Loading...
HomeMy WebLinkAboutDish Wireless Construction Documents - 2021 06 23.pdfmw wireless. DISH WIRELESS L.L.C. SITE ID: ORMC000169A DISH WIRELESS L.L.C. SITE ADDRESS; 1126 E. SR 434 WINTER SPRINGS9 FL 32708 FLORIDA -CODE COMPLIANCE AI.L WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOLL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE LON BUILDING 2020 FLORIDA BUILDING CODE 7TH EDITION/2018 IBC MECHANICAL 2020 FLORIDA BUILDING CODE 7TH EDITION/2015 IMC ELECTRICAL 2020 FLORIDA BUILDING CODE 7TH EDITION/2014 NEC SHEET INDEX SHEET N0. SHEET TITLE T-1 TITLE SHEET A-1 OVERALL AND ENLARGED SITE PLAN A-2 ELEVATION, ANTENNA LAYOUT AND SCHEDULE A-3 EQUIPMENT PLATFORM AND H—FRAME DETAILS A-4 EQUIPMENT DETAILS A-5 EQUIPMENT DETAILS A-6 EQUIPMENT DETAILS E-1 ELECTRICAL/FIBER ROUTE PLAN AND NOTES E-2 ELECTRICAL DETAILS E-3 ELECTRICAL ONE —LINE & PANEL SCHEDULE G-1 GROUNDING PLANS AND NOTES G-2 GROUNDING DETAILS G-3 GROUNDING DETAILS RF-1 RF CABLE COLOR CODES RF-2 RF PLUMBING DIAGRAM GN-1 LEGEND AND ABBREVIATIONS GN-2 GENERAL NOTES GN-3 GENERAL NOTES CN-4 GENERAL NOTES EE SCOPE OF WORK THIS IS NOT AN ALL INCLUSIVE UST. CONTRACTOR SHALL UTILIZE SPECIFIED EQUIPMENT PART OR ENGINEER APPROVED EQUIVALENT, CONTRACTOR SHALL VERIFY ALL NEEDED EQUIPMENT TO PROVIDE A FUNCTIONAL SITE. THE PROJECT GENERALLY CONSISTS OF THE FOLLOWING: TOWER SCOPE OF WORK: • INSTALL (3) PROPOSED PANEL ANTENNAS (1 PER SECTOR) • INSTALL (1) PROPOSED ANTENNA PLATFORM MOUNT • INSTALL PROPOSED JUMPERS INSTALL (8) PROPOSED RRHs (2 PER SECTOR) • INSTALL (1) PROPOSED OVER VOLTAGE PROTECTION DEVICE (OVP) • INSTALL (1) PROPOSED HYBRID CABLE GROUND SCOPE OF WORK: • EXISTING ABANDONED PLATFORM TO BE UTIUIZEO • INSTALL (1) PROPOSED ICE BRIDGE • INSTALL (1) PROPOSED PPC CABINET • INSTALL (1) PROPOSED EQUIPMENT CABINET • INSTALL (1) PROPOSED POWER CONDUIT • INSTALL (1) PROPOSED TELCO CONDUIT INSTALL (1) PROPOSED TELCO—FIBER BOX • INSTALL (1) PROPOSED GPS UNIT • INSTALL (1) PROPOSED FIBER NIO (IF REQUIRED) • DISH WIRELESS L.L.C. TO UTILIZE POSITION 'C' ON EXISTING METER BANK • INSTALL (1) PROPOSED FUSIBLE SAFETY SWITCH UNDERGROUND SERVICE ALERT -SUNSHINE 811 UTILITY NOTIFICATION CENTER OF FLORIDA (800)432-4770 WWW.SUNSHINE811.COM GAL 2 NORIOG DAYS UTILITY NOTFICATION PRIOR TO CONSTRUCTION GENERAL NOTES THE FACILITI' IS UNMANNED AND NOT FOR HUMAN HABITATION. A TECHNICLW WILL VISIT THE SffE AS REQUIRED FOR ROUTINE MAINTETUNCE. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE. NO SANITARY SEWER SERVICE, POTABLE WATER, OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SICNAGE IS PROPOSED. 11"x17" PLOT WILL BE HALF SCALE UNLESS OTHERWISE NOTED CONTRACTOR SHAM VERIFY ALL PLANS, IXISTINC DIMENSIONS, AND CONDITIONS ON THE JOB SRE, AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK. SITE INFORMATION PROJECT DIRECTORY PROPERTY OWNER: CRY OF WINTER SPRINGS FL APPLICANT: DISH WIRELESS LLC. ADDRESS: 1126 E STATE RD 434 5701 SOUTH SANTA FIE DRIVE WINTER SPRINGS, FL 32708 LITTLETON, 00 80120 TOWER TYPE MONOPOLE TOWER OWNER: CROWN CASTLE USA, INC. 2000 CORPORATE DRIVE TOWER CO SITE ID: 825280 CANONSBURG, PA 15317 877,486,9377 TOWER APP NUMBER: 553735 SITE DESIGNER: JACOBS TELECOMMUNICATIONS, INC COUNTY: SEMINOLE 5449 BELLS FT]tR1' ROAD ACWORTH, GA 30102 LATITUDE HAD 83): 28. 42' 9.45' N 470.785.4050 28m702625 N LONGITUDE (HAD 83): 81. 15' 59,22' W SITE ACQUISITION: ANTONIOARRGYO—MONROY 81.286450 W ANTONKI.ARROYO—MONROY ZONING JURISDICTION: CITY OF WINTER SPRINGS OCROWNCASTLE.COM CONSTRUCTION MANAGER: FRANK MENTUCK ZONING DISTRICT: UNKNOWN FRANCIS.MENTLICKODISH.CI PARCEL NUMBER: 28-20-30-5AR—OB00-027A I RF ENGINEER: YOCENDHAR SURPANENI YOGENDHAR.SURPANENI OCCUPANCY GROUP: U ODISH.COM CONSTRUCTION TYPE V—B TELEPHONE COMPANY: UNIT1 FIBER DIRECTIONS TAKE I-4 E TO EXIT 94 FL-434 TURN RIGHT ONTO FL-434 fOR 8 MILES TOWER WILL BE ON THE LEFT BEHIND CITY HALL 1126 N STATE RD 434 VICINITY MAP 1.'IN:': AY PARK $Piing ' Hammock PreDcrvc Wimer son9� (q H!qh Scllonl r rinler Springs SITE LOCATION VJ!Bge Co OP(; I� • No OF .sh 5701 SOUTH SAWA FE DRIVE UTTLETON, CO 80120 Jacobs. Challenging today. Reinventing tomorrow. Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD AC WORTH, GA 30102 Stephen C. P'� C. Rdgs Dale, 2031.0623 Rid a 9 142645-(HW * No. 91030 �:• STATE OF °FSSNONALE�G`� m Nnn10 TNIS ITE1.1 RAS BEEN ELECTRONICALLY SIGHED NID SEALED BY STEPIIEN C. RIDGE USRIG A DIGITAL SIG'lATURE N!D DATE PNIREO COPIES OF THIS DOCUMENT ARE NOT CON SIDERFD SIG!IED AND SEALED AND THE SIGNATURE 41UST BE \VERIF)ED ON NN ELECTRONIC COPIES R IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A DCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT, DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KIRK REDS REV �: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 00/2D/T02I ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER EUCC0309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE TITLE SHEET SHEET NUMBER T-1 v EXISTING 56 SO FT PAD IN A (12'X20') AREA BELOW PLATFORM NOTES 1. 2. CONTRACTOR SHALL FIELD VERIFY ANTENNAS AND MOUNTS OMITTED ALL FOR DIMENSIONS. CLARITY. 43'-11" (COMPOUND AREA) 1'-3" 9'-10" 11'-0•' 31 I7" 18'-3" EXISTING (4'X4') I EXISTING 34.5 AREA SO FT ELEV. — — — � PLATFORM X ! x x I x x x x EXISTING . (4'X6') v x GEN PAD/ // + + AREA iI EXISTING (111_9,. X 16'-2") PAD INA M (15' X 20') AREA F I � r n ,O EXISTING MONOPOLE — a TOWER EXISTING x ♦`� EXISTING ICE BRIDGE TYP cl ♦I I \ (5'-0" x 11'-0") ( ) I GEN PAD/AREA I � {pqy 1 O EXISTING L J St 1 (4'X4') PAD I1 SEE ENLARGED A SITE PLAN a EXISTING 1 II\ EXISTINGSHELTER EQUIPMENT i 0 N (161x22') �I�' iy4 (12 -o" x 20 -o) x n PLATFORM ♦ III ' 1 1; \�\ I NNgo EXISTING 7'-6" � � EXISRNG EMPTY UTILITY H—FRAME EXISTING 9'-8" METER SOCKET 'C' TO UTILITY H—FRAME BE UTILIZED BY DISH WIRELESS, LLC. 9'-4" 13'-2" 4'-4" Ix PROPOSED DISH WIRELESS} LLC. 12' WIDE ICE BRIDGE x im 1 I 1 1 1 x 1 1 1 1 1 I 1 1 1 1 1 1 1 i I _ LEASE AREA 1 1 1 1 1 1 1 1 -1IIr�L 1 1 ----- - -- rJI1----i--- ENLARGED SITE PLAN NOTES 1, CONTRACTOR SHALL FIELD VERIFY ALL DILIENSXNIS. 2. CONTRACTOR SHANJ_ MAINTAIN! A 10'-0' MINIMUM SEPARATKIN BETWEEN THE PROPOSED DIPS UNIT, TRANSMITTING ANTENNAS AND EXISTING DIPS UNITS. 3. ANTENNAS AND MOUNTS OMITTED FOR CLARITY. EQUIPMENT xJT (SHEET A-3) 3/8•=I,—O' OVERALL SITE PLAN � �A NO SCALE r .,sh ,. 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 Jacob& Challenging today. Reinventing tomorrow. Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 co ouuunu„ lfIll N G E N S Ro /i No. 91030 STATE OF ' OFFSS� 0RID•FP'ssel, `�` nnnnunaa TFIS ITEIA M/5 BEEN ELECTROI,ICALLY SIGNED NO SENF-D BV STEPN01 C. RIDGE USING A DIG RAL SIGiUTURE NADATE. PPoNTED COPIES OF MS DCCUTAENT NiE LOT CONSIDERED SICNED MID SENED MID THE SB:NARIRE MUST BE \'ER IFIED 0..%AIN ELECTROAIC COPIES IT IS A NOUTION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KIRK RFDS REV (�: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A OS/27/10QI 6SUED FOR 0ONST UCI10N AdcE PROJECT NUMBER EUCCO309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E, SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE OVERALL AND ENLARGED SITE PLAN SHEET NUMBER A-1 1 I 1 1 1 x 1 1 1 1 1 I 1 1 1 1 1 1 1 i I _ LEASE AREA 1 1 1 1 1 1 1 1 -1IIr�L 1 1 ----- - -- rJI1----i--- ENLARGED SITE PLAN NOTES 1, CONTRACTOR SHALL FIELD VERIFY ALL DILIENSXNIS. 2. CONTRACTOR SHANJ_ MAINTAIN! A 10'-0' MINIMUM SEPARATKIN BETWEEN THE PROPOSED DIPS UNIT, TRANSMITTING ANTENNAS AND EXISTING DIPS UNITS. 3. ANTENNAS AND MOUNTS OMITTED FOR CLARITY. EQUIPMENT xJT (SHEET A-3) 3/8•=I,—O' OVERALL SITE PLAN � �A NO SCALE r .,sh ,. 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 Jacob& Challenging today. Reinventing tomorrow. Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 co ouuunu„ lfIll N G E N S Ro /i No. 91030 STATE OF ' OFFSS� 0RID•FP'ssel, `�` nnnnunaa TFIS ITEIA M/5 BEEN ELECTROI,ICALLY SIGNED NO SENF-D BV STEPN01 C. RIDGE USING A DIG RAL SIGiUTURE NADATE. PPoNTED COPIES OF MS DCCUTAENT NiE LOT CONSIDERED SICNED MID SENED MID THE SB:NARIRE MUST BE \'ER IFIED 0..%AIN ELECTROAIC COPIES IT IS A NOUTION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KIRK RFDS REV (�: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A OS/27/10QI 6SUED FOR 0ONST UCI10N AdcE PROJECT NUMBER EUCCO309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E, SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE OVERALL AND ENLARGED SITE PLAN SHEET NUMBER A-1 • • a 1 a- _ T • a . . 3. EXISTING EQUIPMENT AND FENCE OMITTED FOR CLARITY. 4. T.a.:. • n a. � • -� T • � a• ]- • •jm*j:pmmlkII vroill4liellef4l -• a •i' • PROPOSED WEST ELEVATION -.-. 01 1., -3 ].K a ;- .^ •,a1 1 divi lwlo ::mLl MOUNT PER SECTOR1 T( EXISTING LIGHTNING ROD � TOP EL. 0 173'-0" AGL PROPOSED DISH WI'. L.LC, RRH (TV EXISTING MONOPOLE Alk SECTOR, T( TOP EL, 0 165'-0" AGL EXISTING PANEL ANTENNAS RAD CENTER 0 163'-0" AGL EXISTING PANEL ANTENNAS RAD CENTER 0 157'-0" AGL EXISTING PANEL ANTENNAS O RAD CENTER 0 150'-0" AGL EXISTING ANTENNA MOUNT % RAD CENTER 0 144'-0" AGL EXISTING PANEL ANTENNAS RAD CENTER 0 134'-0" AGL EXISTING PANEL ANTENNAS RAD CENTER 0 120'-0" AGL tea• ] � a � ED as11 YnRELESS D CJ�BLE ROUTED UP JQN -•• • dal � a• . a a.� • a . a -111 r a DISH .LC. OVP ANTENNA TRANSMISSION CABLE SECTOR POSRION EXISTING OR MANUFACTURER —MODEL RAD 1ECHNOLAGY SIZE (HzW) AZIMUTH FEED LINE TYPE PROPOSED NUMBER CENTER AND LENGTH ALPHA Al PROPOSED JMA — MX08FRO665-20 5G 72.8" x 20.00 0' 1121-0' (1) HKR1—CAPACITY BETA 81 PROPOSED JMA — MX0BFRO665-20 511 72,8' X 20,0' 120' 112'-0* HYBRID CABLE (1500 LONG) GAMMA Cl PROPOSED JMA — MXO8FR0665-20 513 72,8' X 2090' 240' 112'4,Md0' DETAILS, u• /la ®�■,� 1:1 1 I "" • 1 a ANGE UE UIPMENT 1 •APPROVED , ANTENNAAVAILABIUTYe © ALL EQUIPMENT CHANGES AND REMAIN IN COMPLIANCE WITH THE PROPOSED DESIGN AND I:r•T��ra r wr ..sh wksi m 5701 SOUTH SANTA FE DRIVE uTTLETON, CO 80120 vacoba Challenging today. Reinventing tomorrow. Jacobs Telecommun(catlmEs, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 eN yN *qcN NsR/p�� Ode do _ A = STATE Of •:��`F dqlqoe FSS/pNAIdeep E1G`d to INININ 1t951TE1.1 MAS BEEN ELECTRONICALLY SIGNED AND SEALED DY S1E%IE4 C. RIDGE USING A DIGITAL SIGNATURE AIlO DATE PRIfRED COMES OF PITS DOCUTAENT ARE NOT COIlSiDEREO SIGNED AND SEALED AND PIE SIGNATURE LW ST BE \ERIFIED ON ANY ELECTRONIC COPIES R IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: 1APPROVED BY: CRO WBP KRK RFDS REV #: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 00/2J/14QI SSUFD FOR OONSTRUCDON A&E PROJECT NUMBER EUCC0309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE ELEVATION, ANTENNA LAYOUT AND SCHEDULE SHEET NUMBER A=2 •. -•,tea. ,.� •,a a.. KENWOOD T1701KT5-5S H—FRAME UNISTRUT/SUPPORT RAIL 5 MMONOWWWO WEIGHT/ VOLUME 173.8 LBS donuffiffinow [3Gi�aP i:9a6P(95A SUPPORT cuv r EQUIPMENT LEASE AREA 1'-0' 2' 2'' 0'1 1600020 I 2'-9• �--- �---1=owwwwNy ownwNffm ---- NO — _ —— WOW II 1) PROPOSED II DISH WIRELESS L.L.C. I I I) EQUIPMENT CABINET 'I) II I) I IN \ I � • •.y w iV No SCALE ( 3 I NOT USED [sit ..L� • .- a I a' 2011 MqA�:... ,. r U URAL ANALYSIS OF E)asTiNG asPLAVORM NOTINCLUDED OF WORK. CAPACITY OF SKALL BE CHECKED TO INSTALLATION OF o .•. a. EQUIPMENT NO SCALE 2 q h NOTES IEV"iliiY+i{�liff/ IFINISHED m GRADE:ED BARRIER i•l • 9 I a PROPOSED DISH 1 WIRELESS LLC° I ' I FIBER IND. IF I Q C 0 REQUIRED I "� U f nni I tRmRc% � m __ 0 0 PROPOSED DISH 'ra WIRELESS LLC. I JELCO;FIBER ENCLOSURE 0 MINT --�:v �,a* •SSZati 5 �r r .sh VVk*IWS. 5701 SOUTH SANTA FE DRIVE uTTLETON, CO 80120 Jacobs Challenging today. Reinventing tomorrow. Jacobs Telecomnn nicalions, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 pnll"nlny H6N Co �r''�.ICEHSf''•.f �'.. No, 91030 STATE OF :�tt iHi5liElA HAS ME14 ELECTRONICALLY SIGNED At ID SEALED BY STEM C. RIDGE US61G A DIGITAL SIGNATURE N!D DATE. GRIMED CO ES OF MS DOCUTAENT ARE NOT CONSIDERED SIGN-cO AND SEAL ED AND PRE SIG!IATURE \NST BE VERIFIED ON ANY ELECTRONIC COPIES R IS A VIOUTION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICEtISED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KRK RFDS REV #: TBD ENEWN CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 0!/2J/24QI ISSUED FOR CONSTRUCTIONA&E PROJECT NUMBER EUCCO309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E° SR 434 WINTER SPRINGS, FL 32708 mmmw SHEET TITLE EQUIPMENT PLATFORM AND H—FRAME DETAILS 01000 SHEET NUMBER A=3 ENERSYS HEX CABINET 2000005996 DIMENSIONS (HxWxD): —_ 73•00•020 WEIGHT EMPTY: 378 The HEATER 800W POWER SYSTEM 4101,46V AI.PHA/bOOA 3.b• DUl CALV SCH 40 flPE (SPACED 9'-0• MAx) ( ELM \ O 0 O 0 F`G;4 RAYCAP PPC RDIAC-2465-P-240-MTS ENCLOSURE DIMENSIONS (HxWxD): 390x22.855•x12.593 WEKWOO 80 Ibs OPERATING AC VOLTAGE 240/120 1 PHASE 3W+G O G O C o p' O 0 O O G II ��•i:l ZAYO 5RU CABINET LEFT SWING DOOR ("LIT" SITES) DIMENS06 (HxWxD)--- 3b.115•x29•x12.9• WEIGHT 85 LBS POWER INPUT 2OAr —48VDC I( 1 0 fT'1L SQUARE D FUSIBLE SAFETY SWITCH D224NRB ENCLOSURE DIM (HxWxD) 29.25•x19,00•x8.50' ENCLOSURE TYPE NEMA 3R RAINPROOF UL LISTED FILE E-2875 CHARLES CFIT-PF2020DSH1 FIBER TELCO ENCLOSURE ENCLOSURE DIMS (HxWxD) 20•x20•x9• ENCLOSURE WE10HT 20 Ibs MOUNTING WALL WMPU44CE TYPE 4 E84tff ro o Ear¢ iris ; > T MONSOON NETWORK INTERFACE UNIT DETAIL No smE 5 FIBER TELCO ENCLOSURE DETAIL NO SCALE 6 SUPPORT BRACKET A —A A —A (WB—L812-3) PROPOSED 3.5' DUI log 040 3• DIA SCH 40 PIPE I SCH 40 PIPE �I CALVANIZ M TRAPEZE KIT iB' DIA DRIU.ED (WB—Ti2-3) PROPOSED 1'-5• PIER FOUNDATION DIA, CONCRETE PIER (TYP) 11110 A —A SECTION ON s' DIA GALV SCH 40 IPE (SPACED 9'-0• UUt) (MF-130) CONCRETE PIER SIQE NO SCALE ] TYPICAL ICE BRIDGE CONCRETE PIER DETAIL No SCALE $ HYBRID CABLE RUN -E 40 s h �mw 5701 SOUTH SANTA FE DRIVE UTTLETON, CO 80120 Jacob& Challenging today. Reinventing tomorrow. Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD AC WORTH, GA 30102 N �N NSR�pI 5 : '�1 f''•. f �9• * No. 91030i A'. STATE OF :'tt.: o 1117110NALVE x�°` nmm�nlot0N i>gS liElt NAS BEEN ELECTRONICALLY SIGHED NO SEALED BY STEM {EN C, RICKOE USING A DIGITAL SIGNATURE N!D DATE PRINTED COPIES OF THIS DOCUIAENT ARE NOT CONSIDERED SIGNED AVO SEALEO AND TIE SIGNATURE MUST BE VERIFIED ON N!Y ELECTROI:IC COPIES ON R IS A ON OF LAW FOR ANY PERSON, UNLESS 7HEY ARE ACTING UNDER THE DIRECTION OF A DCEN$ED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KRK REDS REV: TBD OWN CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 0!/2!/10Q1 ISSUED FOR OONSTRUCRON A&E PROJECT NUMBER EUCC0309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE EQUIPMENT DETAILS SHEET NUMBER A=4 PCTEL GPSGL—TMG—SPI-40NC13 DIMENSIONS (DIAxH) MM/INCH 81084mm 3,2'x7,25' WEIGHT W/ACCESSORIES 075 ibe CONNECTOR N—FEMALE FREQUENCY RANGE 1590 t 3OMHz MINIMUM OF 75X OR 270 IN ANY DIRECTION GPS W 12PSMBP4)O(X (4 AWG CONDUCTORS) W12PSM9P8XXX (8 AWG CONDUCTORS) 0o q Lo �o•4,o R� B� W12PSM9PB)= (8 AWO CONDUCTORS) CABLES UNLIMITED HYBRID CABLE GPS DETAIL No SCALE � GPS MINIMUM SKY VIEW REQUIREMENTS No SCALE 2 No SCALE 3 MINIMUM BEND RADIUSES NOT USED Wit! ND scuE I 7 NOT USED � No scuE � 5 � NOT USED � No scALE � 6 � wr s h 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 Jacob& Challenging today. Reinventing tomorrow. Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 \ o Hl,l,l,,,,,, a e C omti`�QH No. 91030 STATE OF :�tt`: ONAI.E�� . °,ololnnn"o THIS 1iE1.1 HAS BEEN ELECTRWBCALLY SIGNED AND SEALED BY STEPS TO C. RWGE US94G A DIGITAE SIGNATURE AND DATE PUNTED COPIES OF THIS DOCILAAENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIOW.TURE lW ST RE VERIFIED ON PIN ELECTRMIC COPIES R IS A VIOlAT10N OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KRK RFDS REV: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A OE/TJ/2MI SSM FOR cownwaIgN A&E PROJECT NUMBER EUCC0309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE EQUIPMENT DETAILS SHEET NUMBER Am5 FUJITSU TA08025-8604 RRH DIMENSIONS (HxWxD) (KGAN) 380x4ODx200/14.9'x15.7'x7.8' WEIGHT(KG,LB)/ VOLUME 29kp,83,9Ib/ 30L POWER SUPPLY DC-58�-38V RAYCAP RDIDC-9181-PF-48 DC SURGE PROTECTION (OVP) DIMENSIONS (HxWxD) 18.98004.3970.15' WEIGHT 21.82 LBS cl o s� eecx SURGE SUPPRESSION DETAIL (OVP) M04 MOUNTING BRACKET HPA-33R—BUU—H4—K WIDTH 5' (135mm) DEPTH 2' (51mm) HEIGHT 8' (213mm) TOTAL WEIGHT 8RACKETS) 1.5 LBS 1540 Kg) HOUSING MATERIAL ABS ALUMINUM RADOME COLOR LIGHT GRAY CONNECTOR 1XS-PIN DNS( CHAIN FUJITSU TA08025—B605 RRH DIMENSIONS (HxWxD) (KG/IN) 38Ox400x230/14.9'x15.7'x9.0a WEIGHT(KG,LB)/ VOLUME 34kp,74.91b/ 35L POWER SUPPLY DC-58»-38V 0 ,f 7�iS[•IIi�7�7[7:1�1��7.7�i�ill� JMA WIRELESS MXMF_R0665-20 ANTENNA DIMENSIONS (HxWxD) 72.8'x20.06x8,0' TOTAL WEIGHT 84.5 LB RF PORTS, CONNECTOR TYPE 8 x 4,3-10 FEMALE COMMSCOPE XP-2040 CROSSOVER PLATE DIMENSIONS (HxW) 10702' WEIGHT 11.023 LBS C�] NO SCALE I 2 ANTENNA PLATFORM (NOT INCLUDED) ANTENNA PIPE MOUNT (NOT INCLUDED) COMMSCOPE BACK—TO—BACK MOUNT RR—FA2 21 DIMENSIONS (HxWxD) 18.41'08.000.0' WEIGHT 39.22 lb PACKAGE QUANTITY 2 iuA 0 11 �1�[•�I � �i717 [�7� [•Dl: i 7� �_11 � COMMSCOPE MC—PK8—DSH FACE WIDTH 98' WEIGHT 1373408 Ibm NOTE: 15' TO 38' O,D. HANDRNL ANTENNA ANTENNA PLATFORM DETAIL 1 r 19, ►� SGA.E 13 NO SCALE I 6 .sh Wkelftsm 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 Jacobs Challenging today. Reinventing tomorrow, Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 N oN Co '. , 40,00, *? No. 91030 STATE OF i i13S IiE1.11N5 SEEN ELECTROICCALLY SIGI:ED MID SEALED BY STEPf1EN C. RIDGE USING A DIGRAL SIGNATURE N!D DATE. PRINTED COMES OF THIS DOCDI.IENT ARE NOT COIISIDERED SIGNED MID SEALED MID THE 910 ATURE �NBT BE VFJGFIED ON AN ELECTRONIC COPIES R IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KRK RFDS REV {�: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A Oe/Y3/Y02I SSUFD FOR OONSRNCIION A&E PROJECT NUMBER EUCC0309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE EQUIPMENT DETAILS SHEET NUMBER Am6 NOTES DC POWER WIRING SHALL BE COLOR CODED AT EACH END FOR IDENTIFYING +24V AND —48V CONDUCTORS. RED MARKINGS SHALL IDENTIFY +24V AND BLUE MARKINGS SKILL IDENTIFY —48V. 1. CONTRACTOR SHALL FIELD VERIFY ALL PROPOSED UNDERGROUND UTILITY CONDUIT ROUTE. 2. ANTENNAS AND MOUNTS OMITTED FOR CLARITY. 43'-11' POUND AREA) 1'-3" 9'-10" 11'-0" 3'-7" 18'-3" ExlsnNc I I (4'X4') I EXISTING 34.5 AREA SQ FT ELEV. I� PLATFORM-------- x ! x x x x x x EXISTING I . (4'X6') a " GEN PAD/ + + •. AREA EXISTING PAD IN A (15' X 200) AREA I 00 EXISTING MONOPOLE — � TOWER < x I x EXISTING \\ EXISTING ICE �+ I I BRIDGE (TYPO I (56-0" X 1 1'-0") I I I II GEN PAD/AREA I; F -1 I L J x I �— - —\ EXISTING _ _ _ _ _ _ _ (4'X41) PAD I `ol z� _ I EXISTING EXISTING EQUIPMENT a (I6'X22') •' ', SHELTER o N PLATFORM (12'-0" X 20'-0") x o I q IIIIII ••• \ N PROPOSED z• Pvc— x UNDERGROUND FIBER CONDUIT (LENGTH: 34'f) EXISTING 56 SO FT PAD IN A (120X200) AREA " — — — —F x I X X X 1� EXISRNG 9'-8"UTILITY H-FRAME `PROPOSED METER ON PROPOSED FIBER EXISTING H-FRAME IN HANDHOLE 16'-0" 13 2 1 4'-4" SOCKET 'C'. PROPOSED 4• PVC UNDERGROUND 1'-2" CONDUIT ROUTED WITHIN UTILITY EASEMENT TO HANDHOLE AT PUBLIC ROW (LENGTH: 330't) PROPOSED 2° PVC UNDERGROUND POWER CONDUIT (LENGTH: 65't) UTILITY ROUTE PLAN 'j 1. CONTRACTOR SWV L INSPECT THE IXISTING CONDITIONS PRIOR TO SUBMITTING A BID. ANY QUESTIONS ARISING DURING THE BID PERIOD IN REGARDS TO THE CONTRACTOR'S FUNCTIONS, THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERK)) WITH THE PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. 2. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL ELECTRICAL CODES AND ALL STATE AND LOCAL CODES, LAWS, AND ORDINANCES. PROVIDE ALL COMPONENTS AND WIRING SIZES AS REQUIRED TO MEET NEC STANDARDS. 3. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE COORDINATED WITH FIELD CONDITIONS PRIOR TO CONSTRUCTION. 4. CONDUIT ROUGH —IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION CONFLICTS. VERIFY WITH THE MEC1A41CAL EQUIPMENT CONTRACTOR AND COMPLY AS REQUIRED. 5. CONTRACTOR SHALL PROVIDE ALL BREAKERS, CONDUITS AND CIRCUITS AS REQUIRED FOR A COMPLETE SYSTEM. 8. CONTRACTOR SHALL PROVIDE PULL BOXES AND JUNCTION BOXES AS REQUIRED BY THE NEC ARTICLE 314. 7. CONTRACTOR SHALL PROVIDE ALL STRAIN RELIEF AND CABLE SUPPORTS FOR ALL GABLE ASSEMBLIES. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS, 8. ALL DISCONNECTS AND CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED PHENOLIC NAMEPLATES INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM, 9. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS AND NEC 250, THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULL BOXES, AND ALL DISCONNECT SWITCHES, AND EQUIPMENT CABINETS, 10. ALL NEW MATERIAL SHALL HAVE A U.L LABEL 11. PANEL SCHEDULE LOADING AND CIRCUIT ARRANGEMENTS REFLECT POST —CONSTRUCTION EQUIPMENT. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR AS —BUILT PANEL SCHEDULE AND SITE DRAWINGS. 13. ALL TRENCHES IN COMPOUND TO BE HAND DUG. ELECTRICAL NOTES I NO SCALE �� I NO SCALE 2 3 • r s h 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 Jacobs Challenging today. Reinventing tomorrow. Jacobs Telecommunications, Inc 5449 BELLS FERRY ROAD ACWORTH, GA 30102 \oa,wuulNTu�T„ C, R/�c pot 3 * i• No. 91030 %* = i % A : STATE OF i�i,kA- :' F(OR10�: G�`�.`� I' VONAI�\... Tnnlnauan MSITEM NAB BEENELECTROIIM YSIGNEDAND SEMED BY BTEPNEN C. RME USYIG A DIGITAL SIOWTURE AIID DATE PPoNTEDCOPIESOF SDO WI NTARENOT CdISIDERED SIGNED AND SEALED AND THE BM.NATURE LR15T BE \'FAIFIED ONA ELECTRONIC COPIES R IS A VIOLATION OFLAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICQISED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: 1APPROVED BY: CRO WBP KIRK REDS REV jJ: TBD SEEM CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A O6/23/204I ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER EUCCO309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE ELECTRICAL/FIBER ROUTE PLAN AND NOTES SHEET NUMBER Eml SEE TRENCHING NOTE i DISH WIRELESS DISH WIRELESS LLC. FIBER DISTRIBUTION PANEL LLC. PROVIDES O O 0 TRENCHING NOTES WORK SPay�FICAT�wNS 12AWO WIRE (e' PROPOSED DISH 1, CONTRACTOR SHALL RESTORE THE (SEE GENERAL NOTES) TALL) Fl��C WIRELESS LLC. URE TRENCH TO ITS ORIGINAL DDS&SLOPE TO SUIT SOIL CONDITIONS BY EITHER SEEDING CONDITION IN ACCORDANCE OR SODDING GRASS AREAS, OR WITH LOCAL REGULATIONS REPLACING ASPHALT OR CONCRETE SEE TRENCHING NOTE 2 PROPOSED DISHSSWRELESS AREAS TO ITS ORIGINAL CROSS LLC* UNISTRUT SECTION, /// / / oo DISH WIRELESS LLC. FIBER 2. TRENCHING SAFETY, INCLUDING, ' \\ / JUMPER TO CABINET WILL BUT NOT LIMITED To SOIL q //%\ /�/ R� PROVIDER O OTHER SHORING, SHALL BE GOVERNED WIRELESS LUASSIFICATIONs SLOPINGo AND Am PROPOSED DLCH, CONNECTOR WHERE o0o" SIDE OF CIRCUIC MT BY THE CURRENT OSHA a 10 AMP DISTRIBUTION IS TERMINATED. TRENCHING AND EXCAVATION // '•� ' / BREAKER""St SAFETY STANDARDS, 3, ALL CONDUITS SHV.I. BE W // .^ F DS IN IN INSTALLED IN COMPUANCE WITH ni i :` z. FIBER PROPOSED FIBER FROM RIGHT tin THE CURRENT NATKWAL , / PROPOSED DISH WIRELESS LLC, O 0 FI WAY TO STREET, ELECTRIC CODE (NEC) OR AS LlITLtTY WARNING TAPE 12 AWO WIRE TERMINATED TO FOP PROPOSED DISH WIRELESS LLC. REQUIRED BY THE LOCAL SAND BEDDING PER SITE 1-1/2' POWER FROM CJJ3INET PROPOSED DISH WIRELESS LLC. JURISDICTION, WHICHEVER IS WORK SPECIFICATIONS i-1/2' FIBER TO CABINET THE MOST, STRINGENT DISH WIRELESS LLC. INSTALLS i-1/2' CONDUITS FOR POWER PROPOSED DISH WIRELESS LLC. AND FIBER TO CABINET 2' CONDUIT FROM COMMERCIAL FIBER VAULT NOT USED NO SCALE TYPICAL UNDERGROUND TRENCH DETAIL NO SCALE 2 DARK TELCO BOX — INTERIOR WIRING LAYOUT TNO scALE 3 swommellm SENSE NOTE FIBER PROVIDER PROPOSED FIBER WILL NEED TO PROVIDE AN PRONID, IF REQUIRED ADDITIONAL SFT UNISTRUT, �� DISH WIRELESS 2 U—BOLTS WITH 4 NUTS, L.L.C. UNISTRUT IN THE EVENT THE BRACKET SPACING DOESN'T UNE UP WITH CURRENT SPACING BELOW PROPOSED FIBER PROVIDER IN IN OUT 1-1/4' FLEX CONDUITS FIBER PROVIDER TO TERMINATE FIBER PROVIDER TO PUNCH TOP OF POWER TO FIBER PROVIDER NO TELCO BOX OF NID ENCLOSURE AND PROPOSED DISH WIRELESS INSTALL 1-1/4' LIQUID TIGHT LLC. 12 AWG WIRE (8' TAICONNECTORS, UL LISTED, NYLON MATERIALS, WITH 0—RING GASKET FIRER PROVIDER TO INSTALL PROPOSED DISH WIRELESS 1-1/4' FLEx CONDUITS BETWEEN LLC. FOP TELCO BOX & NID 10 AMP DISTRIBUTION BREAKER PROPOSED DISH WIRELESS L.L.C. PROPOSED DISH WIRELESS TELCO FIBER ENCLOSURE LLC* PROPOSED DISH WIRELESS L.L.C. 12 AWG WIRE ic:\m 1-1/2' FIBER TO CABINET N M r PROPOSED DISH WIRELESS PROPOSED DISH WIRELESS LLC. LLC. 2' CONDUIT FROM 1-1/2' POWER FROM CABINET COMMERCIAL FIBER VAULT LIT TELCO BOX —INTERIOR WIRING LAYOUT (OPTIONAL) No SCALE 4 NOT USED No SCALE 5 NOT USED T' No SCALE 6 SEEM NOT USED NO SCALE 7 NOT USED NO SCALE 8 NOT USED No SCALE 9 s h W�elftsm 5701 SOUTH SANTA FE DRIVE UTTLETON, CO 80120 vacob& Challenging today. Reinventing tomorrow, Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD AC WORTH, GA 30102 ` olililllNl„ ��Q0 to... DOE No. 91030 r * �_ -off; STATE OF 44� , 4 Do Di FSS/ONIA�Eflo�G�. iWSITE1.1 MAS SEEN ELECTROIFC L YSIGNED AND SEP1E0 BY B1EPFIEN C. RIDGE USNIG A DIGITAL SIGNATURE PllD DATE. PRINTED COPIES OF THIS DOCUAENT ARE NOT CONSIDERED SIG NED ANO SEAL EO ANO THE SIGNATURE AAI$T BE VERIFIED ON ANY ELECTROI:IC COPIES Flown LT IS A NOTATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A DCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP mmillp KRK REDS REV #: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A OS/13/20ZN ISSUED FOR OOIISIRUCIgN A&E PROJECT NUMBER EUCCO309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE ELECTRICAL DETAILS SHEET NUMBER E=2 0 0 A D 0 0 B E M C F (3) 3/0 WITH /8 GROUND IN 2' SON 40 CONDUIT PROPOSED POWER PROTECTIVE CABINET UTILITY SERVICE ENTRANCE 120/24OV, 1 PH, SERVICE RATED, UTILITY UVAC 1PH OVERALL UL LISTED POWER CENTER, N3R, 85K/tOK NC EXISTING MULTI -METER CENTER MAIN BREAKER WITH CAMLOCKENERAT 200A 0 200A INEEE�2CCKE 8GK GENERATOR AIC GEN PLUG F N OTC, 71F 4 1 v 0 IN :ter PROPOSED 2 /10, 1 {10 CU GND. (i) PROPOSED 0.5' EMT CONDOR FOR RECTIFlERS / 8: 2 BRANCH CIRCUIT WIRING SUPPLYID RECTIFlERS ARE TO 8E RATED UL1015, 105C, BOOV, ANO PVC INSULATED, IN THE SIZES SHOWN IN THE ONE -LINE DUtCi1tAM. CONTRACTOR MAY SUBSTITUTE UL1015 WIRE FOR TMNN-2 FOR CONVENIENCE OUTIET BRANCH CIRCUIT. .. • �0 .m NO SCALE ' `z NOT USED NOTES CONDOR SIZING: AT 40% FILL PER NEC CHAPTER 9, TABLE 4, ARTICLE 358. CONDUIT - 0.122 SQ. IN AREA 0.75' CONDUIT - 0213 SQ, IN AREA CONDUIT - 1.318 SQ. IN AREA n- rywmiIi - 9 am CO. IN Amu CCN1tENIENCE o 111 CONDUCTORS (1 CONDUIT): USING THMM-2, CU. 10 - 0.0211 SQ. IN X 2 m 0.0422 SQ, IN 10 - 0.0211 50. IN X 1 m 0.0211 SQ. IN <GROUND TOTAL • 0.0633 SO. IN TOTAL OF (3) WIRES, DING GROU D WIRE, AS INDICATED ABOVE. RECTIFlER CONDUCTORS (3 CONDUITS): USING UL10150 CU. /8 - 0.0552 SQ. IN X 2 � 0.1103 SQ. IN 8 - 0.0131 SO. IN X 1 = 0.0131 SQ. IN <BARE GROUND TOTAL • 0.1234 SQ. IN 0.75 ' EMT CONDOR IS ADEQUATE TO HANDLE THE TOTAL OF (S) WIRES, INCLUOINO GROUND WIRE, AS INDICATED ABOVE. PPc FEED CGNDUGTQRS (i CONDOR): USING THWN, CU. 3/0 - PPc FEED CGNDUGTQRS (i CONDOR): USING THWN, CU. 3/0 - 0.2879 SQ. IN X 3 = 0.8037 SQ. IN /8 - 0.0507 SQ. IN X 1 � 0.0507 SQ. IN <GROUND TOTAL m 0.5544 SQ. IN 3.0' SCH 40 PVC CONDOR IS ADEQUATE TO HANDLE THE TOTAL OF (4) WIRES, INCLUDING GROUND WIRE, AS INDICATED ABOVE. D SGNE 11 ..sh whiel fts. 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 Jacob& Challenging today. Reinventing tomorrow. Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 * N04 91030 . STATE OF � do �. onFSS/ONA1 04446 ' E'\�� "p,n,mmmto°` I NIS ITEIA HAS BEEN ELECTRONICALLY SIGHED AND SEAIED BY STEPf1EN C. RIDGE USBiG A DIGITK SIG!"TURE N#) DATE PRIIrtED COPIES OF PITS DOCUTAENT ARE,IOT CONSIDERED SIGNED A!ID SEALED AND mE SVIATURE VUST BE VERIFIED ON AIN ELECTRONIC COPIES IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS 1HEY ARE ACTING UNDER THE DIRECTION OF A DCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KRK RFOS REV #: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A OS/2J/202I ISSUED FOR OONSTRUCtION A&E PROJECT NUMBER EUCCO309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E, SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE ELECTRICAL ONE -LINE & PANEL SCHEDULE SHEET NUMBER E=3 TEST W'LLEl T� BOND PROPOSED EQUIPMENT I I PLATFORM TO PROPOSED mallo GROUNDING ELECTRODE SYSTEM (TYPE 4) . BOND H-FRAME POST TO NI -STRUT /2 AWG BURIED GROUND RING 30' BELOW GRADE PROPOSED 4'x12'x1/4' TINNED COPPER GROUND BUSSBAR ft if / `1\ MN nNLIQtin TiGHTD ICON/DUT ! I FROM 24' BELOW GRADE I ® I TO WITHIN r TO 8' OF 0 CAD -WELD TERMINATION , POINT. EXPOSED END OF �- — • — -� ® ®, , / THE LIQUID TIGHT CONDUIT MUST BE SEALED WITH SILICONE CAULK. (TYP) �-•-•-�.---•--1• .-- 1-RTC.-� ` ---- �, BOND EQUIPMENT AS REQUIRED BY MANUFACTURER \ �rvv RING (FEILD VERIFY) BOND ICE BRIDGE SUPPORT POSTS TO ND(t) \ GROUND RING BO- - — - - (TYP ALL POSTS) EXISTING MONOPOLE \ NOTES a 1 • � • ra a- 1 • -a a -a • • D 4'x8'x1/4' TINNED SECTOR GROUND (TYP OF 3) D UPPER TOWER GROUND NOTE R) D BUSS BAR RS (TYP) TYPICAL ANTENNA GROUNDING PLAN "° SCALE 12 •. 1 o-• 1 -•1 ------ F2 AWO STRANDED & INSULATED — • — j2 AWG SOLID COPPER TINNED GROUNDING LEGEND 1. GROUNDING IS SHOWN DIAGRAMMATICALLY ONLY. ] T 13 1 •.a' r GROUNDING KEY NOTES Oa•tpp •,: :.•. . I :, f r 1 .•... r - al 1 a• • 1 « a. : a i • •PER • I as"pop~111111114 No" • a•MilMIR l • a I •a• a- • a • a «• r •a al •: • • N A SITE SHALL BE GROUNDED TO THE INTERIOR GROUND RING WITH #6 AWO STRANDED GREEN LATED CONDUCTOR. • Im -,aa 1 •-•r «• 1 •• © a,lla; �•: a,ll:• i•;1 dd ,I :.:« • al a to a I :• 1 • -• I• �• 1 al «•••a• ra 1 •- a • a- a 1 • "I.IYAwl BOND TO BOTH CELL REFERENCE GROUND BAR OR DMIOR GROUND RING. ::•„4,d BONDING •• •' TELECOM a a.GROUND )T ISOLATED FROM THE EQUIPMENTS METAL FRAMEWORK, vllln uvr '!lEvItims METAL FRAMES, CABINETS AND INDMDUAL METALLIC UNITS LOCATED WITH THE AREA • INTERIOR GROUND lal •aa I w••r >• 1 TO THE a • GROUND RINGe • a r /• •• 1 al • 1 r•..•r 31 O1 • • • a• a ra. ► 1 1 • a• . a• • 11 • a• 1 • a, a' 1• • .. r r a a 1 r • - a. • 1 •• a- a• a • a• a• «• • - a- 1 • • a- a • a1 • a- 1 a • • r «• 1 • • • • 1 • • a- a • • 1 r• al • «a a a a • 1Ell REFER TO DISH WIRELESS LLC. GROUNDING NOTES. GROUNDING KEY NOTES NG SCALE 13 • .,sh Wkel"su 5701 SOUTH SANTA FE DRIVE UTTLETON, CO 80120 Jacobs, Challenging today. Reinventing tomorrow. Jacobs Telecommunicatiom, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102N 14ACe 10i0. A,_ =•o L. STATE OF • cv`F ?�'• F P OR �� O�SS%ONAL EV \`• '011NmI11110, k TW S IIEIA HAS BEEN ELECTRONICALLY SIGNED A O SEALED BY STE%IEN C. RIDGE USlUG A DIGITAL SIGNATURE N!D DATE PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEAIED AND THE SIGNATURE 4W ST BE VERIFIED ON ANY ELECTRONIC COPIES IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A 110ENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT, DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KRK RFDS TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A DO/7S/2l#I RSUFD FOR CONSIRUOIIDN A&E PROJECT NUMBER EUCCO309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE GROUNDING PLANS AND NOTES SHEET NUMBER G-1 /2 TINNED SOLID IN 1/2' MIN. LIQUID TIGHT CONOUIT FROM 24' BELOW GRADE TO WITHIN 3TO 8' OF CAD —WELD TERMINATIONI POINT, EXPOSED END OF THE LIQUID TIGHT CONDUIT MUST BE SEALED WITH SILICONE CAULK. (TYP) — o PROPOSED SIEVE BOX. SPACED RESERVED IF REQUIRED. _ ---------- PROPOSED TELCO FIBER L-------------1 ENCLOSURE .SYSTEM (TYP)�- MIS ax7flipill06 Jo TYPICAL GPS UNIT GROUNDING No sCALE \ �— PROPOSED GROUND RING H—FRAME GROUNDING DETAIL No scELE � QUTDOOR CABINET GROUNDING No scELE 12' DIA x 24" DEEP /2 TINNED SOLID IN 1/2" MIN. LIQUID INSPECTION SLEEVE PVC a� OR SOIL PIPE WITH CAP TIGHT CONDUIT FROM 240 BELOW GRADE 3 OR EQUIVALENT TO WITHIN 3' TO 8' OF CAD —WELD PIPE , 1'-0' TERMINATKIN POINT. EXPOSED END OF �� N THE LIQUID TIGHT CONDUIT MUST BE ,i FINISHED GRADE INCLUDE WARNING TAPE WITH SEALED WITH SILICONE CAULK, ° . o. o- o D b:.o D D.o oo a 0 BACKFlLL PER SPECIFICATIONS GRADE ° O O ° °. o, o ° .°. O. O.O O . Lisa EXOTHERMIC CONNECTION 3/4" CRUSHED STONE OR EQUAL FILL TEST WELL TO . all WITHIN 2' OF TOP OF GROUNDING LOOP CONDUCTOR � GROUND RING, /2 AWC SOLIMVEL (TYP) I I I GROUND RING / / T PER CONDUBARE CTOR /2 AWG SOLID TINNED TIE INTO EXISTING COPPER CONDUCTOR GROUND RING EXTERIOR GROUND RING GROUND R00, 1/2' MIN. x 8'-0' LONG COPPER CLAD STEEL (ERICO /82WW) TRANSITIONING GROUND DETAIL NO SCALE 4 TYPICAL TEST GROUND ROD WITH INSPECTION SLEEVE ND SCALE 5 TYPICAL GROUND RING TRENCH NO SCALE 2 3 y OF s h ��m 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 Jacobs. Challenging today. Reinventing tomorrow. Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 QHEN C �6t E N Sf ��F''% * �4 No. 91030 ; _ * c STATE OF .•'��.`: �'l/llllllllllll\�T TWsITEl.1 HAS BM EL[GTRO45 A SI Alro SEPIED DY STEPf150 C.RIDGEF DI SI AOCUAF SIGNATURE AIiD GATE. PRiNTENCOPIESOE THIS DDPIES ARELOT CONSIDERED SIGNED AND SEABED AND PIE EO COPIES AW ST BE VERIFIED ON N1Y ELECTRONIC COPIES R IS A NOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A DCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KRK RFDS TED CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A OE/Zl/2MI ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER EUCCO309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE GROUNDING DETAILS SHEET NUMBER G-2 a • a- a l • f2 AW4 211E TIAAED Vf1TEfVWeER TO GALIAD ROUTE CONDUCTORS T• BURIED GROUND RING AND PROVIDE PARALLELEXOTHERMIC W 2* ALL ]',I' GROUNDING HARDWARESHALL]S ]] DIAMETER OR LARGER. ALL HARDWARE 18*ooS STAINLESS STEEL INCLUDING LOCK WASHERS, COAT ALL SURFACES WITH AN ANTIoo*OXIDANT COMPOUND BEFORE MATING. FOR GROUND BOND• STEEL ONLY: • ]. WITH AN ANTIwwoOXIDANTCOMPOUND BEFORE 4o DO NOT INSTALL CABLE GROUNDING KIT AT A BEND AND ALWAYS DIRECT GROUND CONDUCTOR DOWN TO GROLINDING BUS. WASHER SHALL BE PLACEDa ON -INT SIDE OF •• • BAR AND BOLTED THE BACK I S. ALL GROUNDING PARTS AI EQUIPMENT TO BE SUPPLIED AND INSTALLED ErY CONTRACTOR, 7* THE CONTRACTOR SHALL BE RESPONSIBLE ... INSTALLING ADDMONALGROUND BAR AS go ENSURE THE WIRE INSULATION 7MINATION IS WITHIN 1/8" OF THE BARREL (NO SHINERS). TYPICAL GROUNDING NOTES NOTE: MINIMUM OF 3 THREADS TO BE VISIBLE (TYP) —� NOT USED S/S ELT (TYP) S/S SPLIT WASHER (TYP) S/S FIAT WASHER cTYP) S/S FLAT WASHER (TYP) S/S NUT (TYP) EXTERNAL TOOTHED DIA x1 1 S/S NUT � S/S LOCK WWASHER S/S FLAT WWASHER s/s B01.T c, DF z)• 8' MINIMUM SPACING CLOSED BARREL. FOR ALL BLACK HEAT ORQ?IOR_TWO—HOLE SHRINK W Y11:Iilal� �Ja;7 TYPICAL EXTERIOR TWO HOLE LUG NOT USED EXLERNAL T001HED — 3/8' DU xt S/S NUTbook S/S LOCK WWASHER — S/S FIAT WASHER s/s BOLT MINIMUM SPACING CLEAR HEAT TYPICAL INTERIOR TWO HOLE LUG NOT USED ♦ I •1 0 jNN3 NG SCALE g .,sh WW"su 5701 SOUTH SANTA FE DRIVE LJTTLETON, CO 80120 Jacob Challenging today. Reinventing tomorrow. Jacobs TelecOmmunicallons, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 ,011n+ eN Nsk/p��^, STATE OF :�ck. 6 OR 0 Pot °�SStONALV 1lONnuuaTT \\Wow THIS IIEI.+HAS BEEN ELECTRONICALLY SG "NW SEALED BY STEPFU4 C. ROE US0IG A DIGITAL SIGWURE AND DATE PRIITfED COPIES OF THIS DOCU RENT ARE NOT CONSIDERED SIGNED AND SEALED AND PIE SIGNATURE \LUST BE \ER+FIED ON NN ELECTRONIC COPIES R IS A NOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LJCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT, MEN DRAWN BY: CHECKED BY: 1APPROVED BY: CRO WBP KIRKRFDS REV: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 06/27/2021 63UED FOR CONSTRUCTION A&E PROJECT NUMBER EUCC0309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE GROUNDING DETAILS SHEET NUMBER G=3 ONE RF JUMPER COLOR CODING 3/4' TAPE WIDTHS WITH 3/4' SPACING ALPHA RRH BETA RRH GAMMA RRH LOW BANDS (N71+N26) AWS PORT 1 PORT 2 PORT 3 PORT 4 d.sh PORT 1 PORT 2 PORT 3 PORT 4 PORT 1 PORT 2 PORT 3 JORANGE OPTIONAL — (N29) (N66+N7O+H—BLOCK) LOW —BAND RRH — + SLANT — SLANT + SLANT — SUM +SLANT —SLANT +SLANT —SLANT +SLANT —SLANT +SLAM (600MHz N71 BASEBAND) + GoottoottooORANGE P(850MHz N26 BAND) +(70OMHz N29 BAND) — OPTIONAL PER MARKET RED RED RED RED BLUE BLUE BLUE BLUE GREEN GREENORANGE ORANGE RED RED ORANGE ORANGE BLUE BLUE ORANGE ORANGE GREEN ADD FREQUENCY COLOR TO SECTOR BAND CBRS TECH NEGATIVE SLANT PORT(CBRS WILL USE YELLOW BANDS) too ORANGE ORANGE ORANGE ORANGEtoo ORANGE (3 GHz) ON ANT/RRH YELLOW WHITEtoo "D RED RED RED RED BLUE BLUE BLUE BLUE GREEN GREEN GREEN GREEN ALPHA SECTOR BETA SECTOR GAMMA SECTOR MID —BAND RRH — (AWS BANDS N66+N7O) RED BLUE GREEN PURPLE PURPLE RED RED PURPLE PURPLE BLUE BLUE PURPLE PURPLE GREEN GREEN _ PURPLE PURPLE _ PURPLE PURPLE _ PURPLE PURPLE ADD FREQUENCY COLOR TO SECTOR BAND (CBRS WILL USE YELLOW BANDS) - COLOR IDENTIFIER NO SCALE 2 HYBRID/DISCREET CABLES EXAMPLE 1 EXAMPLE 2 EXAMPLE 3 RED RED RED INCLUDE SECTOR BANDS BEING SUPPORTED BLUE BLUE ALONG WITH FREQUENCY BANDS 014, GREEN GREEN ORANGE EXAMPLE 1 — HYBRID, OR DISCREET, SUPPORTS PURPLE ALL SECTORS, BOTH LOW —BANDS AND MID —BANDS ORANGE YELLOW EXAMPLE 2 — HYBRID, OR DISCREET, SUPPORTS PURPLE CBRS ONLY, ALL SECTORS FIBER JUMPERS TO RRH8 LOW BAND RRH HIGH BAND RRH LOW BAND RRH HIGH BAND RRH LOW BAND RRH HIGH BAND RRH LOW —BAND RRH FIBER CABLES HAVE SECTOR STRIPE ONLY RED RED BLUE BLUE GREEN GREEN PURPLE PURPLE PURPLE POWER CABLES TO RRHs LOW BAND RRH HIGH BAND RRH LOW BAND RRH HIGH BAND RRH LOW BAND RRH HIGH BAND RRH LOW —BAND RRH POWER CABLES HAVE SECTOR STRIPE ONLY RED REO BLUE BLUE GREEN GREEN NOT USED NO SCALE 3 PURPLE PURPLE PURPLE RET MOTORS AT ANTENNAS ANTENNA 1 ANTENNA 1 ANTENNA 1 ANTENNA 1 ANTENNA 1 ANTENNA 1 LOW BAND/ HIGH BAND/ LOW BAND/ HIGH BAND/ LOW BAND/ HIGH BAND/ 'IN' 'IN' 'IN' 'IN' 'IN' 9N' RED RED BLUE BLUE GREEN GREEN PURPLE PURPLE PURPLE MICROWAVE RADIO LINKS FORWARD AZIMUTH OF 0-120 DEGREES FORWARD AZIMUTH OF 120-240 DEGREES FORWARD AZIMUTH OF 240-360 DEGREES LINKS WILL HAVE A 1.5-2 INCH WHITE WRAP WITH PRIMARY SECONDARY PRIMARY SECONDARY PRMARY SECONDARY THE AZIMUTH COLOR OVERLAPPING IN THE MUDDLE. ADD ADDITIONAL SECTOR COLOR BANDS FOR EACH ADDITIONAL MW RADIO. WHITE WHITE WHITE WHITE WHITE WHITE MICROWAVE CABLES WILL REQUIRE P—TOUCH RED to RED BLUE BLUE GREEN GREEN LABELS INSIDE THE CABINET TO IDENTIFY THE WHITE WHITE WHITE WHITE WHITE WHITE LOCAL AND REMOTE SITE ID'S RED BLUE GREEN WHITE WHITE WHITE RF CABLE COLOR CODES NO SCALE j NOT USED NO SCALE 4 5701 SOUTH SANTA FE DRIVE LITTLL7ON, CO 80120 Jacobs. Challenging today. Reinventing tomorrow. Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 Illlllgl,l ,�,5�%QN �N NSR%p�;o, =-o ••. STATE OF lllllll 111\\\\\ iHI51TE1.1 HAS BE EN ELELIROIIILALLY SIGIIED AlID STALLED BY BTEPHEH C. RIDGE USItIG A DIGITAL SIG'UTURE AlID DATE. PRIlRED COPIES OF THIS DOCUTAEUT ARE HOT CpIEIDERED SIGNED MID SEALED AND TI1F BIG'NTURE MUST BE \ERIFIED O� N!V ELECTROI.IC COPIES R IS A NOTATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT, DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KIRK RFDS REV #: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A OE/zJ/20z1 LSSIIFD FOR 0016TRI1C110N A&E PROJECT NUMBER EUCCO3O9 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE RF CABLE COLOR CODES SHEET NUMBER RF-1 As1L PHA BETA GAMMA MXOBFR0665.20 £lf.7S • MXOSFRO665-20 J. MX08FRO665-20 MM Band top Low Band 04 1 T Fiber Patch Panel Mid Band Bottom Row Pair 1 Pair 2 Pair 3 Pair 10 Open Open Middle Row Pair 4 Pair 5 Pair 6 Palr 11 Open Open Top Row Pair 7 11tairS jPaIr9 1PsIr12 Open lopen O I )l OttOTTI Bottom OVP Layout I I Ckcuit 1 Alpha Low Band I Bottom OVP 1 Specific OVP modelnumber t Circuit 2 Beta Low Band 1 detailed In Circuit 3 Gamma Low Band I RFos I Circuit 4 Alpha Mid Band I I Circuit 5 Beta Mid Band I Circuit 6 Gamma Mid Band I 1 I Circuit 7 Alpha CBRS I - - - - - 1 - - Circuit8 Beta CBRS j I i I Circuit 9 Gamma CBRS I Circuit 10 Open - - - - - - - _ -- -- - -- - - - - - - -- -- ---- -- _ - _ _' CircuitOpenI 11 Circuit 12 Open 543 plumbing diagram JMA MX08FR0665.20 2-2.2(LB+MB) _ 1 S-IIry 2021 Avid Bor+ I I 1 PLUMBING DIAGRAM 1 ALT , n ow Band a mV asa$$aa$$aP$r+ �T Mid Band CSR NCS540 PON In1ertJ[e Descnpuon 0 GA000 SIteBOss 1 GA6{v1 CBRS,Adpha 2 GIB0102 CBRS - Beta 3 G&OW CBRS - Gamrrla J Te"Opil Funsu LI -Band RU -A a 5 Te0DVS Funsu lAid Band RU-Alpha 6 Te"013 Fuldlitt LOW -Band RU -Bela 7 TE00Nr Fu nsu Mad Band RU - Beta 8 Te0KT04 Fuiasu LoA••Band RU - Gamma 9 Te0.009 oFtqftsu IM-Band RU - Gamma f0 TeO"10 F1aed Wh 11 Te040'll FOfed WR 12 Te000112 Fixed W l 13 Te060P13 Fixed W5h 1J TeGUO014 CORS1 15 Teo 0&15 CBRS2 16 Te0V.01G CORS3 SMI &AC - 17 G1000'I7 18 CADIDN16 S142. 8MC 19 Te00.019 S1.11 - Data 1 2O TeD0020 IStill . Data 2 21 7e00MI SM2 - Data 1 22 ---r a22 23 - 9.1:-C-it T£ zJ 25 --:JUT: - 16 Te00O25 FAti'1 7"1 V, 27 7e00027 2B Teo*028 31wkyFutule 29 Te69429 O!anu Future 0o n -I L1tL0 - t�: l ePat. I. H n �I.1 a NO SCALE I '� \I ..sh 5701 SOUTH SANTA FE DRIVE L TTLETON, CO 80120 Jacob& Challenging today. Reinventing tomorrow. Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 sLSLs1111111Irrrr/ Q�fN C. j °Oa No. 9103 =Ai STATE OFgo so so '�.go:.Pt P 0RIO:G v�.• SS/ONAL nn,NlmwTa MS ITEM MAS BEEN ELECTRONICALLY SIGNED AND SEALED BY STE%Ell C. RAGE USER: A DIGITAL SIGNATURE AIA DATE %TINTED CONES OF TNIS DOCLIMENTARE NOT CONSIDERED SIGNED MD SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTROI:TC COPIES R IS A VIOlAT10N OF LAW FOR ANr PERSON, UNLESS THEY ME ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT, DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KIRK REDS REV �: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A Oe/2A/202I ISSUED FOR CONSTRUCTION Ad E PROJECT NUMBER EUCC0309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 Ea SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE RF PLUMBING DIAGRAM SHEET NUMBER RFw2 AB ANCHOR BOLT IN INCH EXOTHERMIC CONNECTION • ABV ABOVE INT INTERIOR MECHANICAL CONNECTION IN AC ALTERNATING CURRENT LB(S) POUND(S) ADDL ADDITIONAL LF LINEAR FEET CHEMICAL. ELECTROLYTIC GROUNDING SYSTEM e AFF ABOVE FINISHED FLOOR LYE LONG TERM EVOLUTION TEST CHEMICAL ELECTROLYTIC GROUNDING SYSTEM eT AF0 ABOVE FINISHED GRADE MAS MASONRY AGL ABOVE GROUND LEVEL MAX MAXIMUM EXOTHERMIC WiTH INSPECTION SLEEVE © NC AMPERAGE INTERRUPTION CAPACITY MCL MOUNT CENTER LINE GROUNDING BAR o ALUM ALUMINUM MB MACHINE BOLT GROUND ROD I�� ADT ALTERNATE MECH MECHANICAL. ANT ANTENNA MFR MANUFACTURER TEST GROUND ROD WITH INSPECTION SLEEVE II�T APPROX APPROXIMATE MGB MASTER GROUND BAR ARCH ARCHITECTURAL MIN MINIMUM SINGLE POLE SWITCH ATS AUTOMATIC 7RANSFER SWITCH MISC MISCELLANEOUS $ AWO AMERICAN WIRE GAUGE MTL METAL DUPLEX RECEPTACLE BATT BATTERY Mors MANUAL TRANSFER SWITCH BLDG BUILDING MIN MICROWAVE DUPLEX GFCI RECEPTACLE BLK BLOCK NEC NATIONAL ELECTRIC CODE BIKG BLOCKING NM NEWTON METERS I-------i BM BEAM NO. NUMBER FLUORESCENT LIGHTING FIXTURE I F I BTC BARE TINNED COPPER CONDUCTOR (2) TWO LAMPS 48-- ---- T8 LJ BOF BOTTOM OF FOOTING III NUMBER NTS NOT TO SCALE CAB CABINET O OC GN-CENTER SMOKE DETECTION (DC) CANT CANTILEVERED OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION CHO CHARGING OPNG OPENING EMERGENCY LIGHTING (DC) CCLR CEILING P/C PRECAST CONCRETE SECURITY LIGHT W/PHOTOCELL LLTHONIA ALXW COL COLUMN PCS PERSONAL COMMUNICATION SERVICES LED-1-25A400/51K-SR4-120-PE-DDBTXD COMM COMMON PCU PRIMARY CONTROL UNIT CHAIN LINK FENCE x x x X CONIC CONCRETE PRO PRIMARY RADIO CABINET PP POLARIZING PRESERVING WOOD/WROUGHT IRON FENCE �� CONSTRUCTION ON PSF POUNDS PER SQUARE FOOT BLE PSI POUNDS PER SQUARE INCH WALL STRUCTURE DC DIRECT CURRENT Pi PRESSURE TREATED LEASE AREA — — — — — — — — — — — — — OF DDEPT DEPARTMENT NTOUGLAS PWR POWER CABINET CITY QUANTITY PROPERTY LINE (PL) - - - - - - DIA DIAMETER RAD RADIUS SETBACKS DLAG DIAGONAL RECT RECTIFIER - - - - - - - - - - - - - - - - - - - - - - - - - DIM DIMENSION REF REFERENCE ICE BRIDGE Dom' DRAWiNG REINF REINFORCEMENT CABLE TRAY OWL DDOOWEL REWD REQUIRED WATER LINE — W W W W W — EC ELECTRICAL CONDUCTOR RET REMOTE ELECTRIC TiLT EL ELEVATION RF RADIO FREQUENCY UNDERGROUND POWER — UGP — UGP — UGP — UGP — UGP — ELEC ELECTRICAL RMC RIGID METALLIC CONDUIT UNDERGROUND TELCO — Uar — UGT — UGT — UGT — UGT — EMT pF META,M TUBING RRH REMOTE RADIO HEAD ENG ENGINEER RRU REMOTE RADIO UNIT OVERHEAD POWER OHP—OHP—OHP GNP— EQ EQUAL RWY RACEWAY OVERHEAD TELCO art oNF oNr art EXP EXPANSION SCH SCHEDULE IOR SHT SHEET UNDERGROUND TELCO/POWER — UGT/P — UGT/P — UOT/P — UGT/P — EEWW EiCHWAY SIAD SMART INTEGRATED ACCESS DEVICE ABOVE GROUND POWER — AGP — AGP — AGP — AGP — AGP — FAB FABRICATION SIM SIMILAR ABOVE GROUND TELCO — AGT — Aar — Aar — AGT — AGT FF FINISH FLOOR SPEC SPECIFICATION FG FINISH GRADE SQ SQUARE ABOVE GROUND TELCO/POWER — AGT/P — ACT/P — AGT/P — AGT/P FIF FACILITY INTERFACE FRAME SS STAINLESS STEEL FIN FINISHED) STD STANDARD WORKPOINi STL STEEL W.P. FLR FLOOR TEMP TEMPORARY SECTION REFERENCE FOC �ECONCRETE THK THICKNESS FOM FACE OF MASONRY TMA TOWER MOUNTED AMPLIFIER DETAIL REFERENCE TN TOE NAIL X-X FOS FACE OF STUD TOA TOP OF ANTENNA FOW FACE OF WALL Toe TOP OF CURB FS FINISH SURFACE TOF TOP OF FOUNDATION Fr FOOT TOP TOP OF PLATE (PARAPET) FTG FOOTING CA CADGE TOS TOP OF STEEL GEN GENERATOR TOW TOP OF WALL GFCI GROUND FAULT CIRCUIT INTERRUPTER 1VSS TRANSIENT VOLTAGE SURGE SUPPRESSION GLB GLUE LAMINATED BEAM TYP TYPICAL. GLV GALVANIZED UG UNDERGROUND GPS GLOBAL POSITIONING SYSTEM UL UNDERWRITERS LABORATORY GND GROUND UNO UNLESS NOTED OTHERWISE GSM GLOBAL SYSTEM FOR MOBILE UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM HOG HOT DIPPED GALVANIZED UPS UNITERRUPTIBLE POWER SYSTEM (DC POWER PLANT) HDR HEADER VIF VERIFIED IN FIELD NOR HANGER W WIDE NVAC HEAT/VENITLATiON/AIR CONDITIONING W/ WITH HT HEIGHT WD WOOD IGR INTERIOR GROUND RING WP WEATHERPROOF WT WEIGHT LEGEND ABBREVIATIONS .sh 5701 SOUTH SANTA FE DRIVE UTTLETON, CO 80120 Jacob& Challenging today. Reinventing tomorrow. Jacobs Telecommunicallons, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 luuuunn! QWEN C. No. 91030 1 STATE OFgo :art;: • �.A .;oC GRIDPo&Z;F %FSS%ONA1 E'�.`` rrrrrp NI N1111p!\`\ THIS 1TEI.1 RAS OPEN ELECTRONICALLY SIGHED AND SEALED BY STEPHEN C. RIDGE USM A DIGITAL SIGNATURE ANO DATE. PWNTEDCOPIESOE THISD IARENOT COliEIDERED SIGNEDAND SEXED AND PIESIGNATURE MUST BE \EAIFIED ON MN ELECTRONIC COPIES COPIESIES ommmossomm R IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY; go 1APPROVED BY: CRO WBP googgogg KRK REDS REV #: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A OE/2J/102I RBIIED FOR OONSTRUCTION A&E PROJECT NUMBER EUCC0309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TiTLE LEGEND AND ABBREVIATIONS SHEET NUMBER GN-1 11 1►tl� : • : „hi5►-�i 1. NOTICE TO PROCEED - NO WORK SHALL COMMENCE PRIOR TO CONTRACTOR RECEMNG A WRITTEN NOTICE TO PROCEED (NIP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE DISH WIRELESS LLC, AND TOWER OWNER NOC do THE DISH WIRELESS L.L.C. AND TOWER OWNER CONSTRUCTION MANAGER. 2. "LOOK UP" -DISH WIRELESS L.L.C. AND TOWER OWNER SAFELY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CUMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL 8E CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION, TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE, THIS SHALL INCLUDE, BUT NOT BE LIMITED TO* PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE, ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR DISH WIRELESS LLC. AND DISH WIRELESS L.L.C. AND TOWER OWNER POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET, 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHAH BE OBTAINED. THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL REQUIREMENTS. 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED T0, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND DISH WIRELESS L.I.E.C. AND TOWER OWNER STANDARDS, INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). 5. ALL SITE WORK TO COMPLY WITH DISH WIRELESS LLC. AND TOWER OWNER INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON DISH WIRELESS L.L.C. AND TOWER OWNER TOWER SITE AND LATEST VERSION OF ANSI/TIA-1019-A-2012 "STANDARD FOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY DISH WIRELESS L.L.C. AND TOWER OWNER PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. THE CONTRACTOR SHALT. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES INCLUDING PRIVATE LOCATES SERVICES PRIOR TO THE START OF CONSTRUCTION, 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES, CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW, THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY PROCEDURES, 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND DISH PROJECT SPECIFICATIONS, LATEST APPROVED REVISION. 12, CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF DISH WIRELESS L.L,C. AND TOWER OWNER, AND/OR LOCAL UTILITIES. 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS AND RADIOS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. GENERAL NOTES: 1.FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR:GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER:DISH WIRELESS LLC. TOWER OWNER:TOWER OWNER 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE, AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY. 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS, WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN, IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 6. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CARRIER POC AND TOWER OWNER. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND TOWER OWNER PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION, BEFORE SUBMITTING BIDS, TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF DISH WIRELESS LLC, AND TOWER OWNER 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. .sh Wksimm 5701 SOUTH SANTA FE DRIVE uTrLETON, CO 80120 Jacob& Challenging today. Reinventing tomorrow. Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 N ce ce HsR�OCF No. 91030`; A STATE OF !q 66400 '''FSS/ONAl6�G`o�• THi5ITE1.1 HAS BEEN ELECTRONICALLY SIO&D AMID SEALED BY STEPHEIt C. RIDGE USNIG A DIGITAL SIGNATURE P110 DATE. PRINTED COPIES OF THIS DOCUTAENT ARE NOT CONSIDERED 5lCUED ANO SEALEO AND THE SIGNATURE 1{UST BE VERIFIED ON AIN ELECTRONIC COPIES R IS A VIOLATION OF LAW FOR APERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A DCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT, DRAWN BY: CHECKED BY: APPROVED BY: CRO WBP KRK REDS REV: TBD No CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 0!/2J/202I ISSUED FOR CONSTRICTION A&E PROJECT NUMBER EUCCO309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE GENERAL NOTES SHEET NUMBER GN=2 CONCRETE. FOUNDATIONS. AND REINFORCING STEEL: 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE. 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 psf. 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90'f AT TIME OF PLACEMENT. 4. CONCRETE EXPOSED TO FREEZE -THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES, AMOUNT OF AIR ENTRAINMENT TO BE BASED ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A MAXIMUM WATER -TO -CEMENT RATIO (W/C) OF 0.45. 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A815. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. ALL SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, UNLESS NOTED OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: �4 BARS AND SMALLER 40 ksi #5 BARS AND LARGER 60 kei 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: • CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" • CONCRETE EXPOSED TO EARTH OR WEATHER: • #6 BARS AND LARGER 2" • #5 BARS AND SMALLER 1-1/2' • CONCRETE NOT EXPOSED TO EARTH OR WEATHER: • SLAB AND WALLS 3/4" • BEAMS AND COLUMNS 1-1/2" 7. A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. ELECTRICAL INSTALLATION NOTES: 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES/ORDINANCES, 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1, ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACIiY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. Be TIE WRAPS ARE NOT ALLOWED. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (ff6 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-21 THIN, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR, TYPE SOOW CORD (#14 OR LARGER) UNLESS OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR, TYPE TC CABLE (#14 OR LARGER), WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75' C (90' C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUfi (IMC), OR RIGID METAL CONDUR (RMC) SHALL 8E USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS, 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT, 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID -TITS FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE NEC. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS, EXPLOSIVE DEVICES (i.e. POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3 (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA i (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (COP OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR DISH WIRELESS L.L.C. AND TOWER OWNER BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES ANO STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "DISH WIRELESS L.L.C.'. 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. .sh 5701 SOUTH SANTA FE DRIVE uTTLETON, CO 80120 Jacob& Challenging today. Reinventing tomorrow. Jacobs Teleconnnunicatlons, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 Om NID1of ��QNEN. Co R/0' //// ENS 0 No, 91030 A. a * e STATE OF I . •:`<0R10 F+'��Kv °%FSS%ONAIE�q �//I,IIlilllLll\\, THIS 1TE1.1 HAS BEE„ ELECTRONICALLY SIGHED AND SEALED BY STEPHEN C. RIDGE USM A DIGITAL SIGNATURE N!D DATE PRINLED COPIES OF THIS DOCUMENT ARE NOT CalLDEREO SIGNED AND SEALED AND THE SIGNATURE RW ST BE \VERIFIED ON NIY ELECTRONIC COPIES R IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY RE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT, DRAWN BY: CHECKED BY: 1APPROVED BY: CRO WBP momm KIRK RFDS REV #: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 0!/25/2021 ISSUED TOR CONSTRUCTION A&E PROJECT NUMBER EUCCO309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE GENERAL NOTES SHEET NUMBER GN-3 GROUNDING NOTES: 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 2. THE CONTRACTOR SHALL PERFORM IEEE FALL —OF —POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT, 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 100 USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS, 14, ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 154 APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 160 ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON —ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 180 BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. 190 GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS, WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON—METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON—METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD —WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK, (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). DO NOT ATTACH GROUNDING TO FIRE SPRINKLER SYSTEM PIPES. s h 5701 SOUTH SAWA FE DRIVE uTTLETON, CO 80120 Jacobs Challenging today. Reinventing tomorrow. Jacobs Telecommunications, Inc. 5449 BELLS FERRY ROAD ACWORTH, GA 30102 \\11111 illlll/ CENSf..% p� �. * No. 91030 STATE OF I lfltONAIV N111111mi" THIS 1iElA HAS HEN ELECTRONICALLY SIGNED MID SFALEO BV STEPHEN C. RIDGE USRV3 A DIGITAL SIG?IATURE Nm DATE. PRIMED COMES OF n11S DOCU,, RIC ARE IMT CON4DERED SIGNED AND SEALED AND THE SIGNATURE \W ST BE \EFIRED ON NN ELECTRONIC COPIES R IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS 1HEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT, DRAWN BY: CHECKED BY: 1APPROVED BY: CRO WBP KIRK RFOS REV #: TBD CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A OE/27/2021 ISSM FOR CONSTRUCTION A&E PROJECT NUMBER EUCC0309 DISH WIRELESS L.L.C. PROJECT INFORMATION ORMC000169A 1126 E. SR 434 WINTER SPRINGS, FL 32708 SHEET TITLE GENERAL NOTES SHEET NUMBER GN-4