HomeMy WebLinkAbout2006 05 22 Informational 503 Consumer Confidence Report
COMMISSION AGENDA
ITEM 503
CONSENT
INFORMATIONAL X
PUBLIC HEARING
REGULAR
May 22, 2006
Meeting
MGR/DEPT
Authorization
REQUEST: Utility Department Providing the City Commission with a copy of the Consumer
Confidence Report that will be sent to all residents.
PURPOSE: The purpose of this Board item is to inform the City Commission that a Consumer
Confidence Report will again be sent to all Residents which is an Annual Report on the
Quality of their Drinking Water
CONSIDERA TIONS:
The 1996 Safe Drinking Water Act Amendments require that, beginning in October
1999, all community water systems provide customers with an annual report on the quality of
their drinking water. It is called the Consumer Confidence Report or CCR. The report format
and content are mandated by the local DEP office. In 2004, we did not include our chlorine
residual report in the disinfection bi-product table. This resulted in a violation. This year the
average residual and range has been included.
In addition, this year we are required to include the notice of the groundwater
contamination investigation by FDEP that has been ongoing since first reported in 2001. The
two primary sources of contamination are the Dearborn electronics site on 17-92 north of
Shepard Road and multiple areas on Seminola Boulevard in Casselberry west of Murphy Road.
We continue to sample multiple times per year at each well at WTP #2 (Sheoah Boulevard) and
WTP#3 (Bahama Road).
All results have been less than (2) two parts per billion of the contaminant - cis-1,2-
Dichloroethylene. The maximum contaminant level (MCL) for cis-l,2-Dichloroethylene is 70
parts per billion. The action level is 35 parts per billion. When contaminants are detected at
the action level, DEP requires a plan of action be submitted to address removal of the
contaminants when the MCL is reached. The most common method of removal is air stripping.
Informational Agenda Item 503
May 22, 2006
Page 2
The additional explanation requested by the Commission in the notice has been
incorporated into this report.
This is the sixth year that the report will be provided to utility customers. A copy of the
CCR is attached. The report will be sent out in June.
ATTACHMENTS:
1. Consumer Confidence Report
COMMISSION ACTION:
None required.
2005 Annual Drinking Water Report
The City of Winter Springs
East System I.D. 3591394 - 851 Northern Way WTP #1
West System I.D. 3590879 - 700 Sheoah Blvd. WTP- #2 &
110 W. Bahama Rd. WTP- #3
We're very pleased to provide you with this year's Annual Water Quality Report. We want to
keep you informed about the water quality and services we have delivered to you over the past year.
Our goal has always been, to provide to you a safe and dependable supply of drinking water. The
Tuscawilla and Oak Forest areas are generally served by the East system with the remainder of the
City served by the West system although the systems are interconnected.
Our East facility delivers over 1 billion gallons of treated water annually. A total of three (3)
production wells at this facility pump an average of2.740 million gallons daily to meet the residential,
commercial and irrigation needs. The fourth production well for this facility will be completed in
Spring of 2006. Our West facilities deliver over 430 million gallons of treated water annually from
both plants. A total of four (4) production wells pump an average of 1.294 million gallons daily to
meet the residential, commercial and irrigation needs. These wells are located within close proximity
to the plants and have an average depth of 350 feet, tapping into the Floridan Aquifer. The Department
of Environmental Protection has performed a Source Water Assessment in 2004 for our East and West
facilities and found potential contaminate from commercial petroleum tanks within the vicinity of our
well field. Although the susceptibility level is moderate we are closely monitoring for any changes.
The assessment results are available on the FDEP website at www.dep.state.fl.us/swapp
At all of the Winter Springs treatment plants, cascading aeration trays are used to strip the
water of Hydrogen Sulfide. The water is then disinfected by Chlorine gas or Sodium Hypochlorite
before being pumped into the distribution system.
If you have any questions about this report or concerning your water utility, please contact the
water treatment facility at 327-8992 from 8:00 am to 4:30 P.M. Monday-Friday. We want our valued
customers to be informed about their water utility. If you want to learn more, please attend any of our
regularly scheduled commission meetings. They are held the second and fourth Monday of every
month at 6:30 P.M. at City Hall.
The City of Winter Springs routinely monitors for contaminants in your drinking water
according to Federal and State laws. This table shows the results of our most recent monitoring period
from January 1st to December 31st 2005. The state allows us to monitor for some contaminants less
than once a year because the concentration ofthese contaminants does not change frequently. Some of
our data, though representative, are more than one year old. All water analyses are too most recent
sampling in accordance with the Safe Drinking Water Act. All drinking water, including bottled water,
may reasonably be expected to contain at least small amounts of some contaminants. The presence of
contaminants does not necessarily indicate that the water poses a health risk. More information about
contaminants and potential heaJth effects can be obtained by calling the Environmental Protection
Agency's Safe Drinking Water Hotline at 1-800-426-4791.
In the following tables you will find many terms and abbreviations you might not be familiar with.
To help you better understand these terms we've provided the following definitions:
Not Applicable (NI A) - does not apply
Non-Detects (NO) -laboratory analysis indicates that the constituent is not present.
Parts per million (ppm) or Milligrams per liter (mgll) - one part per million corresponds to one minute in two years or a
single penny in $10,000.
Parts per billion (ppb) or Micrograms per liter (ugll) - one part per billion corresponds to one minute in 2,000 years, or a
single penny in $10,000,000.
Action Level (AL) - the concentration of a contaminant which, if exceeded, triggers treatment or other requirements which
a water system must follow.
Picocuries per liter (pCi/L) - picocuries per liter is a measure of the radioactivity in water.
Maximum Contaminant Level (MCL) - The "Maximum Allowed" is the highest level of a contaminant that is allowed in
drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Maximum Contaminant Level Goal (MCLG) - The "Goal" is the level of a contaminant in drinking water below which
there is no known or expected risk to health. MCLGs allow for a margin of safety.
MCLs are set at very stringent levels. To understand the possible health effects described for many
regulated constituents, a person would have to drink 2 liters of water every day at the MCL level for a
lifetime to have a one-in-a-million chance of having the described health effect.
Some people may be more vulnerable to contaminants in drinking water than the general population.
Immuno-compromised persons such as persons with cancer undergoing chemotherapy, persons who
have undergone organ transplants, people with HIV/AIDS or other immune system disorders, some
elderly, and infants can be particularly at risk from infections. These people should seek advice about
drinking water from their health care providers. EP A/CDC guidelines on appropriate means to lessen
the risk of infection by cryptosporidium and other microbiological contaminants are available from the
Safe Drinking Water Hotline (800-426-4791).
In our continuing efforts to maintain a safe and dependable water supply it may be necessary to make
improvements in your water system. The costs of these improvements may be reflected in the rate
structure. Rate adjustments may be necessary in order to address these improvements.
Please call our office if you have questions.
We at the City of Winter Springs work around the clock to provide top quality water to every tap. We
ask that all our customers help us protect our water sources, which are the heart of our community, our
way oflife and our children's future.
The sources of drinking water (both tap water and bottled water) include rivers, lakes, streams, ponds,
reservoirs, springs, and wells. As water travels over the surface of the land or through the ground, it
dissolves naturally-occurring minerals and, in some cases, radioactive material, and can pick up
substances resulting from the presence of animals or from human activity. Contaminants that may be
present in source water include:
(A) Microbial contaminants, such as viruses and bacteria, which may come from sewage treatment
plants, septic systems, agricultural livestock operations, and wildlife.
(B) Inorganic contaminants, such as salts and metals, which can be naturally-occurring or result
from urban storm water runoff, industrial or domestic wastewater discharges, oil and gas
production, mining, or farming.
(C) Pesticides and herbicides, which may come from a variety of sources such as agriculture, urban
storm water runoff, and residential uses.
(D) Organic chemical contaminants, including synthetic and volatile organic chemicals, which are
by-products of industrial processes and petroleum production, and can, also, come from gas
stations, urban storm water runoff, and septic systems.
(E) Radioactive contaminants, which can be naturally occurring or be the result of oil and gas
production and mining activities.
In order to ensure that tap water is safe to drink, EP A prescribes regulations that limit the amount of
certain contaminants in water provided by public water systems. FDA regulations establish limits for
contaminants in bottled water that must provide the same protection for public health.
In 2004 we did not include our chlorine residual report in the disinfection bi-product table. This
resulted in a violation. This year the avera2e residual and ran2e has been included.
Drinking water, including bottled water, may reasonably be expected to contain at least small amounts
of some contaminants. The presence of contaminants does not necessarily indicate that the water poses
a health risk. More information about contaminants and potential health effects can be obtained by
calling the Environmental Protection Agency's Safe Drinking Water Hotline at 1-800-426-4791.
3591394 Winter Springs East
TEST RESULT TABLE
* * Results in the Level Detected column for radiological contaminants, inorganic contaminants, synthetic organic contaminants including
pesticides and herbicides, and volatile organic contaminants are the highest average at any of the sampling points or the highest detected
level at any sampling point, depending on the sampling frequency.
Contaminant and Unit Date of MCL/AL Level Range MCLG MCL Likely Source of
of Measurement sample Violation Detected Contamination
analysis YIN
Bacteriological Contaminants
Total Coliform 1/05-12/05 N 0 o out of 0 > 5% month Naturally present in the
240 environment
Radiological Contaminants
Gross Alpha (pCi/l) 6/05 N 3.0 N/A 0 15 Erosion of natural
deposits
Inorganic Contaminants
Contaminant and Unit Date of MCL/AL Level Range MCLG MCL Likely Source of
of Measurement sample Violation Detected Contamination
analysis YIN
Barium (ppm) 6/05 N .0150 N 2 2 Discharge from drilling
waste; Erosion of natural
deposits.
Chromium (ppb) 6/05 N 0.008 N 100 100 Discharge from steel and
pulp mills; Erosion of
natural deposits.
Sodium (ppm) 6/05 N 23.8 N/A N/A 160 Salt water intrusion,
leaching from soil
Nickel (ppm) 6/05 N .002 N/A N/A 0.1 Corrosion of household
plumbing systems,
erosion of natural
deposits
Selenium (ppm) 6/05 N .004 N/A 50 50 Selenium is an
essential nutrient.
However, some people
who drink water
containing selenium in
excess of the MCL
over many years could
experience hair or
fingernail losses,
numbness in fingers or
toes, or problems with
their circulation
Lead and Copper Home Sampling
Lead (tap water) (Ppb) 2005 N 3.5 o sampling 0 AL-15 Corrosion of household
(90th site plumbing systems,
percentile) exceeded erosion of natural
AL deposits
Copper (tap water) 2005 N .686 o sampling 1.3 AL= 1.3 Corrosion of household
(ppm) (90th site plumbing systems;
percentile) exceeded erosion of natural
AL deposits; leaching from
wood oreservatives
Volatile Organic Contaminants
DicWoromethane 6/05 N 2.41 N/A 0 5.0 Dichloromethane. Some
(ppb) people who drink water
containing dichloromethane
in excess of the MCL over
many years could have liver
problems and may have an
increased risk of getting
cancer.
TTHMs and Stage 1 Disinfectant/Disinfection By-Product (D/DBP) Parameters
Choose one bulleted paragraph below according to the Section 7 instructions, depending on when monitoring began:
. For the following parameters monitored under Stage 1 D/DBP regulations, the level detected is the highest annual average of the
quarterly averages: Bromate, CWoramines, Chlorine, Haloacetic Acids, and/or TfHM (MCL 80 ppb). Range of Results is the range
of results (lowest to highest) at the individual sampling sites.
. For the following parameters monitored under Stage 1 D/DBP regulations, the level detected is the annual average of the quarterly
averages: Bromate, CWoramines, CWorine, Haloacetic Acids, and/or TTHM (MCL 80 ppb). Range of Results is the range of results
(lowest to highest) at the individual sampling sites.
Contaminant Dates of MCL Level Range MCLG or MCL or Likely Source of Contamination
and Unit of sampling Violation of
Measurement (mo.lyr. ) YIN Detected Results MRDLG MRDL
78. Chlorine 2005 N 1.4 0.2-2.9 MRDLG = MRDL=4.0 Water additive used to control microbes
(ppm) 4
79. Haloacetic 44.0 12.7-
Acids (five) 2005 N (annual 44.0 NA MCL = 60 By-product of drinking water disinfection
fU A H, (ppb) averae:e)
80. TTHM 69.7
[Total 2005 N (annual 31.66- NA MCL=80 By-product of drinking water disinfection
trihalometha 69.7
nesl (ppb) average
3590879 Winter Springs West
TEST RESULT TABLE
** Results in the Level Detected column for radiological contaminants, inorganic contaminants, synthetic organic contaminants including pesticides
and herbicides, and volatile organic contaminants are the highest average at any of the sampling points or the highest detected level at any sampling
point, depending on the sampling frequency.
Contaminant and Unit of Date of MCL/AL Level Range MCLG MCL Likely Source of
Measurement sample Violation Detected Contamination
analysis Y/N
Bacteriological Contaminants
Total Coliform 1/05-12/05 N 0 o out of 0 > 5% month Naturally present
240 in the environment
Radiological Contaminants
Gross Alpha (PCiIl) 6/05 N 1.7 1.0-1.7 0 15 Erosion of natural
deposits
Inorganic Contaminants
Barium (ppm) 6/05 N .012 .010-.0120 2 2 Discharge from
drilling waste;
Erosion of natural
deposits.
Chromium (Ppb) 6/05 N 8.00 5.00-8.00 100 100 Discharge from steel
and pulp mills;
Erosion of natural
deposits.
Sodium (ppm) 6/05 N 11.9 11.8-11.9 N/A 160 Salt water intrusion,
leaching from soil
Inorganic Contaminants (continue)
Selenium (ppm) 6/05 N .003 .002-.003 .05 .05 Selenium. Selenium is an
essential nutrient. However,
some people who drink water
containing selenium in excess of
the MCL over many years could
experience hair or fmgernail
losses, numbness in fingers or
toes, or problems with their
circulation.
Barium (ppm) 6/05 N .012 .01-.012 2 2 Discharge from drilling waste;
Erosion of natural deposits.
Sodium (ppm) 6/05 N 11.9 11.8-11.9 N/A 160 Salt water intrusion, leaching from
soil
VolatileOrganic
Contaminants
Dichloromethane 6/05 N 2.06 N/A 0 5.0 Dichloromethane. Some people
(ppb) who drink water containing
dichloromethane in excess of the
MCL over many years could
have liver problems and may
have an increased risk of getting
cancer.
Lead and Copper Home Sampling
Lead (tap water) (ppb) 2005 N .003 o site 0 AL=15 Corrosion of household
(90th exceeded plumbing systems,
percentile) AL erosion of natural
deposits
Copper (tap water) (ppm) 2005 N .800 o sampling 1.3 AL=1.3 Corrosion of household
(90th sites plumbing systems;
percentile) exceeded erosion of natural
AL deposits; leaching from
wood preservatives
TTHMs and Stage 1 Disinfectant/Disinfection By-Product (D/DBP) Parameters
Choose one bulleted paragraph below accirding to the Section 7 instructions, depending on when monitoring began:
. For the following parameters monitored under Stage 1 D/DBP regulations, the level detected is the highest annual average of the
quarterly averages: Bromate, Chloramines, Chlorine, Haloacetic Acids, and/or TTHM (MCL 80 ppb). Range of Results is the range
of results (lowest to highest) at the individual sampling sites.
. For the following parameters monitored under Stage 1 D/DBP regulations, the level detected is the annual average of the quarterly
averages: Bromate, Chloramines, Chlorine, Haloacetic Acids, and/or TTHM (MCL 80 ppb). Range of Results is the range of results
(lowest to highest) at the individual sampling sites.
Contaminant and Unit Dates of MCL Level Range MCLG MCL or
of Measurement sampling Violation Detected of or MRDL Likely Source of Contamination
(mo./yr. ) Y/N Results MRDLG
78. Chlorine (ppm) 2005 N 1.4 0.2-2.9 MRDLG MRDL = 4.0 Water additive used to control microbes
=4
79. Haloacetic Acids 44.0 12.7-
(five) (HAAS) (ppb) 2005 N (annual 44.0 NA MCL = 60 By-product of drinking water disinfection
average)
80. TTHM [Total 69.7 31.66-
trihalomethanes] (ppb) 2005 N (annual 69.7 NA MCL = 80 By-product of drinking water disinfection
average
HELPFUL WATER HINTS
LOWERING WATER BILL & CONSERVING WATER:
1. An average tub holds 50 gallons of water. Conserve water by only partially filling the tub.
2. Install water saving showerheads.
3. Only run dishwashers and washing machines with full loads.
4. Regularly check pipes, hoses, valves, and faucets for leaks
5. Add food coloring to the water in the tank. If color appears in bowl without flushing, there
is a leak. Fix or replace parts.
6. Longer grass means less evaporation. Let grass grow taller in hot, dry
weather.
7. Set irrigation timer for early morning, around 2 A.M. or 3 A.M. to help prevent evaporation
and help to increase your water pressure for household activities.
8. Install an irrigation rain gauge to prevent over watering.
9. Use a broom instead of a water hose to clear debris from patios, driveways, and sidewalks.
10. Do not allow garden hose's to run unattended.
Watering Restriction
Irrigation is prohibited between 10a.m. and 4p.m.
Even residential and commercial addresses can water their lawns Thursday and
Sundays
Odd residential and commercial addresses can water their lawns Wednesday and
Saturday
This includes all water sources including potable water, reclaimed water, surface water
and wells.
For more information on rules under the water restriction you can contact the City of
Winter Springs Water Treatment facility at 407-327-8992.