HomeMy WebLinkAbout503 - Newberg Winter Springs Blvd Price QuotationProposal shall remain valid for a 30 day period from published date hereon
3336 36TH.AVE N. ST. PETERSBURG, FL 33713
ST. PETERSBURG (727) 521-6620 FAX (727) 521-0230
Web Site www.irrigationnet.com
DATE: 10-16-2019
PROJECT: WINTER SPRINGS BOULEVARD
2-WIRE RE-GROUNDING &
SPLICING
PLANS DATED: N/A SPECIFICATIONS:
SHEETS: ADDENDA NOTED: #
DESIGNED BY: SCALE:
Newberg Irrigation, Inc. proposes to provide all materials, labor, and equipment necessary to install the irrigation
system for the project referenced above. The products will be as specified and/or detailed in the approved plans.
IRRIGATION SYSTEM PROPOSAL ………………………………………………………………
$ 35,810.00
NOTES INCLUDES:
LOCATE EXISTING 2-WIRE PATH, DECODERS, CONTROL VALVES & SPLICE BOXES.
NEW GROUNDING EVERY 1000’ OR LESS ALONG THE 2-WIRE PATH LOCATED ON
THE NORTH SIDE OF WINTER SPRINGS BLVD WITH HUNTER INLINE SURGE
SUPPRESSORS & ANY DEAD-END WIRE PATH DECODER ALL WITH COPPER GLAD
GROUND RODS, 6 AWG BARE COPPER WIRE & CLAMPS OR CAD-WELD.
REPLACING ALL EXISTING DECODER SPLICES & CONTROL VALVE SPLICES.
NOTES ALL DECODERS TO BE EXISTING (ICD-100, 200, 400 OR 600 SERIES)
NOTES IT IS ASSUMED ALL EXISTING 2-WIRE IS INSTALLED IN EXISTING CONDUIT.
ALL GROUNDING TO MANUFACURES SPECIFICATIONS.
Sleeves not included. Price based on plans dated 2-9-10 IR-1 Thru ID-13
Redline As-Built not provided.
All Inline Surge Suppressors and Ground Rods to be Installed in New Boxes. All Splice Kits to be 3M DBRY-6.
Main Line not included.
Lateral piping not included.
ALL Electrical distribution & connections, 120 V or higher, by OTHERS. Irrigation Contractor will only coordinate
connections to controllers, at plan locations, to existing fused power supplies.
All Taps, Backflows, Master Valves, Cla-Val, Meters, Reuse Meters & Meter Assembly Devices by Others.
Landscape, Hardscape and Sod repairs by OTHERS.
2-Wire Decoder Cable to be Existing. Installation of New 2-Wire will be at an Additional cost.
No Core Drilling performed.
No Jack & Bore or Cut & Patch included.
No Traffic Control Provided.
No ROW Permit provided.
ALL other Permits by OTHERS.
Layout & Survey by OTHERS.
Landscape Architect/Landscape Contractor shall be responsible for the layout of ALL landscape beds, prior to irrigation
system layout, to facilitate installation.
Price Quotation
Proposal shall remain valid for a 30 day period from published date hereon
Thank you for the opportunity to submit this proposal.
H. Joel Newberg
joel_newberg@irrigationnet.com