEAUNG SYS1DI TO CXM'OISAlE rOR POSSB.E UNE\Gl SETlUNG OF IIASIN OR VAL~ BOX. SYS1DI SHALL
BE PRESSURE lES1ED AT 1!lO P.S.L PRIOR TO SHAlENT.
ALUMINUM HATCH COVERS
SHAU. BE rAllRlCAlED f'ROW 1/4. ALlJMINUW DlAlIONO Pl.A1E AND BUIlT TO WI'IllSTAND A LOAD OF 1!lO LB.
p.s.r. AND SHALL BE WANUrAClURED BY U.s. rOUNDRY, HAWDAY. OR EOUAl...
STAINLESS S1EEl. BC11'5, NUTS AND HINGES - LOCKING STAPLE.
FLOA TS
SHALL BE ANCHOR saEH1lF1C S3ONO ROTO-nOATS OR EQUAL..
ACCESSORIES
-- STAINLESS S1EEl. UPPER GUIDE 1lRAQ([1S
-- STAINLESS SlEEl. GUIDE RAl.S
-- STAINLESS SlEEl. CA8lL RAO<
-- STAINlESS S1EEl. I.FT CA8LES
ANTI-FLOATATION
CONCRElE IS RECOUWENDED TO PRE\€NT nOATAllON OF 1HE F1IlERGlASS IIASIN. THE rOllOWlNG US1S
1ltE CUBIC FEET REQUIRED PER FOOT OF BASIN DEPl)l.
BASIN
DIAMETER
24-
30'
36-
48
60'
CUBIC FEET OF CONCRETE REQUIRED
PER FOOT OF BASIN DEPTH
2
3.!S
5
8.5
12
For Complete T echn ical Assistance Call:
Custom Pump & Controls, Inc.
6034 Jet Port Industrial Blvd,
Tampa FL 33634
TEL:
FAX:
(813) 886-6255
(813) 886-3508
* ENGINEERING/SURVEYING L1C. # 3763/LB3763
DESIGNED BFV
ORA WN ....
CHECK JENi
NO.
REVISIONS
BY
JOIoW B. WEBB, P.E.
APPR'D. PROJECT ENGINEER
DATE
~r=
IMJIS Il8IEMBL ---: ==
t;:~ ~
1.......
;~
~<.,#J, '
~;tfi.
,- '51: 0'
' (J 4jJ ?
e~.- .:.i_t. ~ '. J' .' ('~...~':"
6"]' .~.t (..~J~...,.~I>
.~>.- ,~,..", '..'~' (,~
.(.1' > . .l~ "~,,. A'>
<. rl)/>.I) Gf-'
."..'..:(.....':'f G~
J(.,~~,:) 'if
d.1r! -~~
~'jJ; .:~~,~
i"~W!", u./~.
oJ'f J cr, _ t:.<:o)i.{fl,
'~.. ...'.'~~ (.. ;~~'.M.. .f
({r-. -;11 ., (~:
';<.,'.~,;:(;~
.,~,. '.,'
:--...2....:; _,-'
i-.i. ,"~ "" <:;.}jf
"'[c;;l~, '.J
\
/'J ~~J'
;JJ ti;. <lti;,..,,'i
;>'~.: . ~?>~1Y'
" ):;:"5" <~'~",1
~. -A." '''' . :~;:h
j;;.,,2;~ ,;';~:"
; >''!'\ ' :r2,
,~.! ''''",'J . . ,"
:'-:;~f;4f;"'~~ "~~.
t~?,~c ~;~~:rl
t;t~;~3T~i ,;, ;;ii~,
~(~, :oW> (~1~,
~~~:P ,;:)ji~"
-~,:-~:.J
..LL
!EII\a DISCOIIECT """'"
,,- CXlN1RClL PNlEL
:rr---
1lP ELEV, 45.00
STMUSS 51m 1
~ RAQ(
2" PYC WHT ~
L..-
k~
~2"n
:J~~
~
rll
1lY. ELEV, 4150'
_ WA1EIt IUIIM ELEV. 42.00'
LAO ~ ON ELEV.
41.80
I..EAII ~ ON ELEV.
4Cl.1IO'
PUIIPS r:n ELEV.
<<LOO'
BOmlII ELfV. 31.00'
r--
I. I ·
(f)
(f)
u
>
0....
~'\""~
?0f vo ."
~ r.~~ ~<:f
(:l ~jjc:t}' .., .',>1
'~~"'W.
~~~
I::ro...
I
~
c.~
"'.;,e ,.n
Cl':")f.
~ ~ V>
(~ ,:;
~~d'~) ~..
~w
~~~..~
~>> U'
~ :~"~ .'
~-(';,
~'Jj' .
''P C?
,..,. v>'
\:t"~
<D
.....r.:
-....c:
:: II
.......r.:
-.....a!:
o
n'
lP
-
-- .......:!!
~~~ ~:-
1lPS-48 ALUMIIUIII
HA 1tH COlIER
w/ 24. . 31. ACa:SS
DOOR
'-
'"
U.s. FOUNDRY ~1.
VAL~ BOX CCMR
W/24. . 34" ACUSS DOOR
aj~
( .,
'.,~,/:') VI ::?~' '.
ll' ". '''.'
~ , <
~'Wi
A~
;:9>'""., .; Of'
~. ~ t,:~~~
~~&~.).. .J{
'~~~;;>,
tll~~ :~
.~ ~v>a~? Pv>~
Jr~'" .,' ~ V> c~~ ~ ~~ ~>lt V>a r
&~~ wf~ :r4l~
.~;> -
~:l;t 3t.~
", ''>p _1}~>
2'P;'f;C c-o ~';~?
~.~ 1l ~.~ .~
ii~" '.' w' ({F~
~"J)wr
?:W.~:::J
~<tlv.., .
LANDSCAPING:
u.s. ~
-~
HA 1Q4 CXMII
wI 24. . .. ACCOS
DOOIl
^ r~GUIlE51m
II ~~
1" 1 --J
U.s. _ _1110
~ YALIIt lIOll CXMII
WI 24" . 34. ACCDS DOOIl
r-----t
STMUSS S1ED.
l.FT CMLD
~=~= ~ :;;;;'
~ a!' IIClllEL \IIJ242
~ YALIIt _
1.. - :;r...
=v- / \~ r-- \. ,,:V'___ =-'IO~_
o:t...! ~, \.. .' \ PIILD 1lITM.UD IV COII1ltM:1al
I ::v ~ 4-:-. '. .....~:.:;:..;-:~.: tr1E/~AL~PYC
'- 2.5" SCICDUI.E III PYC
2" PYC 1'-_ IIIU. QtEQC YALIIt
(_ ON IIMIl II YALIIt _
;.._ PIILD
_ II IlI'PUED BY
CXlIITlIAC'ftlR)
2.,' __ PH
SCICDUI.E III PYC
c
(
_ .-ASS
IIMIl
I. S1'~
GUIlE IlM.S
NOTE:
c
(
IMJIS IIClllEL
IllIllD-I211
l.FT-ouT
IIAI. S'ISTDl
Cancnle f1Iot _ 1:1 _
FIokI __ toy _
A ~ /NlTI-f\.QATA1lON MlO
I~~: ~ ~"""eT
. I .1'..... ......
1. CONCRETE ANTI-FLOATATION RING
SHALL BE A MINIMUM OF 18" IN DEPTH
AND 45 CUBIC FEET Of CONCRETE
41"
fAt"
F&RQASS BASIN M7H E-LINE VAL\f:' BOX
APPROVED FOR JOHN B. WEBB
a;:6V~
{AIG. PRC . ENGEi. FLORIDA 19951
ATE:" IF/Uj
./ /
!oIm I!. WdiJ It AsNkillfes, lItt:
cwa. a ENVRONMENTAL CONSUL TMJ ENGH:ERS
926 S. DEINNG ~ WINTER PARK, FLOR6JA S271JS
ENCLOSURE MA T X FG.
H.P. 2 PHASE 1
SERVICE SYSTEM 3 WIRE
SS
VOL TAGE 208
x 4 WIRE
GPS
· NOTE: CONlRACTOR TO FIELD W:R1FY PHASE AND \fOlTAGE
<.?
Z
~
0:::
<(
0...
l.J..
o
w
<.?
o
w
I I
I I
ALARM BEACON
~
I
~
o
<l>
GENERATOR
RECEPTAa.E
r--
ICEII
~-
-'---
~ --'--IJ ~
=1
o
-,..--
8
8
~.;.
o
D
o
<l>
LS
FRONT ~
l5
NEWA RATED OUTDOOR ENCLOSURE WITH MATERIAl COWPOSlnON AS SPECIFIED BELOW
CONTROL PANEL
PER D.E,P, REQUIREMENTS
TOTAL
HEAD
IN
Meters Feet
120
35-
30-
100
25-
80
20-
60
5~ FEET - -'- -- -
15-
40
10-
20
5-
FEET - -~ -- -
0-
o
o
I
o
WINTER SPRINGS AUTO SERVICE CENTER
MIRANDA TOWING
ICS tDJSTAIAL -ca.t.ERCIAL STRUCTURES, INC.
SPECIFICA nONS FOR DUPLEX D.E.P. TYPE CONTROL PANEL
EACH PANEL SHALL CONTROL TWO
2
PHASE. 60 Hz PUMPS.
208
HP,
VOL T,
A NEUTRAL SHALL BE SUPPLIED TO THE PANEL FOR 120 VOLT CONTROL POWER.
PANEL ENCLOSURE
ENCLOSURE SHALL BE NEMA 4X . F ABRICA TED FROM X FIBERGLASS.
STAINLESS STEEL. ALUMINUM, OR GALVANIZED
PAINTED STEEL. OUTER DOOR SHALL HAVE HINGES AND MEANS FORPADLOCKING, INNER DEADFRONT DOOR SHALL BE
5052-H32 ALLOY ALUMINUM. ALL MOUNTING HOLES SHALL BE DRILLED AND TAPPED, SELF TAPPING SCREW NOT ACCEPTABLE.
ALL BOLTS, NUTS. LOCK WASHERS, AND MACHINE SCREWS SHALL BE STAINLESS STEEL.
THE FOLLOWING MAJOR COMPONENTS ARE REQUIRED:
1) MAIN BREAKER
2 EMERGENCY BREAKER AND GENERATOR RECEPTACLE-RUSSELL STOll
3 PUMP BREAKERS
4 CONTROL CIRCUIT BREAKER
5 ALTERNATOR
6 HIGH LEVEL FLASHING ALARM LIGHT
7 HIGH LEVEL HORN ALARM WITH SILENCE - WHEN SILENCE LIGHT STAYS ON
8 LIGHTNING ARRESTOR
9 SURGE SUPPRESOR
10) PHASE/UNDER VOLTAGE MONITORING RELAY IF 3 PHASE. UNDER VOLTAGE MONITORING RELAY IF SINGLE PHASE
11) NEMA RATED MOTOR STARTERS WITH OVERLOAD PROTECTION FOR ALL POWER LEGS
12) ELAPSE TIME METERS
13) CAPACITORS AND START-RELAYS AS APPROVED FOR MYERS PUMPS ON SINGLE PHASE SYSTEMS.
TYPICAL SEQUENCE OF OPERATION:
ON RISE LEVEL:
LOWEST FLOAT WILL CLOSE CIRCUIT TO RELAY. LEAD PUMP ON FLOAT CLOSES TO BRING LEAD PUMP ON.
IF LEAD DOES NOT RECEDE AND CONTINUES TO RISE. THE LAG FLOAT WILL CLOSE AND BRING ON THE LAG
PUMP. FURTHER RISING OF LEVEL IN WETWELL WILL CLOSE 4TH FLOAT (HIGH LEVEL) AND ACTIVATE THE
HIGH LEVEL ALARM LIGHT AND HORNS.
ON F AWNG LEVEL:
ALL PUMPS WILL DE-ENERGIZE AT THE OPENING OF THE LOWEST (OFF) FLOAT
CONTROL CIRCUITRY WILL BE SUCH THAT NO FLOAT WILL DEPEND ON ANOTHER FLOAT FOR ITS CONTROL POWER.
CONTROL PANEL SCHEMATICS, IN PLASTIC LAMINATE, IS TO BE AFFIXED TO THE INSIDE OF THE OUTER DOOR.
ALL WIRING SHALL BE NUMBERED.
IN THE EVENT THE PUMPS BEING FURNISHED REQUIRE SEAL FAILURE COMPONENTS AND INDICATION TO
VALIDATE WARRANTY, THESE COMPONENTS SHALL BE FURNISHED AS REQUIRED,
ALL COMPONENT LABELS SHALL BE OF THE LAZER PRINTED MYLAR PLASTIC LABELS.
A 24 HOUR EMERGENCY TELEPHONE CONTACT SHALL BE DISPLAYED BY THE OWNER.
NOTE:
1. PROVIDE .RL/OO36X GENERATOR RECEPTACLE
PER CITY OF WINTER SPRINGS.
SUBMERSIBLE GRINDER PUMPS
MODEL: WGL20-01
SPEED: 3450 RPM
DATE: June 06. 2001
PUMP PERFORMANCE CURVE
CATALOG CURVE
WGL20-01
5,000" 35 GPM @ 53,00 FT.
.........."--.
......................~
.... ----....
".....
~YSTE~ POIN
......... '-... SYS
- -I- -- ~'-
........, P
- -
....
-
J.
- -
_ ~UNOU POIN_
- -- -- -
-
-
~ ~
5
10
15
20
25
30
35
35 GPM
40
40 GPM
45 U.S. Gallons
I
20
I I
40 60
FLOW PER MINUTE
I
80
Liters
LIFT STATION DETAILS
DATE
JUNE, 2003
ENGR'S. PROJECT
107-01
SCALE
SHEET
OF7
C-5
N. T.S.
MORTAR \ /' 3/4" EXPANSION FIllER
O 8J ~..m.., 8J 0
..- ". .- "..- ...- ".
.. .. .. .. .. ..
~.t~ ~ ~.t~
"'!. II
.: _ ,.J.----
I.!""-
....J
....J
~
<-'
z
~
::>
CD
-<
La.J
o
-<
5
2 NO.5 CONT. Fill TOP
COARSE W / CONC.
/8. CltU WI TEXTURED PAINT
t-
V)
La.J
::L
<-'
:I:
CAULK
NOTE: PRO'v1DE EXPANSION AT EVERY 4 CONTROL JOINTS
CMU WALL EXPANSION JOINTS
~
o
CD
-<
Z
:i
<c
MORTAR \
/' TAR PAPER
O rn:~~":. ')~~: rn:~~"~ 0
...- ...- .. .-
-. -.. ... ".
, -U- '
'- CAULK
NOTE: PRO'v1DE CONTROL JOINT AT 20' O.C.
, ,
. "
CMU WALL CONTROL JOINT
/PROPERTY LINE
OR RIGHT-Of-WAY
--
a:::
~La.J
CDLa.J
Z
CONTRACTOR TO SUBMIT 8 ~
EXIST. ELEVATIONS A T ~ ~
GRADE 10' O.C. ALONG ~ ~
R/W WITH CONSTRUCTION ~ ~
DRAWINGS Of WAll (f) g
-<~
(I)
RNI~ :~E -\ .
I~~ '.
I
2- DIA. PVC WEEP HOLE IN W LL
ALONG REAR Pl SPACED 10' .C.
PIPE INVERT 44.00'
.,
-
-. .-
,~ "'~
- -.-
.
o
I
..
a.. f Al T. HOOK DIRECTION
".:5
I ~ ~ '. {TO BE DETERMINED
- 0 t- ' ~ BY STRUCTURAL ENGINEER
'. __,:' ,,: ". ,~:' : .." ,~: "', ',i ,",' :, :. '.:.' ~ TO BE DETERMINED
.:....::.,.. ~, ..,'..1 :'. ':'.-..' ~':.~' BY STRUCTURAL ENGINEER
I. " . ,_'u-:-:I. ' r'I" "
.. \II .. #." .. .. ..
~
.. .-.
.-.. .... ......
:. ..
:
.. ..- "..:-.... -: ...".- -.. ..
I TO BE DETERMINED
JBY STRUCTURAL ENGINEER
NATURAL GROUND COMPACTED TO 98%'-./ WALL SECTION
DENSITY BY MODIFIED PROCTOR
3/4"=1'-0"
NOTE:
OWNER TO PRO'v1DE STRUCTURAL ENGINEERING
CALCULATIONS BY FLORIDA LICENSE P.E. FOR
CMU SCREEN WALL.
3"
CD CMU SCREEN WALL
NTS
~
.........
0::
CL
26'
PARKING 2' 12' 12' 2' 14'
WHERE REQUIRED ROADWA Y ROADWA Y
SEE PLAN
STD. C~~ ~ GUiRv f 1 1/2" COMPo ASPHrr. TYPE I
- l!... J 1/4" ~R F~T/ _ 'i4" PER FOOT +-
~ ~11111111111111111111111111111 II ~
"
,
.,.., ..'
10" STABILIZED SUBGRADE -
FBV 75 PSI
'-- 8" lIMEROCK BASE
<<>> 98% DENSITY
(MODIFIED PROCTOR)
NOTE: CONC.
CURB TO BE
3000 PSI-
CLASS "A"
@ FRONTAGE ROAD CROSS-SECTlON B-B
NTS
'I,: ..~.: 'I" 2~ 18. ;I
.:., ;> ::~3.R . K
N _ I--- '--'-'- "-'"-- ' . , 7'
- ~.',' f' . .& .' , .'
, ".. " ~. ' . ',.' It ."..
~ ~~""&',:. '~',:: ,: :-'--'..,,:":.,,/.?'
, .. " .1' .. & ' -- " r
:. &" I .;." .. ~ 1 ..... ".:" ".-'.." Do,. ". :. ".. ~,
PAVEMENT
-r-
12- 8-
....................
12-
.
(Q
I
I
STABILIZED SUBGRADE
-I---
............................................................................................
.......................................................................................................
....................................................................................................
.
(Q
'::::::::::::. STABILIZED SUBGRADE '::.':::::::::.'::::::::::::::::::::::::
..................................................................................................
............................................................................................................
..................................................................................................
-'---
@ STD. CURB AND GUTTER
NTS
* ENGINEERING/SURVEYING L1C. # 3763/LB3763
& 7/8/03
DESIGNED F!IFV
DEE J3W DRAWN UUP
CHECK JNI
ADD GRADE NOTE AND REVISED SUBBASE DETAll@
NO. DA TE
REVISIONS
JOI-t4 B. WEBB, P.E.
BY APPR'D. PROJECT ENGINEER
.
,1.-
d
7/8" DIA. HOLE
.
~....'b
o
,1.
o
.
.....~
~
4"
11
( 1\ ~.
///// '/////
v
18- -3/4-DIA. STEEL
ROD
.
N
-
----'I<"
NOTE:
CONCRETE SHAll BE 3000 PSI 28 DAY STRENGTH
@ PRECAST CONC. WHEEL STOP
NTS
FIN, GRADE
6" L3/4" R (TYP.)
.. .;~ .~.. -...
...... ..... .....: W
.. ~.., -.....'0 ..
.. ,," .......: ....:
~.:..{... ~..
.. .. ... - .. .. ,
! : .. .,. ..
'/ ./(; ~ "',' ...~ ..' :::~" ,:,":' ...:::. :,~.:..,
.. f.... L"~.",, ..'.... .. .. ...- ... ...
~ . 3000 PSI CONC.
'W5
~
~~
~
~
.n, .V
NOTE:
1. PROVIDE 1/8" - 1/4" CONTROL JOINTS @ 10' O.C.
2. PROVIDE 6" STABILIZED SUBGRADE BENEATH
THE CURB.
@ CONC. VERTICAL CURB
NTS
5' AND 6' ~I
LI- .liL
'" w T-tr:'~( ~~
PRO'v1DE 1" DEEP CONTRACTION JOINT EVERY 4'
AND EXPANSION JOINT EVERY 20' FOR SIDEWALKS
@ CONC. SIDEWALK DETAIL
f----soo...../
iot
I
I
I-
~otr
r'-
I-
~- ~
u, '!S,
,..; 1>
- '-I-- -
'\
~
I.~
CDu..
F~
00
:ice
4:
?:
-,---
~~ M
'it1 ':>.
... " I J
~~1E ~ 3" lHlCK RElNfOOCEO I j
1m 6 x6- 10/10 EDED IRE rAIRC u1
I
,-SOD~
PLAN
5' SOD
4: 1
c
6. ~c SLAB
r~ U~~
. '/'
~~~ (~
,. ROO ~ ~ 5' 1.{~
I .
or
/
~ ~CRE1E VARIES
E
ROUND CONCRElE PIPE SECTION
NOTE:
1. LET1ERS REfER TO r.D.OJ. DE~
STANDARDS "OIMEN9ONS AND OOANTlllES
CHART ~ INDEX NUMBER 272 &: 273.
o
15'
18-
24'
YJ"
36"
B C
4.09' 6.36
5.12 7.48
7.18 9.71
9,25' 11.95
11.31 14.81
E r ..
4.03 8' 4.63
5.03 9 4.92
7.03 11 5.50
9.03 13 6.08
11.03' 15' 6.67
N
1.19
1.21
1.25
1.29'
1.33"
A
2.27
2.36
2.53
2.70'
2.87
(j) CONC. MITERED END SECTlON
NTS
~ /L ~fr~:~ -
mD I DOORS \\1TH
COLORS FOR flORIDA SIGNS:
REFlECTI~ BLUE
REflECTIVE ~ITE
SEE DETAIL THIS
SHEET FOR RESERVED
PARKING SlGNAGE
REQUIREMENTS ~
"'= -L2'
1
1%
I. 12'-0- / l 5i' l
CD
0:
. ::>
o (.)
I
Co
-
'1
-,
-
2 4"
I ~.~~ ~JU;
lB" ~ITE
DIAGONAL
STRIPING
. 24- O.C.
@ HANDICAP STRIPING DEl AIL
NTS
1-1/2" (2" IN FOOT R/W) FOOT TYPE S-III
ASPHALT SURFACE COURSE
8" (10" IN FOOT R/W) lIMEROCK BASE COURSE (cOMPACTED
TO 98% MODIFIED PROCTOR TEST MAXIMUM
DRY DENSITY, lBR 100
- 10- (12" IN FOOT R/W) STABILIZED SUB-BASE CCOURSE
COMPACTED TO 98~ MODIFIED PROCTOR TEST MA\XIMUM
DRY DENSITY, lBR 40, OR FBV 75 PSI
I
I
W~
...
l' >
~
@ TYP. PARKING PAVEMENT SECTION
NTS
\t. IV IV . ~ \It.
.~~~~ ~~~"7-"
//,,/%,,%; "~,, /
,." ~ *,,<,
UNDISTURB~ ~~-I---- ~l'
EARTH "/.~ J..(~~ SLOPE - 2:1 MIN
~ . ~ OR SHORIING
I( ~
(I) "
w
~~-
"0"+24" MAX
~ 1 ""
UTILITY SER'v1CE -< ~
lATERAL - _________ ~ r90' ~
~,...L..~ ~'
.{,~A~~
">>>-/ A 7'l' jI'"
',,,<,,,~
COMP AC1ED BACKFILL -
SEE COMPOSITE UmllTY
PLAN, UTlUTY
SPECIFICATIONS A~D
PROFILE PLANS
NOTE 1
NOTE 1
DEPTH FOR REMOVAL Of UNSUITABlE MATERIAL SHALL
BE AS REQUIRED TO REACH SUIT ABLE FOUNDATION
AND SHALL BE IN ACCORDANCE WITH ASTM 0- 2321
@) TYPICAL TRENCH DETAIL
NTS
VERTICAL 15 REBAR AT
EACH CORNER. (TWico!)
I-
12'
-I
a:::
-<
m
L.J
a:::
10
.....
....J
-<
t-
~
N
~
::L
!:t!t~.;~!t~:;Jt:ff;~~iJiJ.~~~
'. :..~.-.-,:ENCLOSED.,,_ .... .'.
,:~':;:" ::O'UM'P'STER .p AD:~. "~. ::;
.:.:~:;..~ ;.~.~..~ .~.: .::.~.:.1::a :~:~::~~ :.;. ~~;_. ~
-:1 .....:.~. ... ~.;. ....... -.~. :.- .-.....
:i~--~;'~~::~:..:i.~.: ~..:.:-/' ~~::.;:~~ .~~ ~~i~
~'.: SloPE PAD TO 'DRAIN ~;':::
.hti~J~;.>\;:~~:~;Jt{~;?
. .lt4'.. ...... ... I. . ... :~ .1.
. ~..:: :.. .:.: 4:.. :....;:.. .~.. :. .:....Z .i ....~ ..~
,.....
-
-
~
m
La.J
a:::
~
N
~ -
Z
o
N
~
::L
,.....
FILL CORNER CELLS ~
SECURE HEAVY DUTY
GA TE HINGES TO BLOCK
WALL 'MTH 1/2" ANCHOR
OR WEDGE BOLTS
STEEL FRAMES
PLAN VIEW
18" r-1 \"R
- FTP-26, l8XJO STD. - / ~
18"
1\" R ~1"
\" 1-- f-- PARKING BY
.8" DISABLED 12-
.8" PERMIT
.8- ONLY
1.5 SERIES 'C'
/'
- 1"
1....-
I
$ 250 FINE
-+
@ 84"
12 HANDICAP SIGNAGE NTS _t FIN. GRADE
(VERIFY /MEET CITY REQUIREMENTS)
STABILIZED MATERIAL
(SEE SOIL REPORT)
TOOLED EDGES
CONC. APRON \\1TH 6X6XW2.1XW2.1
W.W.F, (SEE CONC. PVtti'T. DET.)
15 CONT.
I
'f' ... - ,4' .
., ~ . '.4' 4
, ,', '.. - ..., '. . ... .. ~ :."
.. ", x .' I X . .,' x,
~~ ~ I\:( 4., " . " ': ,'..~.:', 4', . '4 .< >
i~ ./..::.:...~N
:II - ~':II.;w 1= 1--11 -WEll f. illl-II {!TJ7
~~l1Fr~~ I ~I ~g'
: Z
c.o~:
m
9"
@ CONCRETE APRON DETAIL
NTS
FRAME & SOLID LID. NEENAH NO R-1974-A
(ROUND) OR APPROVED EQUAL WITH ClEAR
OPENING EQUAL TO PIPE 1.0,
FINISHED PAVEMENT
~ERE REQUIRED 7
/ TROWEL-FINISH
r FINISHED GRADE
.:~~ ::.~<<i<<<<<<~
.. . . V' / 'i'>y"
. .. /. .
I ,"
:::::::::::::::::::::::::::::::::::.;,~;..
12" CONCRETE /
COLLAR 6" THK. ----./
z
(1)-
w~
a: :
~g
45' BEND
"
~=t~
.
}
SEWER/ORAIN U
WYE
\:45' BEND
@ CLEANOUT DETAIL '
NTS
POURED LINTEL BEAM REINFORCED
WITH (1) HORIZONTAL 15 REBAR (TYP.)
-~ ~
I....~
:. ....
~RTlCAL 15 REBAR
4' -C-C AND
AT CORNERS (TYP)
1:".
, .
~~
,.
. .
. '.
....
STANDARD 8-X16- CONCRETE BLOCK,
Fill ALL CORNER CELLS WITH 3000 PSI
CONCRETE, USE -PEA GRAVEL" SIZE
AGGREGATE MAX.
r 4- CONCRETE SlAB REINFORCED WITH
6X6-W10XW10 W
3000 PSI, 28 DAY CONCRETE, 40KSI STEEL
<c
";1-:'
.. ~.
~
.. .:
~ :
~
-I-
,: ~S:'~. ~~~~~ ~:;,.:..: ~;::~::. .:'-' ,::.'.::... \~ :::.:> ~ -;.:~,,:-. '::.~:::
->:.~:\;~":r::">' . NATURAL GROUND COMPACTED TO 98~
\ I DENSITY BY MODIFIED PROCTOR
\L (2) 15 REBAR, CONTlNOUS (TYPICAL)
SECllON VIEW
-'--
@ DUMPSTER DETAIL
NTS
NOTE:
1. OWMPSTER ENClOSURE TO MEET REQUIREMENTS OF OTY ORDINANCE #2002-13.
2. BWILDER TO COORDINATE DUMPSTER SIZE. lOCATION, ACCESS. ETC, WITH WASTE HAULER (Fl. RECYCLING)
3. BUILDER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS BY flORIDA LICENSE P.E.
FOR DUMPSTER ENCLOSURE.
APPROVED FOR JOHN B. WEBB
/L & ASSOCIATES, INC.
71'd"", g VAAA-
/ ~~:PJjr,'V'~!!' FlORIDA 19951
VOA I I
101m H. We/16 k As8Odllfes, l/rlt. *
cwa. a ENWIONMENTAL CONSl.L TMi ENGMEER8
926 8. DEIM<<J DRIVE, WNTER PARK, FLORIJA 32789
WINTER SPRINGS AUTO SERVICE CENTER
MIRANDA TOWING
ICS INDUSTRIAL -caJM:RCIAL STRUCTURES, Ne.
7-
CMU SCREEN WALL~I
~/
EL. 43.00' ~
VARIES
SOD SIDESLOPES TO N'M..
MAINT BERM
10' MIN.
~~
~
100-YR EL. 44.00'
25- YR EL. 43.39'
MEAN ANNUAL EL 41.81, 4
NWL EL. 40.00' 1 ~
-EL~ 37.00' EL. 37.:'~ i1'
~1 11
~
~ ~
Yh
EL. 44.00'
z~
.'"
~
a:::
E_
'V"/;y,>-,-v.'''''.
@ WET DETENTION POND SECTlON (SECTlON A-A)
NTS
~o(? .1. f-r .J III'
~, r I rl r ~I No..o4 Top &In J
.:. r No. 4 8t1ftwI &In
I r I r I If, I" Slope To III1Ioh N/JtIDMf CUj fllfh ~ Top fftldu
I L Nrt/ r 8t1ftwI CfttIItfer Or 'l ~1lIL r- ,.,.,
~~~ D-I~'r I~.,~~,
~ I LlM
- ~-
BrV D - r..
No. 4 &In ~
. r Ctrs.
.L:: Cf1nter Fill., (SH Note 6,,)
- 'EI?o
= No. 41. r err.. HoI'(z.
r a..t.,. -----..
'No. 40ltlf. &In ".r r No. o4. r Ctrs. Vert.
No. 5 &In
. ~ Ctrs.
(P_1de Horlz.
Hook QI TIntIt
End Of Top &/rJ .. _
"I
r I Ifllet
(lfll.t Top 7)ope 6
~I<<I( AbtJuI I)
I
~ ~A
FI/1.t EadI 8<<1Ic Cf1nter
RequIred ""." Round
8t1ftwI Or Rleer U..
rQ.o4.ro.ll.', -"
-5.5'0.11._
r-;
a (I/'Or go t .J-
L\ M Mil I
-(~ II
~
~~Q
~\
: ~
~ a
--.---- I- ~_\~.J
I 1D'" - IIf1'" \...
r y~A r~
1
G:j f'
d1~ ~I
I CIl'
a11l
II \T fI'
11." 1
--
1
r,;
L"
5'o(?
IO'-r
fStHl ewer ~
SECTION AA
TOP VIEW
f-I/'
To Be PrlId For I
As Qri . Gutter
F.L. Of Q/fter... \-1
~ ) ~
r'
I
I To Be PoIdtJr.,
As Qri .
10" ?oI
w
u..n. Of hll., CamnIt1!fofI
/
~ J Yo; Jj:
'~J~
~~
:::::: ~.
l!:::P"" ) lt~
--- -- .
"-(1'
Q/fter T",..nfofl
8'-(1'
,
I
,
I
.1. ~.I/' ,'O(?
I Q/fter T",..nfofl
~4!d
SECTION BB
(Qri hi'" Top Type 6 ~IotI, "Ifh Left Half)
1~&In
(0'-'11'" I'rlM
s,... 8e1WHfI N/JtIDMf
I.I1ng11utlltttl/ C...,
ThtIn r Cenfen)
~
SECTION PP
f f-lf'
;.,-~ ~
",N K ,,/
~~ ~: ,/~
~ r---v
'K
", .......
~1leo.Q/fter~I\':- I~.~ .
" 6nIN--;;. ~ ~
...
~ f'~ I go I
'- No. 5 &In I' :, go ,I/' go III~: : = &Irs
SECTION QQ . ~ Ctrs. -+- I
r V\ ~~
I ~. I " --
INLET TYPE 5
~
TOP MODIFICA nON FOR TYPE E CURB
SKETCHS SHOWING FRAME SEA T AND THROA 7 RECESS
@ CURB INLET TOPS TYPES 5 AND 6
NTS
(SEE FOOT INDEX #200 FOR INLET BOTTOMS)
FUTURE CURB AND
CUTlER CONSTRUCTION ~
"-10" - A \
1'-2" r
>
II
11
- ,,- GEOTEXTlLE
POST --........ /' MA TERIAL
a ......
EXISTING GROUND '" ~
"'~-
-- CO
....
S 2C'R OR AS SHO~ ON PLAN
~ ,1/2" EXP. .KINT
~II I
II
~
~
J-12" OF GEOTEXlllE
MATERIAL TO BE
TIED INTO GRADE
SILT BARRIER FENCE
-
-c I
-A -B
VAlLEY CUTlER I CURB AND CUTlER
r STRAW BALES
PINNED TO BERM
or
24~r ~1 18- MIN.
~I .,~ -
-~
- ....... EXISllNG GROUND
PLAN
I
~[I-
I
1'-10"
1'-2" I
~~
-:.~ 6.25" ~
3'-0. , I
BERM W / STRAW BALES
-
SECTION AA
\
)
SilTING BASIN
...~ 6" "-6. 1'-10"
,. i'-y~.;~ J
1"-2~1
~t,r lID]
.
CD
.
It)
~
TOR.
--.r-
'--
STRAW BALES AS
REQ'D. W/ 2-x2"
WOOD STAKES
8"
5'-0-
SECTION SS
<
'>
.
"l
STRA W BALES
f FINISHED GRADE
TOP OF SUB-BASE
II
-
~o/~
'I~
t\,~ ........1 6- , " 1'-10.
IY~
10'R
I rl. .J
._~
, 12-J}
2" x2" WOOD .J
STAKES
INLET W / STRAW BALES
tiQ1E
STRAW BALES TO BE REMOVED
PRIOR TO PLACEMENT OF
ASPHALT PAVEMENT AND
PLACEMENT OF SODDING
SWALES AND OPEN SPACE.
.
"l
.,...
SILTING BASIN
STORM STRUCTURES
.
CD I
I 8
3'-6-
I
I
I
SECTION CC
@ CONe. VALLEY GUTTER
NTS
@ EROSION CONlROL DETAILS
NTS
CONSTRUCTION DETAILS 1
DATE
JUNE, 2003
ENGR'S. PROJECT
107-01
SCALE
SHEET
OF7
C-6
N.T.S.
MINIMUM LENGTH OF RESTRAINED PIPE
TO BE INSTALLED ON EACH SIDE OF FiniNG
FITTINGS
PIPE SIZE (INCHES)
8
4
6
90' BEND
45' BEND
22 1/2' BEND
11 1/4' BEND
BRANCH OR TEE
DEAD ENDS
45
19
9
5
128
128
59
25
12
21
9
4
2
77
21
6
157
157
NOTES:
1. INSTALL FULL LENGTH JOINTS WITH TOTAL NUMBER OF JOINTS EQUAL TO OR GREATER THAN
SHO~ IN THE TABLE AND FOR THE TOTAL EQUIVALENT LENGTH REQUIRED.
2. WHERE TWO OR MORE FITTINGS ARE TOGETHER USE FITTINGS WHICH YIELD THE GREATEST NUMBER OF
RESTRAINED JOINTS.
3. CONTRACTOR SHALL SUBMIT FOR REVIEW AND COMMENT, DRAWINGS FOR RESTRAINED JOINT SYSTEM,
ENGINEER APPROVED SHOP DRAWINGS TO BE SUBMITTED TO THE CITY.
4. THRUST BLOCK AND RESTRAINING SEWER AND WATER MAIN SCHEDULES SHALL BE COMPLETED BY THE
ENGINEER, BASED ON ALL DESIGN CONSIDERATIONS INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
PIPE TYPE, SOIL BEARING CAPACITY, SOIL TYPE, DEPTH OF COVER, TEST PRESSURE, LAYING CONDITIONS,
SAFETY FACTOR.
5. THIS CHART WAS PREPARED BASED UPON THE 1992 DIPRA MANUAL FOR THRUST RESTRAINT OF
DUCTILE IRON PIPE. ASSUMING: (1.) 150 PSI WORKING PRESSURE, (2.) 3 FEET OF DEPTH, AND
(3.) LAYING CONDITION NO.3 FOR SAND/SILT BACKFILL.
CD RESTRAINED PIPE JOINTS TABLE
NTS
GROUT ~
FINISH GRADE ~ '\..
/FRAlIE AND CD-.rn USf 663-AB-MB
u~~.....
==
=~~ECCENTRIC CONICAL SECTION.
BRUSH BLAST AND RUB
INTERIOR AND JOINT
- ~ B SURF ACES. APPLY 2 COATS
WATER BASE EPOXY
(RED, THEN GRAY COLOR)
3-5 MILS OFT EACH.
l)L-- FlEX CONNECTOR
CONC. FILL ______ ~.o~.G
BENCHING ____~. ; :.)\ ../~~:; ~". l--- PRECAST CONC.
. . 4- ~ ~~~ . ASTM C478.
~I ..:...'..............~...; r r:~~A~f~~ILs
r ,,;,,:1 ~?:...:~-:-:.,;..:1 ~.;...:...:~-:-:~,,~.?;;..;.:". ',;'.;.P:." 1-9" UIN
...,,~.."t. :-....,-::-1 ~ .......:~.:;I.. :....,~-~ ~ ........::.. -: ..~:... !;.-..:'-<..-,\, .,:::s..;.. M .
~;'::~~~f:':'-0 ..1.:34:" ',f.~ '.~.. ..I.:t.'. .~_..~.~,."'":~, ,..:. T
NATURAL GROUND '~..... .!:r;....':~.~:f.:....'::;;';:...--r..: -,'::'\(:' No. 89 CRUSHED STONE
COMP ACTED TO 98~
DENSITY BY MODIFIED
PROCTOR
f7-.;J
':II~"
C
COURSES OF
BRICK OR CONC.
ADJUSTING
RINGS (5 MAX.)
.J
c::
'E
M.H. DEPTH
UP TO 12'
>12', < 18'
18' & DEEPER
A-
B
48"
60"
6"
8"
8"
-- 72"
-ENTIRE DEPTH EXCEPT CONE.
.. ECCENTRIC FLAT SLAB
TRANSITION TO CONE
SECTION IN ACCEPTABLE.
BACKFLOW PREVENTER
IN ACCORDANCE WITH
PLANS APPROVED BY
lHEOTY
GATE VALVE
TEST COCK (TYP.) ~~r--
THREADED
NIPPLE (TYP.) I
~-
Ii] l.,....
GATE VALVE
-~
I
~ ~ UNION
~ (2 REQUIRED)
(] ::::: !BO oBEND
"'l (2 REQUIRED)
6. I
MIN. I
NOTES:
1. PRECAST CONCRETE SHALL BE TYPE 2 CEMENT 4000 PSI
2. LIFT HOLES NOT PERMITTED THROUGH PRECAST SECTIONS.
3. ALL OPENINGS SHALL BE SEALED WITH NON-SHRINK GROUT.
4. INSTALL FLOW CHANNEL INSIDE MANHOlES,
5. SERVICE LATERALS SHALL BE PERMITTED DIRECTL Y INTO MANHOLES
AT INVERT ELEVATION ONLY.
6. REINFORCING STEEL PER ASTM C478-88a.
7. PROVIDE 5' x 5' x 12. CONCRETE COLLAR AROUND COVER FRAME,
W/4 #4 BARS E.W., IN UNPAVED AREAS WITHOUT CURBS OR OTHER
TRAFFIC BARRIERS. SLOPE TOP OF CONCRETE AWAY
FROM COVER FRAME.
8. MIN. 12" BEMEN WALL PENETRATIONS.
9. MIN. 50~ UNINTERRUPTED WALl AREA ON ANY HORIZONTAL PLANE.
~
~j ...."" -' .
.
1-
';/
FINAL GRADE
I 6"
I MIN.
o' I
z x
- <
::IE ::IE
a
N a
~~. .".. : i~~~".~'~ ~. ~ .~ I
~
~
~
....,
FROM
a
MAIN
6" CONCRETE SLAB W/ 14
BARS 12" O.C. BOTH WAYS
.
I
TO
$ER~CE
r
.
NOTES:
1. ALL PIPE AND FITTINGS 2" AND SMALLER SHALL BE
THREADED SCHEDULE 80 GALVANIZED STEEL OR BRASS.
2. ALL ABOVE GROUND PIPE AND ASSEMBLIES SHALL BE
PAINTED BLACK.
@ REDUCED PRESSURE BACKFLOW PREVENTER
NTS
SET TOP Of VALVE BOX -
TO FINISHED GRADE
r--~~~EA~~~S
(SEE DETAILS)
~,. ~~ ~STAIllE CAST IRlllN IX
SEE NOTE 2 - lIt\ VAL VE BOX ~
I'~ u
RESlUENT SEAT JJav'BOX SHALL REST ON
M J GATE VALVE Iilifi. BEDDING ROCK NOT
. . ~~ l:... ~ ON VALVE OR PIPE
WA TER~ ~ ---=::: AND SHALL BE
MAIN CENTERED ON
I" OPERATING NUT
o
~ )
FINISHED GRADE
Z
3i
;.,
6" BEDDING ROCKJ
NOTES:
1. PVC EXTENSIONS SHALL NOT BE USED ON VALVE BOX INSTALIlATlONo
2. THE ACTUATING NUT FOR DEEPER VALVES SHALL BE EXTENDE(D TO
COME UP TO 4 FOOT DEPTH BELOW FINISHED GRADE.
C
36-
36"
36"
@ GATE VALVE AND BOX DETAIL
NTS
o
8"
10"
14"
MANHOLE SIZE:
UP TO 24" PIPE = 48" t, UPTO 36" PIPE = 60" _, OVER 36" PIPE = 72" t.
@ STD, SANITARY MANHOLE DETAIL
NTS
8"
,"'.., ...~ ~
~ 8"
~"
.
XV /PAYEMENT
~., . · .1, · .. / /"/ ~ ~// 'l
.. .. .. ... .."/"/ '/ ,. "/
.' .. '.. .... ..: · '/"/:% ~ './- "i
.' .... . , .. '/ ~ '/ '~ ~ %
..f' .f' ... . "/'/"/"/ F
: ..:..:: ~ .... ...... .... f' ~,/." ...):: % 'l'.-h/'./-%
.... _.. ....,. /'/' /..' /. "/~/h,
-. "..." .
6.
12" I
I
STABIUZED SUBGRADE
12"
--
6"
.:.':::..::..:::" COMPACTED SUBGRADE '::::.":::::::.":::.'::.'.
@ CONC. RIBBON CURB
NTS
* ENGINEERING/SURVEYING Lie. # 3763/LB3763
DESIGNED f!IPI
DRAWN UUD
CHECK J8W
APPROVED FOR JOHN B. WEBB
~ ASSOCIATES, INC.
77" ''-' /f VAA4-
aGo PRQF. ENGR. FLORIDA 19951
ATE: 71lVro .3.
I I
NO. DA TE
JOfoW B. WEBB, P.E.
BY APPRoD. PROJECT ENGINEER
REVISIONS
It
::~
~~
---
8" BRICK OR
NON-REINFORCED
CONCRETE OR
6" REINFORCED
CONCRETE ~
f--
3'- .OR
4' -0. DIA
-L
(\
\ J
~
ONE CAGE 14 0 12" CTRS ....0:::::
BOTH WAYS IN CENTER 1/3 OF ........
CONCRETE WALL
!
a
CO
f
~
<0::
....,zw ~:::E
(/)OCl.wO:::l
~F(/)(/)C'!:::E
0:: Cl.o I- W 0 Z
...., ZIZ-
I -F :::E
1-'0 X
O~"'ZWO
< ....,OZ
~~~~~<
WCl.FF=w(/)(/)
Z~ZU""'WI-Z
...-:::lm(/)~O
-' 0:: lO-
a iFO(/)..,~
OO~~I-o::"'"
.1 IoE~o~
CO(/)U:::E::::ilJ...O
I-
ZZ
:::l0
I-F
UU
<Z
~~
Zo::
go
(/)
W....,
.. ~5
0:: I
....,Z
0<
Z:::E
:::llli
0::1-
OW
lJ...~
0- .
-0::<
<0"'"
Cl.lJ...
....,....,lIi
m~~
00::0
I-o.m
,....
m
< ,....
~ ~ in
~ ~
~ (/) ~
o ~ Cl.
~ ~ ....,
~ _ 0
:; :::E ~
~ ~ :::E
- 0
0:: m
.... \. -
\. \. ..
.. "'--#4 BARS 0 9- CTRS
BOTH WAYS
.. PERIPHERAL BARS OR STRAIGHT END EMBEDMENTS MAYBE USED
IN LIEU OF STANDARD HOOKS, IN ACCORDANCE WITH DETAILS
FOOT INDEX 201 SH 3 OF 5.
@ FOOT TYPE 'p' MANHOLE
NTS
'oIm H. We6IJ Ie. As8(J(in/es, lilt. *
CIVI. . ENWlONMENTAL CONSlL TMJ ENt1MEER8
926 S. DENM'KJ DRIVE, WNTER PARK. FLORDA 32789
~
FINISH GRADE
0: 1m
11~1r=lIF ~ .
o~
U:::I!
;.,
WATER MAIN \
II
I~
9
U-BRANCH FITIlNG
(1" X 3/4- X 3/4")
CURB STOP
2EA.
~~
~
BLUE POLYEJHYLENE
TUBING
TO METER BOX
ASSEMBLY
1. ALL FITTINGS SHALl BE BRASS WITH COt.tPRESSION/PACK JOINT TYPE CONNECTIONS.
2. NO SERVICE UNE SHALl TERt.fINATE UNDER A DRMWAY.
3. EACH SERVICE SHALl TERMINATE AT A CURB STOP(S) WHICH SIW..L BE BURRIED APPROXIMATELY
3' BELOW FINAL GRADE & SHALl BE ClEARLY MARKED WITH A 2- X 2" X 18" STAKE.
WITH THE TOP PAINTED BLUE AND MARKED WITH THE NUMBER OF BLDG. TO BE SERVED,
r
.
::IE
lJ...
I~
a..
I~
N
SEE FORCE MAIN CONSTRUCTION DRAWINGS ~
FOR CONSTRUCTION Of FORCE MAIN AND
CONNECTION TO CITY SYSTEM
~
I
>-
~
~ ~
o
I~
_ __ ~a.. ,.. .....
- - ~~
-,
--
>-
~
~
0::
CI
--
WINTER SPRINGS AUTO SERVICE CENTER
MIRANDA TOWING
ICS INDUSTRIAL -couMEACIAL STRUCllJRES, INC.
C(
II
a Z
CXl-
SEE GENERAL NOTES ~ ::IE
THIS SHEET
SANITARY/STORM
& SEWER REClAIM
WATER MAIN.
@) PIPE CROSSING DETAIL
NTS
CORPORATION
STOP (1"7 MN.)
zr
~
O:J
~
:.:
\,
BLUE POl YEJHYLENE
TUBING (1" MIN.)
SINGLE METER BOX
AND WATER METER
CURB STOP
(SEE NOTE 3)
CORPORATION
= ~NTED STOP (1"7MIN')
BLUE & WITH
V~
i j
POLYETHYLENE
TUBING (1" MIN.)
DOUBLE MmR BOX
AND WATER METER
CORPORATION STOP
& FITIlNG
(NORMALLY OPEN)
, AYNlA TYPE
~~ CC THREADS
u
.~ SADDLE ~
In
'~"Vfl
.. ~ ..
WATER t.tAIN .-J
111,
~ ro-
u
.
~
30 - 45' DEG.
(]) WA TEA SERVICE CONNECTION
NTS
~
D
~
1'1 ~
~
~
2
I
-,
,
. ,
2' x 4' X 6" THK. CONCRETE
PAD" w/I4 BAR ANCHORING
G9 O.C.E.W. COUPLING
~ am ....... I ANCHORING ELBOW
~+ 1.I'JII3HL
/~ 4N I :Gr~ ~ ~ M.J. TEE
( III III
/ (1-' III i 11I-
J_ "I
6. GATE VALVE (MJ) L WATER MAIN
FIRE HYDRANT - W/PUMPER NOZZLE
FACING PAVEMENT.
FIRE HYDRANT PLAN
LIMITED RIGHT -OF - WAY CONDITIONS
AS REQ'D.
PUMPER NOZZLE
FACING PAVEMENT ".. ~
18" x 18" x 6" 7 "'
CONCRETE COLLAR 18" ~IN.
W/4-14 BARS ~4" AX. ~
=i::;::
~~J~I~TED ___ :~. ;:-:;.. '.--;:"
24" x 24" x 6"
REINFORCED CONCRETE
SHEAR PAD. W/4-#4 BARS
E.W. .
M.J. HYDRANT
ANCHORING TEE
en
.....
0::
~ l~~
, I
~
JUL
~HI
.....
,\... _; ~>l
_ IJUL ~UL
fH~
.....
12" MIN.
~.
RESILIENT v.rDGE GATE ':1
VALVE AND BOX
(SEE DETAIL)
M.J. ANCHORING
PIPE
6" MINIMUM
NO. 89 CRUSHED STONE
NOTES:
1. FIRE HYDRANT SHALL BE SUPPLIED WITHOUT A WEEP HOLE,
OR WITH A PERMANENTLY PLUGGED WEEP HOLE.
2. SHEAR PAD AND VALVE COllAR SHALL BE A SINGLE 24" WIDE SLAB
WHEN LESS THAN 4' APART.
3. CLEARANCE BEMEN BOTTOM OF BOlTS AND TOP OF SHEAR PAD
SHALL BE 3" MINIMUM.
@ FIRE HYDRANT DETAIL
NTS
1
,,~
-
~~
~
I
~~
- ~
'-~
z
c
\.~
z
c
-
1
'-
~~
~ ./b!
,: - - ;-1- -
1"'1 ~ = --
I
I
-FM- - - -
EXlSnNG 6' fII ~
-,... -......-
-FM-
~
I
-
NEW~
r PUBUX
@ SEWER CONNECTION DETAIL
NTS
CONSTRUCTION DETAILS 2
DATE
JUNE, 2003
ENGR'S. PROJECT
107-01
SCALE
SHEET
OF7
C-7
N.T.S.
~
,.
REMAINDER OF LOT 1
JOE E, JOHNSTON'S SURVEY
D,8, 14 7, PAGE 221
S 51-15'00" W
S 51-26'59" W
(DEED)
(MEAS,)
291.30'
266.89'
..
0"
q:,<O
n-,. <0
"'V q:,.
00
C\JC\J
4" OAK _ _~" OAK
2" OA''- -8 OAK
/'\ -5" OAK
-5" OAK "10" OAK-1 ' 8AK
OAK " 5 OAK _ -1 AK
-4,'" QAK 6" OAK- - ,.(),.()
-2-i2-~KdAKS -5" OAK 2" OA
-5" 0 a,.
-4"
-8"
o
o
4J.O
o
-22" OAK
OAK
-3-10" 0
36.3'
... 1 STORY WOOD
- cO FRAME
26" OAK N FIN. FL.=45.74'
36,4'
00 co
00::: .
00 CD
~Q. ....
-21" OAK
-12' OAK
o
o~
-6" OAK
-6" OAK
o
~ -12" OAK_18'
0----,0
13" OAK_ L 4' CHAIN
_ -1 a" OAK FENCE
13" OAK
(l
~ ~
~ .~
-4" OAK
-6" OAK
14" OAK _ -4" OAK
-19" OAK
-7' OAK
-13" OAK
4" OAK 4" OAK
328~~4'
351.10'
PINE
-6"
6"
6"
N51e30'23"E
N51-15'OO"E
1 0" OAK
(MEAS.)
(DEED)
LOTS 2 & 3
JOE E. JOHNSTON'S SURVEY
D.8. 147, PAGE 221
GRAPHIC SCALE
30 0 15 30 60 120
~ I I I I
( IN FEET )
1 inch. = 30 ft.
TOPOGRAPHIC SURVEY OF
"s"
A
PART OF BLOCK
ABBREVIA TlONS THA T MA Y BE USED ON THIS SURVEY
Ac Acre C. Calculated D. DescrIption Hariz. Horizontal P.C. Point of Curvature R/W Right-of-Way U.S.G.S. U.S. GeologIcal
Asph C.B. Catch BasIn 0.1. Drop Inlet H.W. HIgh Water P.C.C. Point of Compound Curve Son. SanItary Survey
Asphalt CCR Certified Corner Dia Diameter Hyd Hydrant P.C.P. Permanent Con trol Point Sec. Section W. West
Ave Avenue S.R.
Record Dr Drive I.P. Iron Pipe P.I. Point of Intersection State Rood W.M. Water Main
AZ Azimuth
B.C. Bottle Cop C.G. Curb and Gutter E East L.B. LIcensed Business P.L.S. ProfessIonal Land Surveyor S.S. Sanitary Sewer W.V. Water Valve
Bose LIne C.I.P. Cost Iron PIpe EI ElevatIon North P.S.M. Pro fession 01 Surveyor and Mapper St. Street
B.L. Sty. Story 4- Internal angle
B/dg BuildIng C.M. Concrete Monument F.F.E. FIn Ish Floor ElevatIon M. Measured P.O.C. Point on Curve
Blvd Boulevard C.M.P. Corrugated Metal PIpe F.H. Fire Hydrant N.G.S. NotIonal GeodetIc Survey P.R.C. PoInt of Reverse Curve S.W. Sidewalk
B.M. Bench Mark Co. County FI Floor NGVD Notional Geodetic Vertical P.R.M. Permanent Reference Monument T. Tangent length 0 Benchmark
Bndry Boundary Cone Concrete F/L Flowline Datum P.T. Point of Tangency Twp TownshIp
Bot Bottom Coord Coordinate Fnd Found N/A Not applicable R- Radius length T.B.M. Temporary Bench Mark EI Section Corner
Brg Bearing Cor Corner Ft. Foot D.C. Orange County Rd. Rood Tel. Telephone 11
BW Barbed WIre C.P. Concrete Pipe Hdwl Headwall (P) Plot dimensions R.R. Railroad U.G. Underground Con trol Point
~
:e
ASPH~ T
DRIVIE
5"
ceo
w-
-
rI"')
~
..
ceo
11'0
~
:e
-5' OAK
~
0:::
~
:e
pp
OF D.R.
~
~
o
o
~
~
0\
o
t-= z
~ <
Q. S t-=
~ :2 ~
(J) Q.
W (J) I.L.
C) <
0 0::: 0
W C) IU
C)
0
W
~ en
r') w
~ a:::
. <(&
a::: >.
. 0
en 3:
"-
a:::
ORA WN BY: CAD DA TE: DATE
CHECKEJ) BY: COBY DRAMNC NO.: OWG.NO
FIELD DA TE: FLO FIELD BOOI<: FB
JOB Na: IN SHEET SN OF 1
REVISIONS: DESCRlpnON:
x
.. R.C.P.
a:::
~
r-
;:)
a
old
CURB INL
TOP=46.10
FLOWLINE=
E. INV.=38.
o
~
~
0:::
II
II
\ I~
II=~
lD
n
CURB INLET
I TOP=46.05
FLOWLlNE=45.14
N. INV.=34.74
II S. INV.=34.76
W. INV.=37.82
a:::
w
~ II
;:)
a
old II
II)
a:::
;:)
()
N
~
"-
0:::
MITCHELL'S SURVEY OF
THE
Description:
Commencing at the most Easterly corner of that part of block "B" of D.R. MITCHELL'S
SURVEY OF THE LEVY GRANT, as recorded in Plat Book 1, Page 5, in the office of the Clerk
of Circuit Court of Seminole County, Florida, lying South and West of the paved road leading
from Sanford to Oviedo; thence along the Southwesterly side of the paved road North 38
degrees 45 minutes West 1586.00 feet to a concrete monument for a point of beginning;
thence continuing North 38 degrees 45 minutes West 200.00 feet; thence South 51 degrees
15 minutes West 291.30 feet to the Southeasterly side of a dirt road; thence South 22
degrees 15 minutes East 208.80 feet; thence North 51 degrees 15 minutes East 351.10 feet
to the point of beginning.
Notes:
1. This is not a boundary survey. This is a topographic survey of a portion of block "B" of D.R. MITCHELL'S
SURVEY OF THE LEVY GRANT.
2. Vertical information is based on Seminole County Benchmark 437.37.01 being a PK nail and disk in the
Northeast corner of a parking lot in the Southwest corner of the intersection of S.R. 434 and Tuskawilla Road.
3. Bearings and North arrow are based on a map provided by the client. The bearing structure as shown
hereon is based on the westerly right-of-way of S.R. 434 being on a bearing of N38'46'16"W.
4. This survey is not intended to reflect or determine ownership.
5. The property shown hereon was not abstracted for easements, rights-of-way, or adjoiners of record.
6. No subsurface improvements, foundations or ground covered encroachments were located by this survey,
except as shown.
7. Field work was completed July 24, 2002.
8. Tree locations and boundary information is based on a survey by Franklin, Mizo, & Ried dated 8/13/01.
9. The property shown hereon is located in Flood Zone "c", as scaled from FIRM Flood Insurance Rate Map
Panel 135 of 260, Seminole County, Florida (Unincorporated Areas), Community Panel Number 120289 0135 B,
Effective Date May 5, 1981.
10. No part of this survey may be reproduced by photocopying, recording of by any other means, or stored,
processed or transmitted in or by any computer or any other systems without the prior written permission of
the surveyor. Copies of this plan without an original signature and impression seal are not valid.
11. Data Sources:
-Florida Dept. of Transportation
State Project No. 77070-3516 Sheets 32 and 33
State Project No. 77070-2516 Sheet 8
-Flood insurance Rate Map Panel 135 of 260, Seminole County, Florida, (Unincorporated Areas), Community
Panel Number 120289 0135 B, Effective Date May 5, 1981.
-Boundary Survey by Franklin, Mizo, & Ried Dated 3/02/01 and Revised 8/13/01.
LEVY GRANT
~,
LAND SURVEYING DIVISION OF
ffdut 1!. We66 k Assodlltes, lHC.
CIVIL & ENVIRONMENTAL CONSULTING ENGINEERS
925 S, DENNING DRIVE
WINTER PARK, FLORIDA 32789
PH: (407) 622-9322 FAX: (407) 622-9325
EMAIL: WE88ENGR@AOL.COM
MIRANDA'S TOWING
INDUSTRIAL COMMERCIAL STRUCTURES, INC.