Loading...
HomeMy WebLinkAbout2025 04 24 Public Hearing 401 - Chick-Fil-A Building Elevations AEXTERIOR FINISHES PREFINISHED METAL COPING COLOR: MIDNIGHT BRONZE BRICK VENEER COLOR: RED SIZE: MODULAR EXTERIOR PAINT COLOR: DARK BRONZE FINISH: SEMI-GLOSS STOREFRONT COLOR: DARK BRONZE BR-A EC-1 PT-113 ST-1 B/ CANOPY 9'-8" WATER TABLE 3'-0" T/ LOW PLATE 21'-10" T/ SLAB 0" T/ SOLDIER 16'-8" T/ MID PLATE 23'-2" T/ HIGH PLATE 25'-2" T/ LOW PLATE 21'-10" WATER TABLE 3'-0" T/ SLAB 0" T/ SOLDIER 16'-8" T/ SOLDIER +/- 11'-3" T/ MID PLATE 23'-2" B/ CANOPY 9'-8" WATER TABLE 3'-0" T/ LOW PLATE 21'-10" T/ SLAB 0" C5-AC4-B T/ SOLDIER 13'-0" C4-GC4-G T/ MID PLATE 23'-2" T/ SOLDIER 16'-8" T/ SOLDIER 18'-0" T/ HIGH PLATE 25'-2" T/ SOLDIER 16'-8" T/ MID PLATE 23'-2" WATER TABLE 3'-0" B/ CANOPY 9'-8" T/ SLAB 0" C4-BC4-B T/ HIGH PLATE 25'-2" DISCLAIMER: THE PANORAMA IS FOR THE PROTOTYPICAL TEMPLATE AND MAY NOT REPRESENT SITE SPECIFIC CHANGES. Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. CONSULTANT PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY REVISION SCHEDULE A 1234 B C D E A B C D E 1234 CH I C K -FI L -A BUILDING TYPE / SIZE: RELEASE: # 6/ 1 4 / 2 0 2 4 2 : 0 4 : 3 1 P M Au t o d e s k D o c s : / / F L _ 0 5 8 1 4 _ W i n t e r S p r i n g s _ 2 0 2 4 . 5 _ F S R / 05 8 1 4 _ W i n t e r S p r i n g s _ A R C . r v t X-900 DESIGN OVERVIEW - BRICK SCHEMATIC DESIGN 05/27/24 SC WI N T E R S P R I N G S 05814 E S R 4 3 4 & M I C H A E L B L A K E B L V D . WI N T E R S P R I N G S , F L 3 2 7 0 8 XX -LE -05 8 1 4 -X-90 0 -DE S I G N O V E R V I E W - BR I C K 2024223.17 24.05 P14 LE BS FSR NOT FOR REGULATORY APPROVAL, BIDDING, OR CONSTRUCTION PERSPECTIVE VIEW PERSPECTIVE VIEW PERSPECTIVE VIEW PERSPECTIVE VIEW ATTACHED CANOPY SCHEDULE Mark Description Count Overall Width Overall Depth Tie Back Mounting (Offset From Top) Integral Lighting C4-B Exterior Canopy 2 5'-4" 4'-0" 2'-4" Yes C4-G Exterior Canopy 1 7'-4" 4'-0" 2'-4" Yes C5-A Exterior Canopy 1 12'-0" 5'-0" 2'-4" Yes Grand total 4 EXTERIOR ELEVATION EXTERIOR ELEVATION EXTERIOR ELEVATION EXTERIOR ELEVATION Seat Count - Interior: Seat Count - Exterior: Number of Registers: LEED Rating Landscaping Type Water Filtration Type: Playground Kitchen Type: Exterior Finish Type: Wall Framing Type: *Acceptable Values: TOWER BRICK, TOWER STUCCO, TOWER BOARD, WRAP BRICK, WRAP STUCCO PROJECT DATA *Acceptable Values: WOOD STUD, WOOD STUD - PREFAB, METAL STUD, METAL STUD - PREFAB, STEEL FRAME, CMU, VOLUMETRIC MODULAR *Acceptable Values: CENTERLINE 2.0, CENTERLINE 3.0 *Acceptable Values: STANDARD *Acceptable Values: YES, NO *Acceptable Values: TYPE A, TYPE A+B, TYPE A+C, TYPE A+B+C, ETC *Acceptable Values: NOT CERTIFIED, CERTIFIED, SILVER, GOLD, PLATINUM Industrialized Construction: *Acceptable Values: YES, NO Number of Parking Spaces: *Acceptable Values: (Digits) Number of Accessible Parking Spaces: *Acceptable Values: (Digits) Cross Parking: *Acceptable Values: YES, NO Canopy Type - Order Point: Canopy Type - Meal Delivery: Drive Thru Stack Count: *Acceptable Values: (Digits) Drive Thru Dedicated Bypass Lane: *Acceptable Values: YES, NO Drive Thru Number of Approach Lanes: *Acceptable Values: (Digits) Drive Thru Number of Ordering Lanes: *Acceptable Values: (Digits) Drive Thru Number of Fulfillment Lanes: *Acceptable Values: (Digits) Number of Walk-up Windows: *Acceptable Values: (Digits) Building Area Square Footage: DESIGN APPROVAL SUP SD DD CD NOT APPROVED - REVISE AND RESUBMIT APPROVED AS NOTED - REVISE AND RESUBMIT APPROVED FOR DESIGN INTENT INITIAL:DATE: Drive Thru Opening: *Acceptable Values: DOOR, WINDOW, NONE Menu Board - Interior - Count: Menu Board - Interior - Type: Menu Board - Walk-up - Type: Menu Board - Walk-up: Menu Board - Walk-up - Count: Menu Board - Interior: Menu Board - Order Point: Menu Board - Order Point - Count: Menu Board - Order Point - Type: *Acceptable Values: YES, NO *Acceptable Values: (Digits) *Acceptable Values: (Digits) *Acceptable Values: (Digits) *Acceptable Values: DIGITAL, STATIC, OTHER *Acceptable Values: (Digits) *Acceptable Values: YES, NO *Acceptable Values: DOUBLE, SINGLE *Acceptable Values: (Digits) *Acceptable Values: DOUBLE, SINGLE *Acceptable Values: (Digits) *Acceptable Values: DIGITAL, STATIC, OTHER *Acceptable Values: YES, NO *Acceptable Values: (Digits) *Acceptable Values: DIGITAL, STATIC, OTHER Prototype Edition: *Acceptable Values: LS, LSR, LE, SE, DR, DS Planned Classification: *Acceptable Values: BASE MODIFIED-LOW MODIFIED-MEDIUM MODIFIED-HIGH CUSTOM-LOW CUSTOM-HIGH PROJECT NOTES *Record any personal notes with text, views, or schedules Canopy Structure: *Acceptable Values: STEEL, CONCRETE NOT CERTIFIED STANDARD TYPE A SMALL CENTERLINE 3.0 TOWER BRICK WOOD STUD NO 70 3 NO # NO 2 2 2 0 DOOR 5157 66 12 DOUBLE DOUBLE 3 YES 4 DIGTAL NO 0 N/A YES 4 DIGITAL LE BASE STEEL CANOPY AREA 1437 SF BUILDING FOOTPRINT INSIDE FACE OF FINISH 5157 SF NO.DATE DESCRIPTION