Loading...
HomeMy WebLinkAbout1985 09 24 Site Plan Review Board "~_.-..:' ~~___,_~'- ,,__~. l'.~, ~ ~-r-' ..~.- . \'.~. bill'. . P~~:o::.~.:c~. 500 W. FUlTON STREET POsT OFFICE BOX 117. SANFORD. FlORIO~- TEl305322-18.1 TEl3051J1-5717 it f t ! ~ .1/ l~:' ~r September 24, 1985 Mr. Peter Cowell City of Winter Springs 1126 East S.R. 434 Winter Springs, FL 32708 RE: John M. Hall Company Site Plan CPH Job No. W0402.00 .~ t ~~ ~' i Dear Mr. Cowell: In accordance with your request, we have reviewed the site plan for John M. Hall Company. We have also reviewed the attached drainage calculations for this site. The following items need to be resolved prior to final approval of this site for construction: 1. The datum utilized for the site survey is not a U.S.G.S. datum as contours of 100 and above are shown which do not exist on this site. Natural datum in accordance with the Land Development .Code which requires the use of the U.S.G.S. should be provided. 2. The site survey of the existing site conditions and contour lines do not corresp0nd to the existing contour lines as shown on the site plan. We need an explanation why these do not coincide. 3. No so11s report was attached, however, we did receive some information on a percolation test for the septic field which indicated a groundwater table of 37 inches below existing grade. We do not, however, know that this is the anticipated high groundwater table. Therefore, we are not certain that the underdrain system will work correctly and provide positive drainage away from the site. The underdrain system shown on the detail sheet does not quite provide the 2.0 feet of minimum cover as required by the DOT. The bottom elevation of the pond should be 101.1 to provide that 2.0 feet of cover, and not the 100.8 as shown on the plans. 4. The driveway within the right-of-way must meet the Land Development Code which requires l-1/2-inches of Type 1 asphaltic cpncrete and not the l-inch shown on Detail Sheet No.3. '. ,-- ..........-- ,\. Coni . ~ort.r and. Ho...... cg ~ ENGINEERS, 1tC. 100 W. FlA. TON STREET POST OFFICE BOX 117. SANFORD. FLORI)A 32771 TEL305322-6141 TEL30S131-S717 " fo j :1.' "'.' 't I. i I Y f? i~ 9/24i85 Mr. Peter Cowell City of Winter Springs Page 2 5. Please provide a minimum of l8-inches of clean sand above the filter fabric wrapped around the underdrain as shown on the detail on Sheet 3. , f ~, ~~ f t 6. Some reinforcement should be replaced in the concrete slab over the top of the fuel storage area. 7. We request the eventual outfall of the drainage system from this project down the old Sanford/Oviedo Road. What is the ending point of this stormwater? Please advise when these items have been corrected and ready for our review. Si ncerely, PORTER & HOLMES-ENGINEERS, INC. / TMZ:pat .; ., t.1.- '1-' . ," ~. Ie f ,1" '.