HomeMy WebLinkAbout2019 05 23 Planning and Zoning Board/LPA Special Meeting AgendaPLANNING AND ZONING BOARD/LOCAL PLANNING AGENCY
SPECIAL MEETING | THURSDAY, MAY 23, 2019 | PAGE 1 OF 2
PLANNING AND ZONING BOARD/
LOCAL PLANNING AGENCY
SPECIAL MEETING AGENDA
THURSDAY, MAY 23, 2019 AT 5:30 PM
CITY HALL - COMMISSION CHAMBERS
1126 EAST STATE ROAD 434, WINTER SPRINGS, FLORIDA
CALL TO ORDER
Roll Call
Invocation
Pledge of Allegiance
Approval of the Agenda
AWARDS AND PRESENTATIONS
100.Not Used
INFORMATIONAL AGENDA
200.Not Used
PUBLIC INPUT
Anyone who wishes to speak during Public Input on any Agenda Item or subject matter will need to fill out a
“Public Input” form. Individuals will limit their comments to three (3) minutes, and representatives of groups
or homeowners' associations shall limit their comments to five (5) minutes, unless otherwise determined by
the City Commission.
CONSENT AGENDA
300.Not Used
PUBLIC HEARINGS AGENDA
400. Ocean Bleu Retail Building Final Engineering, Aesthetic Review, and
Special Exceptions
Attachments: Final Engineering
Aesthetic Review
Special Exception Application
PLANNING AND ZONING BOARD/LOCAL PLANNING AGENCY
SPECIAL MEETING | THURSDAY, MAY 23, 2019 | PAGE 2 OF 2
401.West End Professional Center Monument Sign Special Exception
Attachments: Elevation
Site Plan
Photograph
REGULAR AGENDA
500. Not Used
REPORTS
PUBLIC INPUT
Anyone who wishes to speak during Public Input on any Agenda Item or subject matter will need to fill out a
“Public Input” form. Individuals will limit their comments to three (3) minutes, and representatives of groups
or homeowners' associations shall limit their comments to five (5) minutes, unless otherwise determined by
the City Commission.
ADJOURNMENT
PUBLIC NOTICE
This is a Public Meeting, and the public is invited to attend and this Agenda is subject to change.
Please be advised that one (1) or more Members of any of the City's Advisory Boards and Committees
may be in attendance at this Meeting, and may participate in discussions.
Persons with disabilities needing assistance to participate in any of these proceedings should
contact the City of Winter Springs at (407) 327-1800 "at least 48 hours prior to meeting, a written
request by a physically handicapped person to attend the meeting, directed to the chairperson or
director of such board, commission, agency, or authority" - per Section 286.26 Florida Statutes.
“If a person decides to appeal any decision made by the board, agency, or commission with respect
to any matter considered at such meeting or hearing, he or she will need a record of the
proceedings, and that, for such purpose, he or she may need to ensure that a verbatim record of
the proceedings is made, which record includes the testimony and evidence upon which the appeal
is to be based” - per Section 286.0105 Florida Statutes.
Special Exception Application
TITLE
Ocean Bleu Retail Building Final Engineering, Aesthetics, and Special Exceptions
SUMMARY
APPLICANT AND PROPERTY INFORMATION:
• Applicant/Property owner’s name(s): JDBS Winter Springs, LLC
• Property addresses: 201 Michael Blake Boulevard
• Property Parcel ID numbers: 26-20-30-5AR-0A00-008M
• Current FLUM Designation: Town Center District
• Current Zoning Designations: T-C (Town Center District)
• Development Agreements (if any): Winter Springs Holdings, 4/9/15
First Modification, 1/9/17
• Pending Code Enforcement Actions (if any): None
• City Liens (if any): None
APPLICABLE LAW, PUBLIC POLICY, AND EVENTS:
Home Rule Powers
Winter Springs Code of Ordinances
City of Winter Springs Comprehensive Plan
Project Overview
JDBS Winter Springs, LLC (The Ocean Bleu Group) is proposing to build a multi-
tenant retail building in the Winter Springs Town Center. The proposed 7,200 square
foot two-story building is located on a 0.83-acre parcel on the north side of S.R. 434,
east of Tuskawilla Road, west of Michael Blake Boulevard, and directly in front of The Blake Apartments (Catalyst) currently in the last phases of construction. The Ocean
Bleu retail project will offer 51 parking spaces, bicycle parking, enhanced pedestrian
access facilities, and a highly decorative aesthetic design package for both the
building and surrounding site improvements.
PUBLIC HEARINGS AGENDA ITEM 4 0 0
PLANNING AND ZONING BOARD/LOCAL PLANNING AGENCY
MAY 23, 2019 | REGULAR MEETING
PUBLIC HEARINGS AGENDA ITEM 400 | THURSDAY, MAY 2 3 , 2019 | PAGE 2 OF 5
Aesthetic Review Plans (Exhibit A attached)
The proposed project consists of one two-story multi-tenant retail building (faux second-story). The building uses a combination of stucco, brick, and cultured stone
veneers. The building utilizes a neutral color scheme and various yet highly
compatible materials that serves as an aesthetic bridge between the Starbucks and
the Blake.
The front of the building faces S.R. 434, and will feature wide sidewalks with the
potential for outdoor seating. As a multi-tenant building, details of signage and
precise locations of main entrances will depend on the number, location, and square
footage of future tenants.
The proposed project is designed to contribute significantly to the quality
architectural styles that are typical of the Winter Springs Town Center and the
surrounding area. The proposed building represents a positive addition to the City
of Winter Springs, and is a high-quality, unique design that is harmonious with its
surroundings and will add value to the proposed location
Final Engineering Plans
The Ocean Bleu Retail Building is a proposed multi-tenant retail building with a faux
second story. The plans depict one 7,200 square foot building on a 0.83 acre lot,
which is owned by JDBS Winter Springs LLC. A parking lot is located on the north
and west sides of the building. The parking lot contains 48 standard parking stalls
and three handicap stalls. The site also includes a bike rack for multi-modal customers. Access to and from the site is through two driveway connections on Sea
Hawk Cove. The western access is a shared driveway with the existing Starbucks. Sea
Hawk Cove was recently completed as part of The Blake Apartments project, by
Catalyst. Sea Hawk Cove can be accessed from Michael Blake Blvd or Eagle Edge
Lane, which was also recently completed with The Blake Apartments project.
The site includes a parking area, paver patio area, enhanced landscaping, lighting,
and upgraded sidewalks. The enhanced landscaping and 12-ft sidewalks will be
located along SR 434 to provide a more walkable and aesthetically pleasing
frontage. The project will also include the construction of additional parallel parking stalls on the south side of Sea Hawk Cove.
Sea Hawk Cove and The Blake Apartments will border the site to the north.
Starbucks will border the site to the west. The east and south sides of the site will be
bordered by Michael Blake Blvd and SR 434, respectively.
The site’s stormwater is master planned into The Blake Apartments’ master
stormwater pond, which is located east of the Cross Seminole Trail. No additional
onsite stormwater treatment is required. Existing infrastructure will route
stormwater to the master pond. The facility will connect to Winter Springs water and
sewer facilities located along Sea Hawk Cove. The City has water and sewer plant
capacity to service this project.
PUBLIC HEARINGS AGENDA ITEM 400 | THURSDAY, MAY 2 3 , 2019 | PAGE 3 OF 5
Special Exceptions
The applicant is requesting approval of five Special Exception requests. In granting a Special Exception, per the Town Center Code, the City Commission must find
substantial competent evidence that:
(1)The city commission may by special exception waive strict compliance with provisions of
this code in furtherance of promoting the town center policies adopted by the city. In
granting a special exception, the city commission must find by substantial competent
evidence that:
(a)The proposed to development contributes, promotes and encourages the
improvement of the Winter Springs Town Center and catalyzes other development
as envisioned in the Winter Springs Town Center regulations.
The proposed development will add 7 retail units to the prominent corner of
SR434 and Michael Blake Boulevard which is consistent with the mixed use
nature of the overall Town Center.
(b)The proposed development will not have an unfavorable effect on the economy of
the Winter Springs Town Center and complies with the economic fiscal impact
requirements set forth in the City's Comprehensive Plan and Code.
The development of retail units in the proposed development will have a
positive impact on the economy of the Winter Springs Town Center by locating
shopping areas directly adjacent to local consumers in the Town Center who will
be shopping and dining locally and generating more demand for local business.
(c)The proposed development abides by all rules in this code other than those
specially excepted. Special limitations apply to large footprint buildings (greater than
twenty thousand (20,000) square feet); see subsection 20-324(9) for these limitations.
The proposed development will abide by all rules in the code other than those
being requested in this Special Exception application. The proposed
development does not proposed any building with footprints larger than 20,000
square feet.
(d)The proposed development meets any reasonable additional conditions,
restrictions or limitations deemed necessary by the city commission in order to
preserve and promote the intent of the Winter Springs Town Center District Code.
If the City Commission proposes any reasonable additional conditions,
restrictions, or limitations, the Developer will strive to meet them.
20-321(c} Town Center Special Exceptions
PUBLIC HEARINGS AGENDA ITEM 400 | THURSDAY, MAY 2 3 , 2019 | PAGE 4 OF 5
(e) With respect to each waiver requested, the specific waiver shall comply with all
of the following:
(i) Is a result of special conditions and circumstances which are peculiar
to the land, site plan, structure or building involved and which justify
granting the waiver in the context of the overall proposed
development being successful within the town center;
(ii) Is the minimum waiver from the town center regulations necessary to
make possible the reasonable use of the land, building or structure;
(iii) Is in harmony with the general intent and purpose of the town center
regulations;
(iv) Will not be injurious or incompatible to the town center and any
surrounding neighborhood or property; and
(v) Will not create a public nuisance or be detrimental to the public health,
safety, and welfare relative to public services including water, sewer,
surface water management, police, fire, parks and recreation, streets
and traffic patterns, public transportation, marina and water ways,
bicycle and pedestrian facilities.
The applicant requests that the Planning and Zoning Board consider the five
following Special Exception requests:
Special Exception Request #1:
The applicant requests a Special Exception to increase the front setback from SR 434 from the maximum of 8-feet to approximately 47-feet.
Sec. 20-325. - Transect standards.
T5 (Urban Center Zone)
Principle building setbacks (from property line) Front/principle plane- 0 ft.—8 ft. max (from front property line)
Staff supports this Special Exception based on the inclusion of a decorative knee wall
with landscaping along the west side of the property. This setback Special Exception
maintains the setback plane of Starbucks and the retail buildings west of Tuskawilla.
Special Exception Request #2: The applicant requests a Special Exception to reduce the off-street parking lot
setback from S.R. 434 from a required minimum setback of 50-feet to approximately
40-feet.
Sec. 20-324. - General provisions.
8c. Off-street surface parking lot placement. Off-street surface parking lots shall be
set back a minimum of fifty (50) feet from the property line along the main street
to accommodate liner buildings.
PUBLIC HEARINGS AGENDA ITEM 400 | THURSDAY, MAY 2 3 , 2019 | PAGE 5 OF 5
Staff supports this Special Exception based on the relatively small size and location
of the off-street parking lot, the small size of the property, plus the inclusion of a decorative knee wall and landscaping along the S.R. 434 frontage to provide
adequate screening of the off-street parking lot.
Special Exception Request #3:
The applicant requests a Special Exception to reduce the 80% frontage buildout at
the front setback required in the T5 transect to approximately 60%.
Sec. 20-325. - Transect standards.
T5 (Urban Center Zone)
Lot Design Guidelines- 80% min. (at front setback)
Staff supports this Special Exception based on the recognition that it would be
highly impractical for a relatively small retail building on a 0.83-acre lot to achieve
an 80% frontage buildout at the front setback, while still providing adequate
parking, access, landscaping, and pedestrian facilities. To offset the frontage
buildout reduction, the site includes a decorative knee wall, landscaping, and a new
12-foot wide sidewalk along the S.R. 434 frontage.
Special Exception Request #4:
The applicant requests a parking setback of 24’ from the property line along the
main street, which is less than the 50’ minimum required.
Sec. 20-324.(8) - General provisions
T5 (Urban Center Zone)
Parking
Staff supports this Special Exception on aesthetic and circulation grounds. Special Exception requests 4 and 5 are meant to match the adjoining parking sections of
this retail project and the adjacent Starbucks.
Special Exception Request #5:
The applicant requests a waiver for the requirement of a 6’ landscape island
separating more than 6 consecutive parking spaces.
Sec. 20-324.(8) - General provisions
T5 (Urban Center Zone)
Parking
Staff supports this Special Exception on aesthetic and circulation grounds. Special
Exception requests 4 and 5 are meant to match the adjoining parking sections of
this retail project and the adjacent Starbucks.
RECOMMENDATION
Staff recommends approval of the Final Engineering, Aesthetic Review, and all
Special Exceptions.
NO.
MICHAEL BLAKE BLVD & E STATE RD 434
WINTER SPRINGS, FLORIDA
AT
WSTC LOT 4 RETAIL
ENGINEERDEVELOPMENT MANAGER / APPLICANT
JDBS WINTER SPRINGS, LLC
10931 N. DALE MABRY HWY
TAMPA, FL 33618
BRYAN SCHULTZ
(813)28804654
NV5, INC.
201 S. BUMBY AVENUE
ORLANDO, FLORIDA 32803
FRANKLIN A. PORTER, P.E.
407-896-3317
AERIAL PHOTOVICINITY MAP
NTS
COVER SHEET
C6.0
C1.0
SITE PLAN
C10.0
C3.0
SWPPP PHASE 1 PLAN
C4.0
SWPPP PHASE 2 PLAN
S1.0
C5.0
WATER DETAILS
DESCRIPTION
PLANS
BOUNDARY AND TOPOGRAPHIC SURVEY
SANITARY SEWER DETAILS
PROJECT
LOCATION
C9.0
CONSULTANTS
LANDSCAPE:
GEOTECH:
407-859-8378
ORLANDO, FL 32809
2815 DIRECTORS ROW, SUITE 500
ECS FLORIDA, LLC
407-695-4800
MAITLAND, FLORIDA 32751
601 S. LAKE DESTINY RD, SUITE 200
WATER MANAGEMENT:
SITEWORK CONSTRUCTION
JURISDICTION / UTILITIES
WATER
WINTER SPRINGS, FLORIDA 32708
1126 EAST STATE ROAD 434
CITY OF WINTER SPRINGS, FLORIDA
ST. JOHNS RIVER WATER MAN. DISTRICT
WASTEWATER
ELECTRIC:
OVIEDO, FLORIDA 32765
2801 WEST STATE ROAD 426
DUKE ENERGY
800-700-8744
TELEPHONE:
ORLANDO, FLORIDA 32801
AT&T
407-351-8190
CABLE:
ORLANDO, FLORIDA 32810
3767 ALL AMERICAN BLVD.
SPECTRUM CABLE
1-800-222-0102
SURVEYOR:
407-896-3317
FRANK A. PORTER, P.E.
ORLANDO, FLORIDA 32803
201 SOUTH BUMBY AVENUE
LOCHRANE ENGINEERING, INC.
CIVIL ENGINEER:
ARCHITECT:
ROBERT M. HOGUE
BHM ARCHITECTURE, INC.
407-333-2005
LEGAL DESCRIPTION
GRADING PLAN
GENERAL DETAIL SHEET 1
J.SCOTT LIBERTY
WINTER PARK, FLORIDA 32792
5621 REVELWOOD LOOP
LANDSCAPE ARCHITECT LLC
407-719-2124
PROJECT
LOCATION
407-896-3317
CHRIS LABERG, P.E.
ORLANDO, FLORIDA 32803
201 SOUTH BUMBY AVENUE
LOCHRANE ENGINEERING, INC.
WINTER SPRINGS, FLORIDA 32708
1126 EAST STATE ROAD 434
CITY OF WINTER SPRINGS, FLORIDA
407-327-8979
WINTER SPRINGS, FLORIDA 32708
1126 EAST STATE ROAD 434
CITY OF WINTER SPRINGS, FLORIDA
GENERAL DETAIL SHEET 2
C2.0
C7.0
OWNER
JDBS WINTER SPRINGS, LLC
10931 N. DALE MABRY HWY
TAMPA, FL 33618
C8.0
GEOTECHNICAL DATA:
EARTHWORK RELATED TO THE BUILDING FLOOR SLAB SHALL BE PERFORMED IN ACCORDANCE WITH THE
RECOMMENDATIONS PROVIDED IN THE GEOTECHNICAL REPORT BY ECS FLORIDA, LLC, REPORT JOB NO.
24-6014, SIGNED BY ARAVIND RANGASWAMY, PE ON MARCH 8, 2017.
CONTRACTOR IS RESPONSIBLE FOR OBTAINING A COPY OF THIS REPORT.
UTILITY PLAN
L1.0 LANDSCAPE PLAN
LI1.0 IRRIGATION PLAN
407-327-8979
407-327-8979
BRYANT SMITH, P.E.
BRYANT SMITH, P.E.
BRYANT SMITH, P.E.
PARCEL ID #: 06-21-31-506-0000-0040
FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Mar. 14, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065COVER SHEETC1.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUPSITE PLAN NOTES:
1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY OF WINTER
SPRINGS REGULATIONS AND CODES AND O.S.H.A. STANDARDS.
2. CONTRACTORS MUST BE FDOT PREQUALIFIED IN THE WORK CLASSES OF GRADING,
DRAINAGE, AND FLEXIBLE PAVING TO BE ELIGIBLE TO WORK WITHIN THE PUBLIC ROW OF
THIS PROJECT. THE PAVING SUBCONTRACTOR, IF APPLICABLE, MUST ALSO BE FDOT
PREQUALIFIED IN FLEXIBLE PAVING.
3. ALL DISTURBED AREAS ARE TO RECEIVE FOUR INCHES OF TOPSOIL, SEED,
MULCH AND WATER UNTIL A HEALTHY STAND OF GRASS IS ESTABLISHED.
SEE 02900 SPECIFICATION.
4. ALL ISLANDS WITH CURB & GUTTER SHALL BE LANDSCAPED, UNLESS
OTHERWISE NOTED. THOSE ISLANDS ARE TO HAVE CONC. CURB.
5. ALL DIMENSIONS AND RADII ARE TO THE FACE OF CURB UNLESS
OTHERWISE NOTED.
6. EXISTING STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE MODIFIED
AS NECESSARY. ALL COST SHALL BE INCLUDED IN BASE BID.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RELOCATIONS, (UNLESS
OTHERWISE NOTED ON PLANS) INCLUDING BUT NOT LIMITED TO, ALL
UTILITIES, STORM DRAINAGE, SIGNS, TRAFFIC SIGNALS & POLES, ETC. AS
REQUIRED. ALL WORK SHALL BE IN ACCORDANCE WITH GOVERNING
AUTHORITIES REQUIREMENTS AND PROJECT SITE WORK SPECIFICATIONS
AND SHALL BE APPROVED BY SUCH. ALL COST SHALL BE INCLUDED IN BASE
BID.
8. THE SITE WORK FOR THE PROJECT SHALL MEET OR EXCEED THE "SITE
SPECIFIC SPECIFICATIONS".
9. LIGHTING ELECTRICAL PLANS TO BE PROVIDED BY DUKE ENERGY. ALL SITE LIGHTING IS TO
BE INSTALLED PRIOR TO SITE ACCEPTANCE. CITY APPROVAL OF
THE DUKE STREET LIGHTING PLAN IS REQUIRED PRIOR TO FINALIZATION. POLES AND
FIXTURES ARE REQUIRED TO BE DECORATIVE
10. ALL SIGNAGE AND STRIPING TO BE INSTALLED IN ACCORDANCE WITH
MUTCD (LATEST EDITION) STANDARDS AND SPECIFICATIONS. ALL SIGNAGE IS TO BE
DECORATIVE. ALL STRIPING TO BE THEREMOPLASTIC.
11. ALL CONSTRUCTION DUMPSTERS TO BE WASTE PRO, NO EXCEPTIONS. DUMPSTERS ARE TO
BE LOCATED A MIN. OF 100' FROM ANY SITE BOUNDARY.
12. NO ONSITE BURNING IS ALLOWED AT ANY TIME.
13. ALL ORGANIC OR OTHER UNSUITABLE MATERIALS MUST BE HAULED OFF
THE SITE AND PROPERLY DISPOSED.
14. PAYMENT OF THE 1% SITE INSPECTION FEE IS DUE PRIOR TO BREAKING
GROUND. FEE IS 1% OF THE TOTAL SITEWORK CONSTRUCTION COST, NOT
INCLUDING ITEMS COVERED BY A BUILDING PERMIT.
15. PROVIDE A VIDEO INSPECTION OF ALL SANITARY SEWER MAINS, SANITARY
SEWER LATERALS, AND ALL STORMWATER PIPES. PROVIDE THE CITY WITH
A DVD COPY OF ALL VIDEO INSPECTIONS.
16. ALL WORK PERFORMED WITHIN THE FDOT RIGHT-OF-WAY (S.R. 434) SHALL BE IN
ACCORDANCE WITH 2017 DESIGN STANDARDS, 2017 STANDARD
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, AND 2010 UTILITY
ACCOMODATION MANUAL.
17. A 6' CHAIN LINK FENCE WITH EITHER GREEN OR BLACK OPAQUE PRIVACY SCREEN IS
REQUIRED TO BE INSTALLED AROUND THE PROJECT PERIMETER PRIOR TO SITE WORK AND MAINTAINED
THROUGHOUT THE DURATION OF THE PROJECT.
18. A REFUNDABLE STORMWATER POLLUTION PREVENTION PLAN CASH DEPOSIT OR LETTER
OF CREDIT FOR THE LESSER OF 1% OF THE SITE CONSTRUCTION COST OR $5,000 IS
REQUIRED AT THE PRE-CONSTRUCTION MEETING
1. CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES SERVING THE STRUCTURE.
2. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING
UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND
WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS
BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST
72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE
PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
3. ALL CUT OR FILL SLOPES SHALL BE 4:1 OR FLATTER UNLESS OTHERWISE NOTED.
4. PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
5. EXISTING AND NEWLY INSTALLED PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
6. STORM PIPE SHALL BE PER MASTER SITE SPECIFICATIONS SECTION 02630 (ADS HP STORM OR EQUIVALENT)
7. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO
RETURN IT TO EXISTING CONDITIONS OR BETTER.
8. ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS
WATERTIGHT
9. ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE
TRAFFIC BEARING RING & COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISH GRADE. LIDS
SHALL BE LABELED "STORM SEWER".
10. THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE GENERAL N.P.D.E.S.
PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES.
11. CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT
AND CONTINUOUS GRADE.
12. CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED
13. ALL UNSURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL.
CONTRACTOR SHALL APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL
STABILIZE DISTURBED AREAS IN ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND
OF VEGETATION IS OBTAINED.
14. CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODES AND BE CONSTRUCTED TO SAME.
15. ALL STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT OUT.
16. TOPOGRAPHIC INFORMATION IS TAKEN FROM A TOPOGRAPHIC SURVEY BY LAND SURVEYOR CONSULTANT. IF THE CONTRACTOR
DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE CONTRACTOR
SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE OWNER
FOR REVIEW.
17. ALL EXISTING MANHOLE RIMS TO BE FLUSH WITH FINISHED GRADE. CONTRACTOR TO INSTALL MANHOLE RISERS OR
ADJUST EXISTING FRAMES AS NECESSARY.
18. EXISTING GRATE ELEVATIONS TO REMAIN. WHERE PAVEMENT OVERLAY IS TO BE PLACED, FEATHER OVERLAY TO
MATCH EXISTING GRATE ELEVATION TO FORM A SMOOTH TRANSITION.
19. SPOT ELEVATIONS ADJACENT TO CURBS REPRESENT EDGE OF PAVEMENT ELEVATIONS, TOP OF CURB SHOULD BE CONSIDERED 6" HIGHER.
20. CONTRACTOR TO MATCH EXISTING GRADE AT LIMITS OF DISTURBANCE, AS DEPICTED ON SWPPP SITE MAPS
21. STRIP THE SURFICIAL ORGANIC SANDS AND IMPORT A MINIMUM OF 2 FEET OF PRE-APPROVED ENGINEERED FILL
WITHIN THE LIMITS OF PROPOSED BUILDING FOUNDATIONS AND PAVEMENT.
22. AFTER STRIPPING IS COMPLETE, THE EXPOSED SUBGRADE SHALL BE OBSERVED, TESTED AND PROOF-ROLLED WITH
A MINIMUM OF 10 PASSES WITH A HEAVY VIBRATORY ROLLER IN PERPENDICULAR DIRECTIONS.
23. FILL SHALL BE COMPACTED IN LIFTS NO THICKER THAN 9 TO 12 INCHES IN LOOSE THICKNESS, WITH EACH LIFT COMPACTED
TO AT LEAST 95 PERCENT OF THE SOILS MODIFIED PROCTOR DRY DENSITY, (ASTM D-1557), AT A DEPTH OF 1 FOOT BELOW
THE COMPACTED SURFACE, AS DETERMINED BY IN-PLACE DENSITY TESTS.
24. FILL SHALL BE COMPACTED TO 95 PERCENT OF THE MATERIAL'S MAXIMUM MODIFIED PROCTOR DRY DENSITY
25. IMPORTED FILL OR BACKFILL SHOULD CONSIST OF FINE SAND WITH LESS THAN 15 PERCENT PASSING THE NO. 200 SIEVE, FREE
26. MOISTURE CONTENT OF THE FILL SHALL BE WITH IN +/-2 PERCENT OF OPTIMUM MOISTURE CONTENT AS
ESTABLISHED IN ASTM D-1557.
27. ONE FIELD DENSITY TEST SHALL BE CONDUCTED PER 2,500 SQUARE FEET (OR FRACTION THEREOF) PER LIFT, IN THE BUILDING AREA,
28. ALTHOUGH THE EXPOSED SUBGRADE IS ANTICIPATED TO BE RELATIVELY STABLE UPON INITIAL EXPOSURE,
UNSTABLE SUBGRADE CONDITIONS COULD DEVELOP DURING GENERAL CONSTRUCTION OPERATIONS IF THE SOILS ARE
WETTED AND/OR SUBJECTED TO REPETITIVE CONSTRUCTION TRAFFIC.
SITE GRADING NOTES:
SITE UTILITY NOTES:
1. ALL FILL MATERIAL IS TO BE IN PLACE, AND COMPACTED BEFORE INSTALLATION OF
PROPOSED UTILITIES.
2. CONTRACTOR SHALL NOTIFY THE PROPER UTILITIES AUTHORITIES 48 HOURS PRIOR TO ANY
UTILITIES CONSTRUCTION.
3. SANITARY SEWER GRAVITY PIPE SHALL BE AS FOLLOWS:
- 8" PVC SDR35 PER ASTM D 3034, FOR PIPES LESS THAN 10' DEEP
- 8" PVC SDR26 PER ASTM D 3034, FOR PIPES MORE THAN 10' DEEP
- 6" PVC SDR 35 PER ASTM D3034
4. WATER LINES SHALL BE AS FOLLOWS, UNLESS OTHERWISE DEPICTED ON PLANS:
- 3" AND SMALLER, PVC ASTM D 221, WITH SDR 21 RATING, CONTINUALLY MARKED WITH
MFR'S NAME PIPE SIZE, CELL CLASSIFICATION, SDR RATING, AND ASTM D1748 MAT. CLASS
- 4" TO 16", PVC, AWWA C900, RATED DR18 (CLASS 150), CONTINUALLY MARKED AS REQ'D
- 4" TO 16", DIP, AWWA C151, PRESSURE CLASS 350 (4-12"), PRESSURE CLASS 250 (14-16")
5. MINIMUM TRENCH WIDTH SHALL BE 2 FEET.
6. CONTRACTOR SHALL MAINTAIN A MINIMUM OF 3'-0" COVER ON ALL WATERLINES AND
SANITARY SEWER.
7. LINES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED BY CITY
OF WINTER SPRINGS PUBLIC WORKS/UTILITIES BEFORE BACKFILLING. CONTRACTOR TO PROVIDE
A MINIMUM 48 HOURS NOTICE.
8. TOPS OF EXISTING MANHOLES SHALL BE RAISED AS NECESSARY TO BE FLUSH WITH
PROPOSED PAVEMENT ELEVATIONS, AND TO BE SIX INCHES ABOVE UNPAVED GROUND
ELEVATIONS WITH WATER TIGHT LIDS.
9. EXISTING UTILITIES HAVE BEEN FIELD VERIFIED, HOWEVER, EXISTING UTILITIES SHALL BE
RE-VERIFIED IN FIELD PRIOR TO INSTALLATION OF ANY NEW LINES. THE EXISTING SANITARY
SEWER SIZE, LOCATION, AND ELEVATION SHALL BE VERIFIED PRIOR TO CONSTRUCTION
AND DEPICTED ON THESE PLANS.
10. REFER TO INTERIOR PLUMBING DRAWINGS FOR TIE-IN OF ALL UTILITIES.
11. ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS REQUIRED BY CODES AND/OR
UTILITY SERVICE COMPANIES SHALL BE PERFORMED PRIOR TO ANNOUNCED BUILDING
POSSESSION AND THE FINAL CONNECTION OF SERVICES.
12. CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION
REQUIREMENTS AND SPECIFICATIONS.
13. ALL WATER JOINTS ARE TO BE MECHANICAL RESTRAINED JOINTS.
14. IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATER LINES, SANITARY LINES, STORM
LINES AND GAS LINES (EXISTING AND PROPOSED), THE SANITARY LINE SHALL BE DUCTILE
IRON PIPE WITH MECHANICAL JOINTS AT LEAST 10 FEET ON BOTH SIDES OF CROSSING, THE
WATER LINE SHALL HAVE MECHANICAL RESTRAINED JOINTS AS REQUIRED TO PROVIDE A
MINIMUM OF 18" CLEARANCE. MEETING REQUIREMENTS OF ANSI A21.10 OR ANSI 21.11 (AWWA
C-151) (CLASS 50).
15. SANITARY LINES 6" AND GREATER ARE TO HAVE A MIN. SLOPE OF 0.40% AND MAINTAIN A MIN
SLOPE OF 2FPS.ALL SANITARY LATERALS (LESS THAN 6" DIAMETER) SHALL BE SLOPED AT A
MINIMUM OF 1.00%.
16. CONTRACTOR SHALL TURN OFF THE CORPORATION STOPS AT THE METERS FOR ALL WATER
SERVICES THAT ARE TO BE REMOVED.
17. WHEN ANY ROOTS OF EXISTING TREES ARE ENCOUNTERED DURING LAND CLEARING
AND/OR GRADING OF THE SITE THE ROOTS MUST BE CUT OFF EVENLY WITH CLEAN SHARP
PRUNING TOOLS. CONTRACTOR SHALL MINIMIZE DAMAGE TO TREE ROOT SYSTEM.
18. A MINIMUM OF 5 FT SEPARATION SHALL BE PROVIDED BETWEEN THE UNDERGROUND
UTILITIES AND ANY PROPOSED LARGE CANOPY TREES.
19. PRIVATE DEDICATED UNDERGROUND FIRE MAINS AND FIRE HYDRANTS MUST BE INSTALLED
BY A LICENSED FIRE CONTRACTOR CLASS I, II, III, IV. COMBINATION FIRE MAINS (SHARED
DOMESTIC AND FIRE PROTECTION SERVICE) AND FIRE HYDRANTS UP TO THE DEDICATED
FIRE PROTECTION SYSTEM "POINT OF SERVICE" CAN BE INSTALLED BY A LICENSED
UNDERGROUND UTILITY/EXCAVATION CONTRACTOR, GENERAL CONTRACTOR, OR PLUMBING
CONTRACTOR.
20. UNDERGROUND FIRE MAINS WILL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH
NFPA 24-2007 EDITION. STANDARDS FOR THE INSTALLATION OF PRIVATE FIRE SERVICE
MAINS AND THEIR APPURTENANCES.
21. IN PAVED AREAS, ALL CLEANOUT COVERS AND VALVE BOXES SHALL BE TRAFFIC RATED AND
FLUSH WOTH TOP OF PAVEMENT.
22. ALL SANITARY MANHOLES SHALL HAVE INCLUDE TROWEL-FINISHED CONCRETE BENCHING.
1 TEST PER 5,000 SQUARE FEET IN PAVEMENT AREAS.
OF RUBBLE, ORGANICS, CLAY, DEBRIS, AND OTHER UNSUITABLE MATERIAL.
29. LANDSCAPED AREAS BETWEEN RESIDENTIAL BUILDINGS AND SIDEWALKS ALONG PUBLIC ROADS SHALL BE SLOPED SUCH THAT THE
EXPOSED FOOTER OF THE BUILDING IS A MINIMUM OF 1 FOOT AND MAXIMUM OF 2.5 FEET.
30. PER TOWN CENTER CODE ALL RESIDENTIAL FINISHED FLOORS MUST BE 2 FEET ABOVE THE ADJACENT SIDEWALK GRADE.
SITEWORK SPECIFICATIONS:
CIVIL ENGINEERING SITEWORK SPECIFICATIONS ARE INTEGRAL TO THIS PLAN SET AND INCLUDED IN THE FINAL PERMIT SET OF
DOCUMENTATION FROM THE CITY OF WINTER SPRINGS. THE CONTRACTOR SHALL OBTAIN A COPY BY CONTACTING NV5.
VERTICAL DATUM:
ALL ELEVATIONS ARE BASED ON NGVD 1929 VERTICAL DATUM
GROUND SURFACES.
NO.
MICHAEL BLAKE BLVD & E STATE RD 434
WINTER SPRINGS, FLORIDA
AT
WSTC LOT 4 RETAIL
ENGINEERDEVELOPMENT MANAGER / APPLICANT
JDBS WINTER SPRINGS, LLC
10931 N. DALE MABRY HWY
TAMPA, FL 33618
BRYAN SCHULTZ
(813)28804654
NV5, INC.
201 S. BUMBY AVENUE
ORLANDO, FLORIDA 32803
FRANKLIN A. PORTER, P.E.
407-896-3317
AERIAL PHOTOVICINITY MAP
NTS
COVER SHEET
C6.0
C1.0
SITE PLAN
C10.0
C3.0
SWPPP PHASE 1 PLAN
C4.0
SWPPP PHASE 2 PLAN
S1.0
C5.0
WATER DETAILS
DESCRIPTION
PLANS
BOUNDARY AND TOPOGRAPHIC SURVEY
SANITARY SEWER DETAILS
PROJECT
LOCATION
C9.0
CONSULTANTS
LANDSCAPE:
GEOTECH:
407-859-8378
ORLANDO, FL 32809
2815 DIRECTORS ROW, SUITE 500
ECS FLORIDA, LLC
407-695-4800
MAITLAND, FLORIDA 32751
601 S. LAKE DESTINY RD, SUITE 200
WATER MANAGEMENT:
SITEWORK CONSTRUCTION
JURISDICTION / UTILITIES
WATER
WINTER SPRINGS, FLORIDA 32708
1126 EAST STATE ROAD 434
CITY OF WINTER SPRINGS, FLORIDA
ST. JOHNS RIVER WATER MAN. DISTRICT
WASTEWATER
ELECTRIC:
OVIEDO, FLORIDA 32765
2801 WEST STATE ROAD 426
DUKE ENERGY
800-700-8744
TELEPHONE:
ORLANDO, FLORIDA 32801
AT&T
407-351-8190
CABLE:
ORLANDO, FLORIDA 32810
3767 ALL AMERICAN BLVD.
SPECTRUM CABLE
1-800-222-0102
SURVEYOR:
407-896-3317
FRANK A. PORTER, P.E.
ORLANDO, FLORIDA 32803
201 SOUTH BUMBY AVENUE
LOCHRANE ENGINEERING, INC.
CIVIL ENGINEER:
ARCHITECT:
ROBERT M. HOGUE
BHM ARCHITECTURE, INC.
407-333-2005
LEGAL DESCRIPTION
GRADING PLAN
GENERAL DETAIL SHEET 1
J. SCOTT LIBERTY
WINTER PARK, FLORIDA 32792
5621 REVELWOOD LOOP
LANDSCAPE ARCHITECT LLC
407-719-2124
PROJECT
LOCATION
407-896-3317
CHRIS LABERG, P.E.
ORLANDO, FLORIDA 32803
201 SOUTH BUMBY AVENUE
LOCHRANE ENGINEERING, INC.
WINTER SPRINGS, FLORIDA 32708
1126 EAST STATE ROAD 434
CITY OF WINTER SPRINGS, FLORIDA
407-327-8979
WINTER SPRINGS, FLORIDA 32708
1126 EAST STATE ROAD 434
CITY OF WINTER SPRINGS, FLORIDA
GENERAL DETAIL SHEET 2
C2.0
C7.0
OWNER
JDBS WINTER SPRINGS, LLC
10931 N. DALE MABRY HWY
TAMPA, FL 33618
C8.0
GEOTECHNICAL DATA:
EARTHWORK RELATED TO THE BUILDING FLOOR SLAB SHALL BE PERFORMED IN ACCORDANCE WITH THE
RECOMMENDATIONS PROVIDED IN THE GEOTECHNICAL REPORT BY ECS FLORIDA, LLC, REPORT JOB NO.
24-6014, SIGNED BY ARAVIND RANGASWAMY, PE ON MARCH 8, 2017.
CONTRACTOR IS RESPONSIBLE FOR OBTAINING A COPY OF THIS REPORT.
UTILITY PLAN
L1.0 LANDSCAPE PLAN
LI1.0 IRRIGATION PLAN
407-327-8979
407-327-8979
BRYANT SMITH, P.E.
BRYANT SMITH, P.E.
BRYANT SMITH, P.E.
PARCEL ID #: 06-21-31-506-0000-0040
FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Mar. 14, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065COVER SHEETC1.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUPSITE PLAN NOTES:
1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY OF WINTER
SPRINGS REGULATIONS AND CODES AND O.S.H.A. STANDARDS.
2. CONTRACTORS MUST BE FDOT PREQUALIFIED IN THE WORK CLASSES OF GRADING,
DRAINAGE, AND FLEXIBLE PAVING TO BE ELIGIBLE TO WORK WITHIN THE PUBLIC ROW OF
THIS PROJECT. THE PAVING SUBCONTRACTOR, IF APPLICABLE, MUST ALSO BE FDOT
PREQUALIFIED IN FLEXIBLE PAVING.
3. ALL DISTURBED AREAS ARE TO RECEIVE FOUR INCHES OF TOPSOIL, SEED,
MULCH AND WATER UNTIL A HEALTHY STAND OF GRASS IS ESTABLISHED.
SEE 02900 SPECIFICATION.
4. ALL ISLANDS WITH CURB & GUTTER SHALL BE LANDSCAPED, UNLESS
OTHERWISE NOTED. THOSE ISLANDS ARE TO HAVE CONC. CURB.
5. ALL DIMENSIONS AND RADII ARE TO THE FACE OF CURB UNLESS
OTHERWISE NOTED.
6. EXISTING STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE MODIFIED
AS NECESSARY. ALL COST SHALL BE INCLUDED IN BASE BID.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RELOCATIONS, (UNLESS
OTHERWISE NOTED ON PLANS) INCLUDING BUT NOT LIMITED TO, ALL
UTILITIES, STORM DRAINAGE, SIGNS, TRAFFIC SIGNALS & POLES, ETC. AS
REQUIRED. ALL WORK SHALL BE IN ACCORDANCE WITH GOVERNING
AUTHORITIES REQUIREMENTS AND PROJECT SITE WORK SPECIFICATIONS
AND SHALL BE APPROVED BY SUCH. ALL COST SHALL BE INCLUDED IN BASE
BID.
8. THE SITE WORK FOR THE PROJECT SHALL MEET OR EXCEED THE "SITE
SPECIFIC SPECIFICATIONS".
9. LIGHTING ELECTRICAL PLANS TO BE PROVIDED BY DUKE ENERGY. ALL SITE LIGHTING IS TO
BE INSTALLED PRIOR TO SITE ACCEPTANCE. CITY APPROVAL OF
THE DUKE STREET LIGHTING PLAN IS REQUIRED PRIOR TO FINALIZATION. POLES AND
FIXTURES ARE REQUIRED TO BE DECORATIVE
10. ALL SIGNAGE AND STRIPING TO BE INSTALLED IN ACCORDANCE WITH
MUTCD (LATEST EDITION) STANDARDS AND SPECIFICATIONS. ALL SIGNAGE IS TO BE
DECORATIVE. ALL STRIPING TO BE THEREMOPLASTIC.
11. ALL CONSTRUCTION DUMPSTERS TO BE WASTE PRO, NO EXCEPTIONS. DUMPSTERS ARE TO
BE LOCATED A MIN. OF 100' FROM ANY SITE BOUNDARY.
12. NO ONSITE BURNING IS ALLOWED AT ANY TIME.
13. ALL ORGANIC OR OTHER UNSUITABLE MATERIALS MUST BE HAULED OFF
THE SITE AND PROPERLY DISPOSED.
14. PAYMENT OF THE 1% SITE INSPECTION FEE IS DUE PRIOR TO BREAKING
GROUND. FEE IS 1% OF THE TOTAL SITEWORK CONSTRUCTION COST, NOT
INCLUDING ITEMS COVERED BY A BUILDING PERMIT.
15. PROVIDE A VIDEO INSPECTION OF ALL SANITARY SEWER MAINS, SANITARY
SEWER LATERALS, AND ALL STORMWATER PIPES. PROVIDE THE CITY WITH
A DVD COPY OF ALL VIDEO INSPECTIONS.
16. ALL WORK PERFORMED WITHIN THE FDOT RIGHT-OF-WAY (S.R. 434) SHALL BE IN
ACCORDANCE WITH 2017 DESIGN STANDARDS, 2017 STANDARD
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, AND 2010 UTILITY
ACCOMODATION MANUAL.
17. A 6' CHAIN LINK FENCE WITH EITHER GREEN OR BLACK OPAQUE PRIVACY SCREEN IS
REQUIRED TO BE INSTALLED AROUND THE PROJECT PERIMETER PRIOR TO SITE WORK AND MAINTAINED
THROUGHOUT THE DURATION OF THE PROJECT.
18. A REFUNDABLE STORMWATER POLLUTION PREVENTION PLAN CASH DEPOSIT OR LETTER
OF CREDIT FOR THE LESSER OF 1% OF THE SITE CONSTRUCTION COST OR $5,000 IS
REQUIRED AT THE PRE-CONSTRUCTION MEETING
1. CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES SERVING THE STRUCTURE.
2. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING
UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND
WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS
BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST
72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE
PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
3. ALL CUT OR FILL SLOPES SHALL BE 4:1 OR FLATTER UNLESS OTHERWISE NOTED.
4. PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
5. EXISTING AND NEWLY INSTALLED PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
6. STORM PIPE SHALL BE PER MASTER SITE SPECIFICATIONS SECTION 02630 (ADS HP STORM OR EQUIVALENT)
7. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO
RETURN IT TO EXISTING CONDITIONS OR BETTER.
8. ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS
WATERTIGHT
9. ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE
TRAFFIC BEARING RING & COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISH GRADE. LIDS
SHALL BE LABELED "STORM SEWER".
10. THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE GENERAL N.P.D.E.S.
PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES.
11. CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT
AND CONTINUOUS GRADE.
12. CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED
13. ALL UNSURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL.
CONTRACTOR SHALL APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL
STABILIZE DISTURBED AREAS IN ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND
OF VEGETATION IS OBTAINED.
14. CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODES AND BE CONSTRUCTED TO SAME.
15. ALL STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT OUT.
16. TOPOGRAPHIC INFORMATION IS TAKEN FROM A TOPOGRAPHIC SURVEY BY LAND SURVEYOR CONSULTANT. IF THE CONTRACTOR
DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE CONTRACTOR
SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE OWNER
FOR REVIEW.
17. ALL EXISTING MANHOLE RIMS TO BE FLUSH WITH FINISHED GRADE. CONTRACTOR TO INSTALL MANHOLE RISERS OR
ADJUST EXISTING FRAMES AS NECESSARY.
18. EXISTING GRATE ELEVATIONS TO REMAIN. WHERE PAVEMENT OVERLAY IS TO BE PLACED, FEATHER OVERLAY TO
MATCH EXISTING GRATE ELEVATION TO FORM A SMOOTH TRANSITION.
19. SPOT ELEVATIONS ADJACENT TO CURBS REPRESENT EDGE OF PAVEMENT ELEVATIONS, TOP OF CURB SHOULD BE CONSIDERED 6" HIGHER.
20. CONTRACTOR TO MATCH EXISTING GRADE AT LIMITS OF DISTURBANCE, AS DEPICTED ON SWPPP SITE MAPS
21. STRIP THE SURFICIAL ORGANIC SANDS AND IMPORT A MINIMUM OF 2 FEET OF PRE-APPROVED ENGINEERED FILL
WITHIN THE LIMITS OF PROPOSED BUILDING FOUNDATIONS AND PAVEMENT.
22. AFTER STRIPPING IS COMPLETE, THE EXPOSED SUBGRADE SHALL BE OBSERVED, TESTED AND PROOF-ROLLED WITH
A MINIMUM OF 10 PASSES WITH A HEAVY VIBRATORY ROLLER IN PERPENDICULAR DIRECTIONS.
23. FILL SHALL BE COMPACTED IN LIFTS NO THICKER THAN 9 TO 12 INCHES IN LOOSE THICKNESS, WITH EACH LIFT COMPACTED
TO AT LEAST 95 PERCENT OF THE SOILS MODIFIED PROCTOR DRY DENSITY, (ASTM D-1557), AT A DEPTH OF 1 FOOT BELOW
THE COMPACTED SURFACE, AS DETERMINED BY IN-PLACE DENSITY TESTS.
24. FILL SHALL BE COMPACTED TO 95 PERCENT OF THE MATERIAL'S MAXIMUM MODIFIED PROCTOR DRY DENSITY
25. IMPORTED FILL OR BACKFILL SHOULD CONSIST OF FINE SAND WITH LESS THAN 15 PERCENT PASSING THE NO. 200 SIEVE, FREE
26. MOISTURE CONTENT OF THE FILL SHALL BE WITH IN +/-2 PERCENT OF OPTIMUM MOISTURE CONTENT AS
ESTABLISHED IN ASTM D-1557.
27. ONE FIELD DENSITY TEST SHALL BE CONDUCTED PER 2,500 SQUARE FEET (OR FRACTION THEREOF) PER LIFT, IN THE BUILDING AREA,
28. ALTHOUGH THE EXPOSED SUBGRADE IS ANTICIPATED TO BE RELATIVELY STABLE UPON INITIAL EXPOSURE,
UNSTABLE SUBGRADE CONDITIONS COULD DEVELOP DURING GENERAL CONSTRUCTION OPERATIONS IF THE SOILS ARE
WETTED AND/OR SUBJECTED TO REPETITIVE CONSTRUCTION TRAFFIC.
SITE GRADING NOTES:
SITE UTILITY NOTES:
1. ALL FILL MATERIAL IS TO BE IN PLACE, AND COMPACTED BEFORE INSTALLATION OF
PROPOSED UTILITIES.
2. CONTRACTOR SHALL NOTIFY THE PROPER UTILITIES AUTHORITIES 48 HOURS PRIOR TO ANY
UTILITIES CONSTRUCTION.
3. SANITARY SEWER GRAVITY PIPE SHALL BE AS FOLLOWS:
- 8" PVC SDR35 PER ASTM D 3034, FOR PIPES LESS THAN 10' DEEP
- 8" PVC SDR26 PER ASTM D 3034, FOR PIPES MORE THAN 10' DEEP
- 6" PVC SDR 35 PER ASTM D3034
4. WATER LINES SHALL BE AS FOLLOWS, UNLESS OTHERWISE DEPICTED ON PLANS:
- 3" AND SMALLER, PVC ASTM D 221, WITH SDR 21 RATING, CONTINUALLY MARKED WITH
MFR'S NAME PIPE SIZE, CELL CLASSIFICATION, SDR RATING, AND ASTM D1748 MAT. CLASS
- 4" TO 16", PVC, AWWA C900, RATED DR18 (CLASS 150), CONTINUALLY MARKED AS REQ'D
- 4" TO 16", DIP, AWWA C151, PRESSURE CLASS 350 (4-12"), PRESSURE CLASS 250 (14-16")
5. MINIMUM TRENCH WIDTH SHALL BE 2 FEET.
6. CONTRACTOR SHALL MAINTAIN A MINIMUM OF 3'-0" COVER ON ALL WATERLINES AND
SANITARY SEWER.
7. LINES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED BY CITY
OF WINTER SPRINGS PUBLIC WORKS/UTILITIES BEFORE BACKFILLING. CONTRACTOR TO PROVIDE
A MINIMUM 48 HOURS NOTICE.
8. TOPS OF EXISTING MANHOLES SHALL BE RAISED AS NECESSARY TO BE FLUSH WITH
PROPOSED PAVEMENT ELEVATIONS, AND TO BE SIX INCHES ABOVE UNPAVED GROUND
ELEVATIONS WITH WATER TIGHT LIDS.
9. EXISTING UTILITIES HAVE BEEN FIELD VERIFIED, HOWEVER, EXISTING UTILITIES SHALL BE
RE-VERIFIED IN FIELD PRIOR TO INSTALLATION OF ANY NEW LINES. THE EXISTING SANITARY
SEWER SIZE, LOCATION, AND ELEVATION SHALL BE VERIFIED PRIOR TO CONSTRUCTION
AND DEPICTED ON THESE PLANS.
10. REFER TO INTERIOR PLUMBING DRAWINGS FOR TIE-IN OF ALL UTILITIES.
11. ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS REQUIRED BY CODES AND/OR
UTILITY SERVICE COMPANIES SHALL BE PERFORMED PRIOR TO ANNOUNCED BUILDING
POSSESSION AND THE FINAL CONNECTION OF SERVICES.
12. CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION
REQUIREMENTS AND SPECIFICATIONS.
13. ALL WATER JOINTS ARE TO BE MECHANICAL RESTRAINED JOINTS.
14. IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATER LINES, SANITARY LINES, STORM
LINES AND GAS LINES (EXISTING AND PROPOSED), THE SANITARY LINE SHALL BE DUCTILE
IRON PIPE WITH MECHANICAL JOINTS AT LEAST 10 FEET ON BOTH SIDES OF CROSSING, THE
WATER LINE SHALL HAVE MECHANICAL RESTRAINED JOINTS AS REQUIRED TO PROVIDE A
MINIMUM OF 18" CLEARANCE. MEETING REQUIREMENTS OF ANSI A21.10 OR ANSI 21.11 (AWWA
C-151) (CLASS 50).
15. SANITARY LINES 6" AND GREATER ARE TO HAVE A MIN. SLOPE OF 0.40% AND MAINTAIN A MIN
SLOPE OF 2FPS.ALL SANITARY LATERALS (LESS THAN 6" DIAMETER) SHALL BE SLOPED AT A
MINIMUM OF 1.00%.
16. CONTRACTOR SHALL TURN OFF THE CORPORATION STOPS AT THE METERS FOR ALL WATER
SERVICES THAT ARE TO BE REMOVED.
17. WHEN ANY ROOTS OF EXISTING TREES ARE ENCOUNTERED DURING LAND CLEARING
AND/OR GRADING OF THE SITE THE ROOTS MUST BE CUT OFF EVENLY WITH CLEAN SHARP
PRUNING TOOLS. CONTRACTOR SHALL MINIMIZE DAMAGE TO TREE ROOT SYSTEM.
18. A MINIMUM OF 5 FT SEPARATION SHALL BE PROVIDED BETWEEN THE UNDERGROUND
UTILITIES AND ANY PROPOSED LARGE CANOPY TREES.
19. PRIVATE DEDICATED UNDERGROUND FIRE MAINS AND FIRE HYDRANTS MUST BE INSTALLED
BY A LICENSED FIRE CONTRACTOR CLASS I, II, III, IV. COMBINATION FIRE MAINS (SHARED
DOMESTIC AND FIRE PROTECTION SERVICE) AND FIRE HYDRANTS UP TO THE DEDICATED
FIRE PROTECTION SYSTEM "POINT OF SERVICE" CAN BE INSTALLED BY A LICENSED
UNDERGROUND UTILITY/EXCAVATION CONTRACTOR, GENERAL CONTRACTOR, OR PLUMBING
CONTRACTOR.
20. UNDERGROUND FIRE MAINS WILL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH
NFPA 24-2007 EDITION. STANDARDS FOR THE INSTALLATION OF PRIVATE FIRE SERVICE
MAINS AND THEIR APPURTENANCES.
21. IN PAVED AREAS, ALL CLEANOUT COVERS AND VALVE BOXES SHALL BE TRAFFIC RATED AND
FLUSH WOTH TOP OF PAVEMENT.
22. ALL SANITARY MANHOLES SHALL HAVE INCLUDE TROWEL-FINISHED CONCRETE BENCHING.
1 TEST PER 5,000 SQUARE FEET IN PAVEMENT AREAS.
OF RUBBLE, ORGANICS, CLAY, DEBRIS, AND OTHER UNSUITABLE MATERIAL.
29. LANDSCAPED AREAS BETWEEN RESIDENTIAL BUILDINGS AND SIDEWALKS ALONG PUBLIC ROADS SHALL BE SLOPED SUCH THAT THE
EXPOSED FOOTER OF THE BUILDING IS A MINIMUM OF 1 FOOT AND MAXIMUM OF 2.5 FEET.
30. PER TOWN CENTER CODE ALL RESIDENTIAL FINISHED FLOORS MUST BE 2 FEET ABOVE THE ADJACENT SIDEWALK GRADE.
SITEWORK SPECIFICATIONS:
CIVIL ENGINEERING SITEWORK SPECIFICATIONS ARE INTEGRAL TO THIS PLAN SET AND INCLUDED IN THE FINAL PERMIT SET OF
DOCUMENTATION FROM THE CITY OF WINTER SPRINGS. THE CONTRACTOR SHALL OBTAIN A COPY BY CONTACTING NV5.
VERTICAL DATUM:
ALL ELEVATIONS ARE BASED ON NGVD 1929 VERTICAL DATUM
GROUND SURFACES.
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTONLYONLYONLYLOT 3
0.67 AC
STARBUCKS
2,500 SF RTONLYONLYONLY41.39 X
X41.20
X39.33
IP1
IP1
IP1
DISCHARGE POINT
LIMITS OF DISTURBANCE
SILT FENCE
IP1
CE 20'50'
SFSFSFSFSFSFSFSF SF SF SF SF SF SF SF SF SFSF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFIP2
IP2 NORTH40200
SCALE: 1" = 20'
3. MAINTENANCE:
1.SILT FENCE SHALL BE INSPECTED AT LEAST WEEKLY. ANY REQUIRED REPAIRS SHALL
BE MADE IMMEDIATELY. SEDIMENT DEPOSITS SHALL BE REMOVED WHEN THEY
REACH APPROXIMATELY ONE-HALF THE HEIGHT OF THE BARRIER.
2.INLETS SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAIN EVENT AND ANY
REPAIRS SHALL BE PERFORMED IMMEDIATELY.
3.BARE AREAS OF THE SITE THAT WERE PREVIOUSLY SEEDED SHALL BE RE-SEEDED
PER MANUFACTURES' INSTRUCTIONS.
4.MULCH AND SOD THAT HAS BEEN WASHED OUT SHALL BE REPLACED IMMEDIATELY.
ALL MEASURES ON THIS SITE MAP, AND IN THE STORM WATER POLLUTION PREVENTION
PLAN, SHALL BE MAINTAINED IN FULLY FUNCTIONAL CONDITION UNTIL NO LONGER
REQUIRED FOR A COMPLETED PHASE OF WORK OR FINAL STABILIZATION OF THE SITE.
CONTROLS ARE TO BE REPLACED OR REPAIRED IF IN A SUBSTANDARD CONDITION. ALL
MAINTENANCE MODIFICATIONS ARE TO BE NOTED, ON PLANS, AS THEY OCCUR.
4. INSPECTIONS:
A QUALIFIED INSPECTOR SHALL INSPECT ALL POINTS OF DISCHARGE INTO SURFACE
WATERS OF THE STATE AND MS4 (CITY OF WINTER SPRINGS & FDOT); DISTURBED AREAS
OF THE CONSTRUCTION SITE THAT HAVE NOT BEEN FINALLY STABILIZED; AREAS USED
FOR STORAGE OF MATERIALS THAT ARE EXPOSED TO PRECIPITATION; STRUCTURAL
CONTROLS; AND, LOCATIONS WHERE VEHICLES ENTER OR EXIT THE SITE, AT LEAST ONCE
EVERY SEVEN CALENDAR DAYS AND WITHIN 24 HOURS OF THE END OF A STORM THAT IS
0.50 INCHES OR GREATER. A REPORT SUMMARIZING THE SCOPE OF THE INSPECTION
SHALL BE MADE AND RETAINED IN THE CONSTRUCTION TRAILER AS PART OF THE
STORMWATER POLLUTION PREVENTION
5. NON-STORMWATER DISCHARGES:
IT IS ANTICIPATED THAT THE FOLLOWING NON-STORMWATER DISCHARGES MAY OCCUR
FROM THE SITE DURING THE CONSTRUCTION PERIOD:
1.WATER FROM LINE FLUSHINGS
2.PAVEMENT WASH WATER (WHERE NO SPILLS OR LEAKS OF TOXIC OR HAZARDOUS
MATERIALS HAVE OCCURRED)
3.SITE WATERING, TO ALLEVIATE FUGATIVE DUST
4.ROUTINE EXTERNAL BUILDING WASHDOWN WHICH DOES NOT USE DETERGENTS
5.IRRIGATION DRAINAGE
IF SAID DISCHARGES DO OCCUR, THEY WILL BE DIRECTED TO THE TEMPORARY EROSION
CONTROL MEASURES PRIOR TO DISCHARGE
6. CONTRACTOR/SUBCONTRACTOR CERTIFICATION:
ALL CONTRACTOR(S) AND SUBCONTRACTOR(S) IDENTIFIED ABOVE MUST SIGN THE
FOLLOWING CERTIFICATION: "I CERTIFY UNDER PENALTY OF LAW THAT I UNDERSTAND,
AND SHALL COMPLY WITH, THE TERMS AND CONDITIONS OF THE STATE OF FLORIDA
GENERIC PERMIT FOR STORMWATER DISCHARGE FROM LARGE AND SMALL
CONSTRUCTION ACTIVITIES AND THIS STORMWATER POLLUTION PREVENTION PLAN
PREPARED THEREUNDER."
B. PERMANENT STORMWATER MANAGEMENT CONTROLS:
1.CATCH BASINS AND STORM SEWER SYSTEM ON-SITE TO PROVIDE POSITIVE DRAINAGE OF THE
ENTIRE SITE TO THE DISCHARGE POINT.
C. CONTROLS FOR OTHER POLLUTANTS:
1.WASTE DISPOSAL: ALL WASTE WILL BE DISPOSED OF IN AN APPROPRIATE LEGAL MANOR, AND
COMPLY WITH CITY OF WINTER SPRINGS ORDINANCES FOR WASTE DISPOSAL AND
COMMERCIAL SITE DEVELOPMENT.
2.VEHICLE TRACKING: OFF SITE VEHICLE TRACKING OF SEDIMENTS AND DUST GENERATION WILL
BE MINIMIZED VIA BEST POSSIBLE PRACTICES, DAILY SWEEPING AND THE USE OF WATER TO
KEEP DUST DOWN.
3.FERTILIZERS, HERBICIDES, AND PESTICIDES: FERTILIZERS AND PESTICIDES WILL BE USED AT A
MINIMUM AND IN ACCORDANCE WITH THE MANUFACTURERS' SUGGESTED APPLICATION
APPLICATION RATES. THE FERTILIZERS AND PESTICIDES SHALL BE STORED IN A COVERED
SHED.
4.TOXIC SUBSTANCES: ALL PAINTS AND OTHER CHEMICALS WILL BE STORED IN A LOCKED
COVERED SHED.
5.OTHER: PORT-O-LETS WILL BE PLACED AWAY FROM THE STORM SEWER SYSTEMS AND STORM
INLETS. NO VEHICLE MAINTENANCE SHALL BE CONDUCTED ON-SITE. A WASHDOWN AREA
SHALL BE DESIGNATED AT ALL TIMES AND WILL NOT BE LOCATED IN ANY AREA THAT WILL
ALLOW FOR THE DISCHARGE OF POLLUTED RUNOFF. A SMALL VEGETATED BERM SHALL BE
PLACED AROUND THE WASHDOWN AREA.
BEST MANAGEMENT PRACTICES SEQUENCE
1. SITE DESCRIPTION
A. CONSTRUCTION OF COMMERCIAL RETAIL BUILDINGS, PUBLIC ROADS, AND SURFACE PARKING
AREAS.
B. SEQUENCE OF SOIL DISTURBANCE:
(1) INSTALL PERIMETER SEDIMENT AND EROSION CONTROLS.
(2) PREPARE SITE.
(3) CLEAR AND GRUB PROPOSED AREA.
(4) INSTALL PROPOSED UNDERGROUND STORMWATER AND UTILITIES.
(5) INSTALL CONCRETE CURB, CONCRETE SIDEWALK. AND PAVEMENT
(6) STABILIZE SITE.
C.TOTAL SITE AREA:0.83± ACRES
DISTURBED SITE AREA:0.83± ACRES
D. SOILS: THE SOILS (PER NRCS) POMELLO, ST JOHNS/EAUGALLIE
E. DRAINAGE AREA FOR EXISTING DISCHARGE POINT:0.83± ACRES
DRAINAGE AREA FOR PROPOSED DISCHARGE POINT:0.83± ACRES
F.LATITUDE AND LONGITUDE OF EXISTING DISCHARGE POINT:
DISCHARGE POINT LAT:28° 41' 46.75" N
DISCHARGE POINT LONG:81°15' 38.85" W
DISCHARGES TO EXISTING STORM WATER SYSTEM
LATITUDE AND LONGITUDE OF PROPOSED DISCHARGE POINT:
DISCHARGE POINT LAT:28° 41' 46.75" N
DISCHARGE POINT LONG:81°15' 38.85" W
DISCHARGES TO EXISTING STORM WATER SYSTEM
2. CONTROLS
A. EROSION AND SEDIMENT CONTROLS:
(1) STABILIZATION PRACTICES:
1.TEMPORARY SEEDING SHALL BE RYE GRASS APPLIED AT MANUFACTURER'S
RECOMMENDATIONS TO ANY DISTURBED AREAS THAT ARE INACTIVE FOR SEVEN DAYS.
2.MULCHING PRACTICES AND SOD SHALL BE APPLIED TO PARKING LOT ISLANDS.
(2) STRUCTURAL PRACTICES:
1.PRIOR TO CLEARING, A SILT FENCE SHALL BE INSTALLED AROUND THE PERIMETER OF THE
SITE, AS SHOWN HEREIN.
2.DURING THE CLEARING, GRUBBING, AND SITE GRADING STAGES, AREAS TO BE LEFT
DISTURBED MORE THAN 7 DAYS SHALL BE STABILIZED WITH RYE GRASS APPLIED PER THE
MANUFACTURER'S SPECIFICATIONS. AFTER SEEDING, EACH AREA SHALL BE MULCHED WITH
4,000 POUNDS OF STRAW PER ACRE.
3.AFTER ALL INITIAL SITE GRADING WORK, ALL PROPOSED INLETS/OUTFALLS, ONCE INSTALLED,
SHALL BE PROTECTED FROM EROSION AND SEDIMENT RUNOFF BY THE USE OF THE INLET
PROTECTION DESIGNATED ON THE SITE MAP. DISTURBED PORTIONS OF THE SITE WHERE
CONSTRUCTION ACTIVITIES HAVE PERMANENTLY CEASED SHALL BE STABILIZED WITH SEED OR
SOD AS INDICATED ON THE SITE MAP NO LATER THAN 14 DAYS AFTER THE LAST
CONSTRUCTION ACTIVITY. SEEDING SHALL BE THE SAME AS IN TEMPORARY SEEDING.
4.ALL INSTALLATION SHALL BE COMMENCED AS DEPICTED ON THE SITE MAPS AND EROSION
CONTROL DETAIL SHEET.
5.IF SEDIMENT AND EROSION CONTROL MEASURES DEVIATE FROM THE PLANS THE CITY OF
WINTER SPRINGS SHALL BE NOTIFIED.
EROSION DETAILS
LEGEND
TEMPORARY SILT FENCE WITH WIRE
SUPPORT (SEE DETAIL 7, SHEET C8.0)
CURB INLET PROTECTION
(SEE DETAIL 7, SHEET C8.0)
PROPERTY LINE
PROPOSED LIMITS
OF DISTURBANCE
IP1
SF
CE
SF
INLET PROTECTION
(SEE DETAIL 7, SHEET C8.0)IP2
(SEE DETAIL 7, SHEET C8.0)FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Feb. 15, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065SWPPP PHASE 1 PLANC2.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUPNOTE: THE LIMITS OF DISTURBANCE SHALL BE
STRICKLY ADHERED TO
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTLOT 4
0.83 AC
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTS.R. 434 MICHAEL BLAKE BLVD.X
X
X39.33
IP1
IP1
IP1
DISCHARGE POINT
LIMITS OF DISTURBANCE
SILT FENCE
IP1
CE
20'50'SFSFSFSFSFSFSF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFIP2
IP2 SFSFSFSFSFSFIP2 IP2 IP2
IP2 IP2 IP2 NORTH40200
SCALE: 1" = 20'
EROSION DETAILS
LEGEND
TEMPORARY SILT FENCE WITH WIRE
SUPPORT (SEE DETAIL 7, SHEET C8.0)
CURB INLET PROTECTION
(SEE DETAIL 7, SHEET C8.0)
PROPERTY LINE
PROPOSED LIMITS
OF DISTURBANCE
IP1
SF
CE
SF
3. MAINTENANCE:
1.SILT FENCE SHALL BE INSPECTED AT LEAST WEEKLY. ANY REQUIRED REPAIRS SHALL
BE MADE IMMEDIATELY. SEDIMENT DEPOSITS SHALL BE REMOVED WHEN THEY
REACH APPROXIMATELY ONE-HALF THE HEIGHT OF THE BARRIER.
2.INLETS SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAIN EVENT AND ANY
REPAIRS SHALL BE PERFORMED IMMEDIATELY.
3.BARE AREAS OF THE SITE THAT WERE PREVIOUSLY SEEDED SHALL BE RE-SEEDED
PER MANUFACTURES' INSTRUCTIONS.
4.MULCH AND SOD THAT HAS BEEN WASHED OUT SHALL BE REPLACED IMMEDIATELY.
ALL MEASURES ON THIS SITE MAP, AND IN THE STORM WATER POLLUTION PREVENTION
PLAN, SHALL BE MAINTAINED IN FULLY FUNCTIONAL CONDITION UNTIL NO LONGER
REQUIRED FOR A COMPLETED PHASE OF WORK OR FINAL STABILIZATION OF THE SITE.
CONTROLS ARE TO BE REPLACED OR REPAIRED IF IN A SUBSTANDARD CONDITION. ALL
MAINTENANCE MODIFICATIONS ARE TO BE NOTED, ON PLANS, AS THEY OCCUR.
4. INSPECTIONS:
A QUALIFIED INSPECTOR SHALL INSPECT ALL POINTS OF DISCHARGE INTO SURFACE
WATERS OF THE STATE AND MS4 (CITY OF WINTER SPRINGS & FDOT); DISTURBED AREAS
OF THE CONSTRUCTION SITE THAT HAVE NOT BEEN FINALLY STABILIZED; AREAS USED
FOR STORAGE OF MATERIALS THAT ARE EXPOSED TO PRECIPITATION; STRUCTURAL
CONTROLS; AND, LOCATIONS WHERE VEHICLES ENTER OR EXIT THE SITE, AT LEAST ONCE
EVERY SEVEN CALENDAR DAYS AND WITHIN 24 HOURS OF THE END OF A STORM THAT IS
0.50 INCHES OR GREATER. A REPORT SUMMARIZING THE SCOPE OF THE INSPECTION
SHALL BE MADE AND RETAINED IN THE CONSTRUCTION TRAILER AS PART OF THE
STORMWATER POLLUTION PREVENTION
5. NON-STORMWATER DISCHARGES:
IT IS ANTICIPATED THAT THE FOLLOWING NON-STORMWATER DISCHARGES MAY OCCUR
FROM THE SITE DURING THE CONSTRUCTION PERIOD:
1.WATER FROM LINE FLUSHINGS
2.PAVEMENT WASH WATER (WHERE NO SPILLS OR LEAKS OF TOXIC OR HAZARDOUS
MATERIALS HAVE OCCURRED)
3.SITE WATERING, TO ALLEVIATE FUGATIVE DUST
4.ROUTINE EXTERNAL BUILDING WASHDOWN WHICH DOES NOT USE DETERGENTS
5.IRRIGATION DRAINAGE
IF SAID DISCHARGES DO OCCUR, THEY WILL BE DIRECTED TO THE TEMPORARY EROSION
CONTROL MEASURES PRIOR TO DISCHARGE
6. CONTRACTOR/SUBCONTRACTOR CERTIFICATION:
ALL CONTRACTOR(S) AND SUBCONTRACTOR(S) IDENTIFIED ABOVE MUST SIGN THE
FOLLOWING CERTIFICATION: "I CERTIFY UNDER PENALTY OF LAW THAT I UNDERSTAND,
AND SHALL COMPLY WITH, THE TERMS AND CONDITIONS OF THE STATE OF FLORIDA
GENERIC PERMIT FOR STORMWATER DISCHARGE FROM LARGE AND SMALL
CONSTRUCTION ACTIVITIES AND THIS STORMWATER POLLUTION PREVENTION PLAN
PREPARED THEREUNDER."
INLET PROTECTION
(SEE DETAIL 7, SHEET C8.0)IP2
(SEE DETAIL 7, SHEET C8.0)
B. PERMANENT STORMWATER MANAGEMENT CONTROLS:
1.CATCH BASINS AND STORM SEWER SYSTEM ON-SITE TO PROVIDE POSITIVE DRAINAGE OF THE
ENTIRE SITE TO THE DISCHARGE POINT.
C. CONTROLS FOR OTHER POLLUTANTS:
1.WASTE DISPOSAL: ALL WASTE WILL BE DISPOSED OF IN AN APPROPRIATE LEGAL MANOR, AND
COMPLY WITH CITY OF WINTER SPRINGS ORDINANCES FOR WASTE DISPOSAL AND
COMMERCIAL SITE DEVELOPMENT.
2.VEHICLE TRACKING: OFF SITE VEHICLE TRACKING OF SEDIMENTS AND DUST GENERATION WILL
BE MINIMIZED VIA BEST POSSIBLE PRACTICES, DAILY SWEEPING AND THE USE OF WATER TO
KEEP DUST DOWN.
3.FERTILIZERS, HERBICIDES, AND PESTICIDES: FERTILIZERS AND PESTICIDES WILL BE USED AT A
MINIMUM AND IN ACCORDANCE WITH THE MANUFACTURERS' SUGGESTED APPLICATION
APPLICATION RATES. THE FERTILIZERS AND PESTICIDES SHALL BE STORED IN A COVERED
SHED.
4.TOXIC SUBSTANCES: ALL PAINTS AND OTHER CHEMICALS WILL BE STORED IN A LOCKED
COVERED SHED.
5.OTHER: PORT-O-LETS WILL BE PLACED AWAY FROM THE STORM SEWER SYSTEMS AND STORM
INLETS. NO VEHICLE MAINTENANCE SHALL BE CONDUCTED ON-SITE. A WASHDOWN AREA
SHALL BE DESIGNATED AT ALL TIMES AND WILL NOT BE LOCATED IN ANY AREA THAT WILL
ALLOW FOR THE DISCHARGE OF POLLUTED RUNOFF. A SMALL VEGETATED BERM SHALL BE
PLACED AROUND THE WASHDOWN AREA.
BEST MANAGEMENT PRACTICES SEQUENCE
1. SITE DESCRIPTION
A. CONSTRUCTION OF COMMERCIAL RETAIL BUILDINGS, PUBLIC ROADS, AND SURFACE PARKING
AREAS.
B. SEQUENCE OF SOIL DISTURBANCE:
(1) INSTALL PERIMETER SEDIMENT AND EROSION CONTROLS.
(2) PREPARE SITE.
(3) CLEAR AND GRUB PROPOSED AREA.
(4) INSTALL PROPOSED UNDERGROUND STORMWATER AND UTILITIES.
(5) INSTALL CONCRETE CURB, CONCRETE SIDEWALK. AND PAVEMENT
(6) STABILIZE SITE.
C.TOTAL SITE AREA:0.83± ACRES
DISTURBED SITE AREA:0.83± ACRES
D. SOILS: THE SOILS (PER NRCS) POMELLO, ST JOHNS/EAUGALLIE
E. DRAINAGE AREA FOR EXISTING DISCHARGE POINT:0.83± ACRES
DRAINAGE AREA FOR PROPOSED DISCHARGE POINT:0.83± ACRES
F.LATITUDE AND LONGITUDE OF EXISTING DISCHARGE POINT:
DISCHARGE POINT LAT:28° 41' 46.75" N
DISCHARGE POINT LONG:81°15' 38.85" W
DISCHARGES TO EXISTING STORM WATER SYSTEM
LATITUDE AND LONGITUDE OF PROPOSED DISCHARGE POINT:
DISCHARGE POINT LAT:28° 41' 46.75" N
DISCHARGE POINT LONG:81°15' 38.85" W
DISCHARGES TO EXISTING STORM WATER SYSTEM
2. CONTROLS
A. EROSION AND SEDIMENT CONTROLS:
(1) STABILIZATION PRACTICES:
1.TEMPORARY SEEDING SHALL BE RYE GRASS APPLIED AT MANUFACTURER'S
RECOMMENDATIONS TO ANY DISTURBED AREAS THAT ARE INACTIVE FOR SEVEN DAYS.
2.MULCHING PRACTICES AND SOD SHALL BE APPLIED TO PARKING LOT ISLANDS.
(2) STRUCTURAL PRACTICES:
1.PRIOR TO CLEARING, A SILT FENCE SHALL BE INSTALLED AROUND THE PERIMETER OF THE
SITE, AS SHOWN HEREIN.
2.DURING THE CLEARING, GRUBBING, AND SITE GRADING STAGES, AREAS TO BE LEFT
DISTURBED MORE THAN 7 DAYS SHALL BE STABILIZED WITH RYE GRASS APPLIED PER THE
MANUFACTURER'S SPECIFICATIONS. AFTER SEEDING, EACH AREA SHALL BE MULCHED WITH
4,000 POUNDS OF STRAW PER ACRE.
3.AFTER ALL INITIAL SITE GRADING WORK, ALL PROPOSED INLETS/OUTFALLS, ONCE INSTALLED,
SHALL BE PROTECTED FROM EROSION AND SEDIMENT RUNOFF BY THE USE OF THE INLET
PROTECTION DESIGNATED ON THE SITE MAP. DISTURBED PORTIONS OF THE SITE WHERE
CONSTRUCTION ACTIVITIES HAVE PERMANENTLY CEASED SHALL BE STABILIZED WITH SEED OR
SOD AS INDICATED ON THE SITE MAP NO LATER THAN 14 DAYS AFTER THE LAST
CONSTRUCTION ACTIVITY. SEEDING SHALL BE THE SAME AS IN TEMPORARY SEEDING.
4.ALL INSTALLATION SHALL BE COMMENCED AS DEPICTED ON THE SITE MAPS AND EROSION
CONTROL DETAIL SHEET.
5.IF SEDIMENT AND EROSION CONTROL MEASURES DEVIATE FROM THE PLANS THE CITY OF
WINTER SPRINGS SHALL BE NOTIFIED.FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Feb. 15, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065SWPPP PHASE 2 PLANC3.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUP
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTONLYONLYONLYLOT 4
0.83 AC
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTONLYONLYONLYS.R. 434 MICHAEL BLAKE BLVD.7,200 SF
60'18'3.32'18 9
120'
18'18'22'18'6'9'12'12.55'
15.39'
9 9'
1118'22'4
18'
3'R.
A
24'10'R.5'10'7'11'
9'22'
5'
3'R.3'R.
3'
R
.10'R.1
0
'
R
.
1
0
'
R
.
3'3'6'5'20'9'3'R.12'12.10'B C
C
B
B
B
D
D
D
D
D
L
E
F
G
HREMOVE 107LF OF EXISTING CURB AND GUTTERI
I
I
J
J
K
M
12'
SWSL/24"
SWSL/12"
SWSL/4"
SWSL/4"
SWSL/12"
N
EDGE OF PAVEMENT
TO BE FLUSH WITH
SIDEWALK
CURBED
SIDEWALK
O
O
P 10'R.9'
15.31'17.42'13.56'M
6'12'L
Q
REMOVE EXISTING SIDEWALK
3.5'C
R
SS
T
T
T
11.5'
4'
A
P
5'P
V
FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Mar. 14, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065SITE PLANC4.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUPNORTH40200
SCALE: 1" = 20'
B
D
G
H
J
SITE LEGEND
ACCESSIBLE PARKING SPACE (TYP). SEE DETAIL FOR ACCESSIBLE PARKING SPACE, SIGN AND SYMBOL. (SEE DETAIL
1, SHEET C8.0).
PAVEMENT MARKINGS (TYP). PER FDOT INDEX 17346
FDOT INDEX 304 HANDICAP RAMP WITH DETECTABLE WARNING SURFACE (TYP). (SEE DETAIL 2, SHEET C8.0).
18" CURB AND GUTTER (SEE DETAIL 3, SHEET C7.0).
CONCRETE SIDEWALK. (SEE DETAIL 1, SHEET C7.0).
(2) DUMPSTER ENCLOSURES ( (1)-RECYCLING & (1) TRASH ) PER ARCH. PLANS
BIKE RACKS. (SEE DETAIL 4, SHEET C8.0).
PROPOSED MONUMENT SIGN (SEE ARCH. PLANS). REQUIRES SEPARATE BUILDING PERMIT.
DECORATIVE 30" STOP SIGN (R1-1) - HIGH REFLECTIVE INTENSITY
PRIVATE PEDESTRIAN CROSSWALK WITH (1)-12" WHITE STRIPE PERPENDICULAR ON BOTH SIDES
(SEE DETAIL 7, SHEET C7.0). 6' WIDE UNLESS OTHER WISE NOTED ON PLANS.
TIE INTO EXISTING DECORATIVE KNEE WALL WITH 18LF OF DECORATIVE KNEEWALL TO MATCH EXISTING.
DECORATIVE END CAP TO BE PROVIDED. KNEE WALL AND END CAP TO BE PERMITTED SEPARATELY.
PROPOSED 12' WIDE CONCRETE SIDEWALK
DECORATIVE RAILING TO MATCH STARBUCKS TYPE AND COLOR. (PER ARCH. PLANS)
POTENTIAL TRANSFORMER LOCATION, FINAL LOCATION TO BE DETERMINED BY DUKE ENERGY.
6' CURB TRANSITION
CONCRETE WHEEL STOP
3.6' WIDE GREEN SPACE
6'X3' CONCRETE PAD FOR BFP (SEE UTILITY SHEET C6.0)
GATE, TO BE COMPLIANT WITH ADA REQUIRMENTS
LANDSCAPE PLANTERS. SEE LANDSCAPE PLANS
E
F
I
K
C
A
L
SITE INFORMATION:
SITE DATA:
LOT 4 0.83 AC 100.00%
OPEN SPACE PROVIDED: 0.104 AC (12.56%)
PARKING REQUIRED:
BASED ON GENERAL TENANT CRITERIA
PARKING PROVIDED:
STANDARD PARKING: (9' x 18') 47 SPACES
HC VAN ACCESSIBLE:(12' x 18') 3 SPACES
TOTAL: 50 SPACES
ON-STREET (OFFSITE):(9' x 20')6 SPACES
RECOMMENDED PARKING RATIO: 1 SPC / 300 SF = 7200 / 300 = 24 SPACES REQ.
EXISTING USE: VACANT LAND
PROPOSED USE: COMMERCIAL
BUILDING MIN HEIGHT: 2 STORIES
BUILDING MAX HEIGHT: 5 STORIES
FAR: SF = 0.19
T-5 BUILDING SETBACKS
REQUIRED:
FRONT MIN. 0 FT
FRONT MAX. 8 FT
REAR 3 FT
SIDE MIN. 0 FT
SIDE MAX. 24 FT
FRONTAGE BUILD OUT: 80% MIN.
LANDSCAPE BUFFER
ADJACENT TO R-O-W:0'
ADJACENT PROPERTY:0'
EXISTING ZONING/FUTURE LAND USE: TC
PROPOSED ZONING/FUTURE LAND USE: TC
NOTE: ALL SIGNS SHALL USE DECORATIVE BASE PER DETAIL 3, SHEET C8.0.
M
SINGLE WHITE SOLID LINE / 4" WIDE
SITE LEGEND
SWSL/4"
N
O
PAVEMENT LEGEND
4" REGULAR DUTY CONCRETE
PATIO AREA: U.S. PAVERSCAPE, MOCHA BLEND
SINGLE WHITE SOLID LINE / 12" WIDESWSL/12"
SINGLE WHITE SOLID LINE / 24" WIDESWSL/24"
P
Q
R
S
T
PROVIDED:
FRONT MAX: 21'
SIDE MAX: 90 FT (WEST)
FRONTAGE BUILD OUT: 53.3%
SEE DETAIL 10, SHEET C08.0
ASPHALT PAVING FOR ALLEYS, PARKING LOTS,
AND PRIVATE ROADS. SEE DETAIL 5, SHEET C07.0
ASPHALT PAVING FOR PUBLIC ROWS
SEE DETAIL 5, SHEET C07.0
RUNNING BOND PATTERN W/ LITHOCHROME
CLEAR SEALER, SEE DETAIL THIS SHEET
U.S. PAVERSCAPE, RUNNING BOND PATTERN
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTONLYONLYONLYLOT 4
0.83 AC
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTONLYONLYONLYS.R. 434 MICHAEL BLAKE BLVD.7,200 SF
60'18'3.32'18 9
120'
18'18'22'18'6'9'12'12.55'
15.39'
9 9'
1118'22'4
18'
3'R.
A
24'10'R.5'10'7'11'
9'22'
5'
3'R.3'R.
3'
R
.10'R.1
0
'
R
.
1
0
'
R
.
3'3'6'5'20'9'3'R.12'12.10'B C
C
B
B
B
D
D
D
D
D
L
E
F
G
HREMOVE 107LF OF EXISTING CURB AND GUTTERI
I
I
J
J
K
M
12'
SWSL/24"
SWSL/12"
SWSL/4"
SWSL/4"
SWSL/12"
N
EDGE OF PAVEMENT
TO BE FLUSH WITH
SIDEWALK
CURBED
SIDEWALK
O
O
P 10'R.9'
15.31'17.42'13.56'M
6'12'L
Q
REMOVE EXISTING SIDEWALK
3.5'C
R
SS
T
T
T
11.5'
4'
A
P
5'P
V
FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Mar. 14, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065SITE PLANC4.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUPNORTH40200
SCALE: 1" = 20'
B
D
G
H
J
SITE LEGEND
ACCESSIBLE PARKING SPACE (TYP). SEE DETAIL FOR ACCESSIBLE PARKING SPACE, SIGN AND SYMBOL. (SEE DETAIL
1, SHEET C8.0).
PAVEMENT MARKINGS (TYP). PER FDOT INDEX 17346
FDOT INDEX 304 HANDICAP RAMP WITH DETECTABLE WARNING SURFACE (TYP). (SEE DETAIL 2, SHEET C8.0).
18" CURB AND GUTTER (SEE DETAIL 3, SHEET C7.0).
CONCRETE SIDEWALK. (SEE DETAIL 1, SHEET C7.0).
(2) DUMPSTER ENCLOSURES ( (1)-RECYCLING & (1) TRASH ) PER ARCH. PLANS
BIKE RACKS. (SEE DETAIL 4, SHEET C8.0).
PROPOSED MONUMENT SIGN (SEE ARCH. PLANS). REQUIRES SEPARATE BUILDING PERMIT.
DECORATIVE 30" STOP SIGN (R1-1) - HIGH REFLECTIVE INTENSITY
PRIVATE PEDESTRIAN CROSSWALK WITH (1)-12" WHITE STRIPE PERPENDICULAR ON BOTH SIDES
(SEE DETAIL 7, SHEET C7.0). 6' WIDE UNLESS OTHER WISE NOTED ON PLANS.
TIE INTO EXISTING DECORATIVE KNEE WALL WITH 18LF OF DECORATIVE KNEEWALL TO MATCH EXISTING.
DECORATIVE END CAP TO BE PROVIDED. KNEE WALL AND END CAP TO BE PERMITTED SEPARATELY.
PROPOSED 12' WIDE CONCRETE SIDEWALK
DECORATIVE RAILING TO MATCH STARBUCKS TYPE AND COLOR. (PER ARCH. PLANS)
POTENTIAL TRANSFORMER LOCATION, FINAL LOCATION TO BE DETERMINED BY DUKE ENERGY.
6' CURB TRANSITION
CONCRETE WHEEL STOP
3.6' WIDE GREEN SPACE
6'X3' CONCRETE PAD FOR BFP (SEE UTILITY SHEET C6.0)
GATE, TO BE COMPLIANT WITH ADA REQUIRMENTS
LANDSCAPE PLANTERS. SEE LANDSCAPE PLANS
E
F
I
K
C
A
L
SITE INFORMATION:
SITE DATA:
LOT 4 0.83 AC 100.00%
OPEN SPACE PROVIDED: 0.104 AC (12.56%)
PARKING REQUIRED:
BASED ON GENERAL TENANT CRITERIA
PARKING PROVIDED:
STANDARD PARKING: (9' x 18') 47 SPACES
HC VAN ACCESSIBLE:(12' x 18') 3 SPACES
TOTAL: 50 SPACES
ON-STREET (OFFSITE):(9' x 20')6 SPACES
RECOMMENDED PARKING RATIO: 1 SPC / 300 SF = 7200 / 300 = 24 SPACES REQ.
EXISTING USE: VACANT LAND
PROPOSED USE: COMMERCIAL
BUILDING MIN HEIGHT: 2 STORIES
BUILDING MAX HEIGHT: 5 STORIES
FAR: SF = 0.19
T-5 BUILDING SETBACKS
REQUIRED:
FRONT MIN. 0 FT
FRONT MAX. 8 FT
REAR 3 FT
SIDE MIN. 0 FT
SIDE MAX. 24 FT
FRONTAGE BUILD OUT: 80% MIN.
LANDSCAPE BUFFER
ADJACENT TO R-O-W:0'
ADJACENT PROPERTY:0'
EXISTING ZONING/FUTURE LAND USE: TC
PROPOSED ZONING/FUTURE LAND USE: TC
NOTE: ALL SIGNS SHALL USE DECORATIVE BASE PER DETAIL 3, SHEET C8.0.
M
SINGLE WHITE SOLID LINE / 4" WIDE
SITE LEGEND
SWSL/4"
N
O
PAVEMENT LEGEND
4" REGULAR DUTY CONCRETE
PATIO AREA: U.S. PAVERSCAPE, MOCHA BLEND
SINGLE WHITE SOLID LINE / 12" WIDESWSL/12"
SINGLE WHITE SOLID LINE / 24" WIDESWSL/24"
P
Q
R
S
T
PROVIDED:
FRONT MAX: 21'
SIDE MAX: 90 FT (WEST)
FRONTAGE BUILD OUT: 53.3%
SEE DETAIL 10, SHEET C08.0
ASPHALT PAVING FOR ALLEYS, PARKING LOTS,
AND PRIVATE ROADS. SEE DETAIL 5, SHEET C07.0
ASPHALT PAVING FOR PUBLIC ROWS
SEE DETAIL 5, SHEET C07.0
RUNNING BOND PATTERN W/ LITHOCHROME
CLEAR SEALER, SEE DETAIL THIS SHEET
U.S. PAVERSCAPE, RUNNING BOND PATTERN
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTLOT 4
0.83 AC
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTS.R. 434 MICHAEL BLAKE BLVD.40.60
39.66
38.39
38.6238.50
40.47
38.12
38.00
41.10
40.75
39.00
39.50
39.40
38.80
39.54
40.35
37.60 38.87 38.25
39.11
38.61
EX 40.65
39.27
41.15
41.26
41.39
39.52
40.02
40.13
40.25
41.79
40.52
39.95
39.55 39.90
39.82
39.82
40.80 40.65
40.65
40.7540.85
41.20 41.10
40.7440.67
40.69
GRT.
40.44
40.74
GRT.
39.70
40.74
40.6040.15
40.05
40.15
40.27
40.22 40.32
40.36
2
1
3
GRT.
38.254
MEG
MEG
SC
SC
EDGE OF PAVEMENT
TO BE FLUSH WITH
SIDEWALK
F.F. 41.00
40.9840.9840.9840.9840.9840.98
40.52
40.5240.52
39.90 39.86
39.9639.96
40.54
GRT.
40.705GRT.40.706GRT.
40.70 7
41.50
40.68
40.24
40.14 40.20
40.48
39.22
39.42
39.66
39.46 39.53
39.7739.63
39.87
39.90
40.01
40.50
40.27
40.22
40.15
40.44
40.14
40.02
38.63
39.30
39.10
39.05
39.20
38.90
38.86
38.72
38.6038.60
38.72
39.2239.10
REMOVE EXISTING
STRUCTURE AND PIPE
REMOVE EXISTING TYPE P6 INL.
& REPLACE WITH TYPE VG INL.
39.22
39.10
38.75
39.30
38.57
39.05
37.95
38.13
39.5039.53
39.58 39.49
39.6039.7540.65
40.74
40.74
40.74
40.78
SC
40.86
40.98
40.86
40.98 40.83
GRT.39.429
40.98
40.98
40.98 40.98 40.98
CLEAN
OUT
10" PVC10" PVC
12" PVC
40.90
8
40.98 40.90
40.98 40.98
40.98
40.98
40.98
40.74
40.7440.45
40.56
40.62
40.86
12" PVC
39.13
40.10
42.32X
42.47
42.26
42.1442.38 42.88 42.9342.5242.31
42.88 43.0542.6442.43 42.26
42.7442.80 42.64
42.64
41.91
41.96
42.08
MEG
40.35
EDGE OF PAVEMENT
TO BE FLUSH WITH
SIDEWALK
40.52
40.52
40.52
40.52
40.29
40.16
40.52
40.52
2%2%2%NORTH40200
SCALE: 1" = 20'
LEGEND
= SPOT ELEVATION
= GRADE BREAK
= SURFACE FLOW
40.89
SC = SAWCUT EXISTING
EOP AND MATCH TO
LINE AND GRADE
AT EDGE OF PAVEMENT
STORM SEWER SCHEDULE
STRUCTURE
NUMBER
STRUCTURE
TYPE
TOP OF
CASTING EL.
PIPE
LENGTH
(FEET)
PIPE
SIZE /
TYPE
PERCENT
SLOPEIN
INVERT ELEVATIONS
1
2
OUT
DOWNSTREAM
STRUCTURE
3
4
63'15" RCP 1.00%2 TYPE C 40.44 33.04
32'18" RCP 0.30%3 TYPE C 39.70 32.41
32.32
*TIE INTO EXISTING STS 18" STUB
*
*REMOVE EXISTING TYPE P-6 INLET AND REPLACE WITH TYPE VG INLET*
**TYPE VG 38.25
32.41 SW,SE
32.32
18" RCP
18" RCP
MATCH EXISTING GRADEMEG
5 45'10" PVC 2.00%6 10" YARD DRAIN 36.26
6 45'10" PVC 2.00%7 35.36
7 30'10" PVC 2.00%8 34.46
35.36
34.46
8 41'12" PVC 2.00%1 40.74 33.86CLEAN OUT 33.86
9 84'18" RCP 2.00%2 39.42 34.09
10" YARD DRAIN
10" YARD DRAIN 40.70
40.70
40.70
33.04
33.72 S
FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Feb. 15, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065GRADING PLANC5.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUPTYPE C
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTLOT 4
0.83 AC
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTS.R. 434 MICHAEL BLAKE BLVD.Z
PRIVATE
FIRE HYDRANT
ASSEMBLY
PRIVATE METER
BANK. CONTRACTOR
TO INSTALL 3/4" POLY
LINES TO EACH
TENANT SPACE
WM 8 PVC
EXISTING WM 8 PVC
TIE WM 8 PVC
TO EXIST. 8" STUB
6" DR18 FIRE
WM 2.0 PVC
8" PLUG
56 LF,SAN 8 PVC,2.00%
TIE TO EXISTING
SANITARY MH AT
INV. 31.89
SAN 6 PVC 1.00% MIN.
INV.
33.85
INV.
33.64INV.
33.53
INV.
33.40
INV.
33.51
C.O.
INV.33.50
C.O.
INV.
33.00
SANITARY TYPE I MH
RIM 40.38
INV. 33.00 NE,NW,SE
SAN 4 PVC1.00% MIN.SAN 4 PVC1.00% MIN.SAN 4 PVC1.00% MIN.SAN 4 PVCSAN 4 PVC1.00% MIN.8"X4" TEE
WM 6" PVC
FDC 6" DR18 FIRE
FIRE
ENTRY
6" DDCVA, 6'X3'
CONC. PAD.
8"X8" TEE
8"GATE VALVE
F.F. 41.00
CURBING TO BE
PAINTED YELLOW
AUTO TURN
SEMINOLE COUTY
LADDER TRUCK
RPZ B.F.P. W/ 2.0"
DOMESTIC METER
CLEARANCE BETWEEN
PIPES = 1.35'
34" HOSE BIBB
WM
3
/
4
"
P
V
C
4" GV6" GV
P.O.S.
CURBING TO BE
PAINTED YELLOW SIGN "NO
PARKING"
SIGN "NO
PARKING"
8"X6" TEE
6"x4" RED
RPZ B.F.P. W/ 1.0"
IRR. METER
13
C9.0
13
C9.0
13
C9.0
8"x6" TEE
6" GV
4" DR18 FIRE (FDC LINE)NORTH40200
SCALE: 1" = 20'
PIPE CROSSING NOTE:
THE GENERAL CONTRACTOR SHALL LOCATE BELL AND
SPIGOT OF EACH PIPE SEGMENT AWAY FROM PIPE
CROSSING. PIPE CROSSING ELEVATIONS REPRESENT
OUTSIDE WALL THICKNESSES AND DOES NOT INCLUDE
BELL AND SPIGOT WIDENINGS.
MAINTAIN A MINIMUM OF 3 FEET OF COVER OVER ALL
PROPOSED WATER, WASTEWATER, AND RECLAIMED
WATER LINES. ALL EXISTING UTILITIES HAVE BEEN
FIELD VERIFIED AT ALL POINTS OF CONNECTION TO
AND AT ALL AREAS OF CONFLICT WITH MAINS.
ALL SANITARY AND WATER LINES ON PROPERTY
SHALL BE INSPECTED BY THE BUILDING DEPARTMENT.
UTILITY NOTE:FIRE FLOW CALCULATION
BUILDING TYPE:
BUILDING FLOOR AREA:
MINIMUM REQUIRED FIRE FLOW (NFPA1 TABLE 18.5.4.3)
NUMBER OF FIRE HYDRANT PROVIDED:
MAXIMUM FIRE HYDRANT FIRE FLOW CAPACITY
(NFPA 1 TABLE 18.5.4.3):
V-B
7,200 SF
1,500 GPM
1 HYDRANTS
1 HYDRANTS AT < 250' = 1,500 GPM
TOTAL FIRE FLOW 1,500 GPM
FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Mar. 14, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065UTILITY PLANC6.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUP:37.8Steering Angle
8.00 24.00
8.50
8.50
6.0
SEMINOLE CO LADDER TRUCK
feet
:
:
:
Width
Track
Lock to Lock Time
41.20
AUTO TURN
SEMINOLE COUNTY FIRE NOTES:
1)FIRE DEPARTMENT ACCESS ROADS PROVIDED AT THE START OF A PROJECT AND SHALL BE MAINTAINED
THROUGHOUT CONSTRUCTION. (NFPA 1, 16.1.4).
2)A WATER SUPPLY FOR FIRE PROTECTION, EITHER TEMPORARY OR PERMANENT, SHALL BE MADE AVAILABLE
AS SOON AS COMBUSTIBLE MATERIAL ACCUMULATES. THIS APPLIES TO BOTH COMMERCIAL AND
RESIDENTIAL DEVELOPMENTS. (NFPA 1, 16.4.3.1).
3)WHERE UNDERGROUND WATER MAINS AND HYDRANTS ARE TO BE PROVIDED, THEY SHALL BE INSTALLED,
COMPLETED, AND IN SERVICE PRIOR TO CONSTRUCTION WORK. (NFPA 1, 16.4.3.1.3).
4)FIRE FLOW TESTING SHALL BE PERFORMED IN ACCORDANCE WITH NFPA 291, RECOMMENDED PRACTICE
FOR FIRE FLOW TESTING.
5)A 36 IN. CLEAR SPACE SHALL BE MAINTAINED AROUND THE CIRCUMFERENCE OF FIRE HYDRANTS AND A
CLEAR SPACE OF NOT LESS THAN 60 IN. (1524 MM) SHALL BE PROVIDED IN FRONT OF EACH HYDRANT
CONNECTION HAVING A DIAMETER GREATER THAN 21⁄2 IN. NFPA 1, 18.5.7.
6)HYDRANT SHALL BE MARKED WITH A BLUE REFLECTOR THAT IS PLACED’6’’ IN THE ROADWAY IN
ACCORDANCE WITH NFPA 1, CHAPTER 18.5.10 (2015).
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTLOT 4
0.83 AC
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTS.R. 434 MICHAEL BLAKE BLVD.Z
PRIVATE
FIRE HYDRANT
ASSEMBLY
PRIVATE METER
BANK. CONTRACTOR
TO INSTALL 3/4" POLY
LINES TO EACH
TENANT SPACE
WM 8 PVC
EXISTING WM 8 PVC
TIE WM 8 PVC
TO EXIST. 8" STUB
6" DR18 FIRE
WM 2.0 PVC
8" PLUG
56 LF,SAN 8 PVC,2.00%
TIE TO EXISTING
SANITARY MH AT
INV. 31.89
SAN 6 PVC 1.00% MIN.
INV.
33.85
INV.
33.64INV.
33.53
INV.
33.40
INV.
33.51
C.O.
INV.33.50
C.O.
INV.
33.00
SANITARY TYPE I MH
RIM 40.38
INV. 33.00 NE,NW,SE
SAN 4 PVC1.00% MIN.SAN 4 PVC1.00% MIN.SAN 4 PVC1.00% MIN.SAN 4 PVCSAN 4 PVC1.00% MIN.8"X4" TEE
WM 6" PVC
FDC 6" DR18 FIRE
FIRE
ENTRY
6" DDCVA, 6'X3'
CONC. PAD.
8"X8" TEE
8"GATE VALVE
F.F. 41.00
CURBING TO BE
PAINTED YELLOW
AUTO TURN
SEMINOLE COUTY
LADDER TRUCK
RPZ B.F.P. W/ 2.0"
DOMESTIC METER
CLEARANCE BETWEEN
PIPES = 1.35'
34" HOSE BIBB
WM
3
/
4
"
P
V
C
4" GV6" GV
P.O.S.
CURBING TO BE
PAINTED YELLOW SIGN "NO
PARKING"
SIGN "NO
PARKING"
8"X6" TEE
6"x4" RED
RPZ B.F.P. W/ 1.0"
IRR. METER
13
C9.0
13
C9.0
13
C9.0
8"x6" TEE
6" GV
4" DR18 FIRE (FDC LINE)NORTH40200
SCALE: 1" = 20'
PIPE CROSSING NOTE:
THE GENERAL CONTRACTOR SHALL LOCATE BELL AND
SPIGOT OF EACH PIPE SEGMENT AWAY FROM PIPE
CROSSING. PIPE CROSSING ELEVATIONS REPRESENT
OUTSIDE WALL THICKNESSES AND DOES NOT INCLUDE
BELL AND SPIGOT WIDENINGS.
MAINTAIN A MINIMUM OF 3 FEET OF COVER OVER ALL
PROPOSED WATER, WASTEWATER, AND RECLAIMED
WATER LINES. ALL EXISTING UTILITIES HAVE BEEN
FIELD VERIFIED AT ALL POINTS OF CONNECTION TO
AND AT ALL AREAS OF CONFLICT WITH MAINS.
ALL SANITARY AND WATER LINES ON PROPERTY
SHALL BE INSPECTED BY THE BUILDING DEPARTMENT.
UTILITY NOTE:FIRE FLOW CALCULATION
BUILDING TYPE:
BUILDING FLOOR AREA:
MINIMUM REQUIRED FIRE FLOW (NFPA1 TABLE 18.5.4.3)
NUMBER OF FIRE HYDRANT PROVIDED:
MAXIMUM FIRE HYDRANT FIRE FLOW CAPACITY
(NFPA 1 TABLE 18.5.4.3):
V-B
7,200 SF
1,500 GPM
1 HYDRANTS
1 HYDRANTS AT < 250' = 1,500 GPM
TOTAL FIRE FLOW 1,500 GPM
FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Mar. 14, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065UTILITY PLANC6.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUP:37.8Steering Angle
8.00 24.00
8.50
8.50
6.0
SEMINOLE CO LADDER TRUCK
feet
:
:
:
Width
Track
Lock to Lock Time
41.20
AUTO TURN
SEMINOLE COUNTY FIRE NOTES:
1)FIRE DEPARTMENT ACCESS ROADS PROVIDED AT THE START OF A PROJECT AND SHALL BE MAINTAINED
THROUGHOUT CONSTRUCTION. (NFPA 1, 16.1.4).
2)A WATER SUPPLY FOR FIRE PROTECTION, EITHER TEMPORARY OR PERMANENT, SHALL BE MADE AVAILABLE
AS SOON AS COMBUSTIBLE MATERIAL ACCUMULATES. THIS APPLIES TO BOTH COMMERCIAL AND
RESIDENTIAL DEVELOPMENTS. (NFPA 1, 16.4.3.1).
3)WHERE UNDERGROUND WATER MAINS AND HYDRANTS ARE TO BE PROVIDED, THEY SHALL BE INSTALLED,
COMPLETED, AND IN SERVICE PRIOR TO CONSTRUCTION WORK. (NFPA 1, 16.4.3.1.3).
4)FIRE FLOW TESTING SHALL BE PERFORMED IN ACCORDANCE WITH NFPA 291, RECOMMENDED PRACTICE
FOR FIRE FLOW TESTING.
5)A 36 IN. CLEAR SPACE SHALL BE MAINTAINED AROUND THE CIRCUMFERENCE OF FIRE HYDRANTS AND A
CLEAR SPACE OF NOT LESS THAN 60 IN. (1524 MM) SHALL BE PROVIDED IN FRONT OF EACH HYDRANT
CONNECTION HAVING A DIAMETER GREATER THAN 21⁄2 IN. NFPA 1, 18.5.7.
6)HYDRANT SHALL BE MARKED WITH A BLUE REFLECTOR THAT IS PLACED’6’’ IN THE ROADWAY IN
ACCORDANCE WITH NFPA 1, CHAPTER 18.5.10 (2015).
TYPICAL CONCRETE SIDEWALK DETAIL
N.T.S.
A
SECTION A-A
PLAN VIEW
EXTEND JOINT FILLER FULL DEPTH OF SIDEWALK
5.0'5.0'5.0'5.0'
B
5.0'
4" (TYP.)
5.0'
4" (TYP.)SECTION B-B
VARIES
B
NOTE:
PROVIDE 1/2" EXPANSION JOINT
BETWEEN SIDEWALK AND ALL FIXED
OBJECTS.
4" AGGREGATE BASE COURSE COMPACTED TO
90% STD. PROCTOR (TYP.)
1/2" RADIUS TOOLED JOINT OR 1"
DEEP SAWED JOINT (TYP.)
1/4" THICKNESS PREMOLDED EXPANSION JOINT FILLER
SPACED @ 35' O.C. MAX.
SLOPE 14"/FTMAX.
SEE TYPICAL
PAVEMENT
SECTION
SECTION B-B (THICKENED EDGE)
4"8"10"6"6'-0"
4" (TYP.)
A
1/2" R
(TYP.)SLOPE 1/4"/
FT. MAX.
4,000 PSI
CONCRETE
MIN. (TYP)
1/2" R
(TYP.)
ALL SIDEWALKS TO COMPLY WITH
FDOT INDEX 310
THERMOPLASTIC PAINT
PER FDOT SPECIFICATIONS
DIRECTIONAL ARROW
1'-6"
2'
1'-6"5'-6"2'-6"1'-6"2'-6"2'-6"
1'-6"
1'-6"
2'-0"
DIRECTIONAL ARROW DETAILS
N.T.S.
SIGN TO BE PLACED
AT ABOUT THE
LEADING/
TRANSVERSE LINES
OF THE CROSSWALK
PER THE SITE PLAN
4' MIN.
(TYP.)
12" WHITE STRIPE
SEE SITE PLAN
VARIES (6' MIN.)(SEE SITE PLAN)SIGN TO BE PLACED AT
ABOUT THE LEADING/
TRANSVERSE LINES OF
THE CROSSWALK PER
THE SITE PLAN
PRIVATE CROSSWALK STRIPING DETAIL
N.T.S.
TYPICAL CURB
AND GUTTER
NOTE:
1.MARKINGS FOR STREET SHALL BE ACCORDING TO LOCAL CODE
REQUIREMENTS AND AS OUTLINED IN SECTION 3B.18 OF THE MANUAL
ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND
HIGHWAYS.
2.ALL STRIPING IS TO BE THERMOPLASTIC PER FDOT SPECIFICATIONS.
12" WHITE STRIPE
BLUE PAVEMENT
REFLECTOR (LOCATE IN
MIDDLE OF LANE)
PAVEMENT
CURB
FIRE HYDRANT /
FIRE DEPT. CONNECTION
3'-5'
PAVEMENT MARKING AT FIRE HYDRANT / FDC DETAIL
N.T.S.
RIGID (PORTLAND CEMENT CONCRETE) PAVEMENT DESIGN SHOULD FOLLOW SEMINOLE COUNTY SPECIFICATIONS FOR
P.C.CONC.
12" STABILIZED SUBGRADE
2.0" FDOT SP-9.5
8" BASE COURSE
SEE NOTES #3 THRU #4
SEE NOTE #5
SEE NOTES #1 & #2
1. THE SUBGRADE SHOULD MEET A MINIMUM LBR OF 40 (STABILIZED
SUBGRADE). THE EXISTING SANDY SOILD AND RECOMMENDED
IMPORTED FILL WILL LIKELY POSSESS A LBR OF 20 TO 30.
THEREFORE, IN ORDER TO INCREASE THE BEARING VALUE, SHELL,
LIMEROCK, CRUSHED CONCRETE, LOW PLASTICITY CLAYEY SANDS
OR ANOTHER ACCEPTABLE PRODUCT WOULD NEED TO BE
BLENDED WITH THESE SANDS. THE STABILIZED SUBGRADE SHOULD
BE A MINIMUM DEPTH OF 12 INCHES AND COMPACTED TO A
MINIMUM DENSITY OF 98% OF THE MODIFIED PROCTOR MAXIMUM
DRY DENSITY.
2. COMPACTION TESTING OF THE SUBGRADE SHOULD BE
PERFORMED TO FULL DEPTH AT A FREQUENCY OF AT LEAST ONE
(1) TEST PER 5,000 SQUARE FEET, OR EVERY 250 LINEAL FEET OF
ROADWAY, WHICHEVER IS GREATER. COMPACTION TESTING OF
THE STABILIZED SUBGRADE SHOULD BE PERFORMED AT FULL
DEPTH AT A FREQUENCY OF AT LEAST ONE (1) TEST PER 10,000
SQUARE FEET, OR A MINIMUM OF 3 TESTS, WHICHEVER IS GREATER.
3. ALL BASE MATERIALS SHOULD BE COMPACTED TO A MINIMUM
DENSITY OF 98% MPMDD. CRUSHED CONCRETE, LIMEROCK, AND
SHELL BASES SHOULD BE A MINIMUM LBR OF 100 AND COMPLY
WITH THE LATEST EDITION OF THE FDOT ROAD AND BRIDGE
CONSTRUCTION SPECIFICATIONS.
4. TRAFFIC SHOULD NOT BE ALLOWED ON THE SUBGRADE AS THE
BASE IS PLACED TO AVOID RUTTING. BEFORE PAVING, THE BASE
SHOULD BE CHECKED FOR SOUNDNESS.
5. THE ASPHALTIC CONCRETE SHOULD MEET STANDARD FDOT
MATERIAL REQUIREMENTS AND PLACEMENT PROCEDURES AS
OUTLINED IN THE LATEST EDITION OF THE FDOT ROAD AND BRIDGE
CONSTRUCTION SPECIFICATIONS, EXCEPT THAT THE ASPHALTIC
CONCRETE SHOULD BE COMPACTED TO A MINIMUM OF 96% OF THE
MARSHALL MAXIMUM LABORATORY UNIT WEIGHT OF SAMPLES
SECURED DAILY DURING PLACEMENT.
12"
ASPHALT PAVING
NTS
PUBLIC ROWS
(INCL. ROADS AND PARKING)
P.C.CONC.
12" STABILIZED SUBGRADE
1.5" FDOT SP-9.5
6" BASE COURSE
SEE NOTES #3 THRU #4
SEE NOTE #5
SEE NOTES #1 & #2
12"
ALLEYS,PARKING AREAS &
PRIVATE ROADS
NOTE: 1.5" THICKNESS IS FOR A SINGLE LIFT. IF THE
PAVEMENT WILL BE PLACED IN TWO LIFTS, THE TOTAL
THICKNESS SHOULD BE 2", WITH TWO 1" LIFTS
END OF CURB
PROFILE
PLAN
3'
FLARED END
6'20' R
GUTTER
TOP OF CURB
3'
TRANS.
EDGE OF PAVT.
1'
3'
TRANS.
STRAIGHT END
PROFILE
PLAN
3'
TRANS.
CURB AND GUTTER ENDINGS DETAIL
N.T.S.
GUTTER
TOP OF CURB
EDGE OF PAVT.
18" FACE OF CURBBACK OF CURB12"6"6"6"12"
1"
P.C. CONCRETE
18" CURB AND GUTTER DETAIL
N.T.S.
1/2" MIN. RADIUS
1" MAX. RADIUS
ASPHALTIC CONCRETE PAVING
SEE PAVING DETAILS FOR
PAVEMENT SECTIONS, SUBBASE,
SUBGRADE AND COMPACTION
REQUIREMENTS.
CONTRACTOR TO PROVIDE
PRIME COAT AND TACK
COAT TO FACE OF CURB
WHERE CURB CONTACTS
ASPHALT.
NOTE: GUTTER SLOPE TO MATCH
ADJACENT PAVEMENT,
TRAVERSE AND LONGITUDINAL.
1/2" MIN. RADIUS
1" MAX. RADIUS
NOTE:
1. PAVEMENT STOP BARS ARE TO BE THERMOPLASTIC WHITE PAINT. ALL SIGNS SHALL COMPLY WITH U.S. DEPARTMENT
OF TRANSPORTATION, FEDERAL HIGHWAY ADMINISTRATION'S "MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES", LOCAL
CODES AND AS SPECIFIED. MOUNT SIGNS TO POST IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
STOP BAR DETAIL
N.T.S.
CROSS WALK
4'-0"STOP BAR2'-0"EDGE OF PAVEMENT OF FACE OF CURBRESERVEDPARKING
VANACCESSIBLE
GROUND/PAVING
SURFACE 7'-0" (MIN)$250 FINE
NOTE: THE MIN. HEIGHT OF THE BOTTOM
OF THE LOWEST SIGN SHALL BE 7'-0".
F.S. 316.008
DECORATIVE POST
SIGN MOUNTING DETAIL
N.T.S.
CONCRETE PAVING
NTS
RIGID (PORTLAND CEMENT CONCRETE) PAVEMENT DESIGN SHOULD FOLLOW SEMINOLE COUNTY SPECIFICATIONS FOR
MINIMUM COMPRESSIVE STRENGTH. BASED ON OUR EXPERIENCE, A MINIMUM THICKNESS OF 6 INCHES CAN BE
USED FOR STANDARD DUTY APPLICATIONS AND A MINIMUM THICKNESS OF 7 INCHES SHOULD BE UTILIZED FOR HEAVY
DUTY APPLICATIONS. ANY STEEL REINFORCEMENT WITHIN THE CONCRETE PAVEMENT SHOULD BE DESIGNED BY THE
PROJECT CIVIL OR PAVEMENT ENGINEER. THE SUBGRADE SHOULD BE PREPARED TO ACHIEVE A MINIMUM LBR OF
30 TO A DEPTH OF 12 INCHES BELOW THE CONCRETE BASE ELEVATION. THE SUBGRADE SOILS SHOULD BE
COMPACTED TO A MINIMUM DENSITY OF 98% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY. TO AID IN THE
DESIGN OF THE ANTICIPATED CONCRETE PAVEMENT SECTIONS, A MODULUS OF SUBGRADE REACTION OF 100 PCI
(LBR 20 SANDS) SHOULD BE UTILIZED FOR THE LOW BEARING SANDS UNLESS STABILIZATION IS ADDED TO INCREASE
THE BEARING VALUE. IF THE SANDS ARE STABILIZED, A MODULUS VALUE OF 150 PCI CAN BE UTILIZED.
1
2
3
10 4
5
6
7
8
9
11
12 FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Feb. 15, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065GENERAL DETAILSHEET 1C7.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUP
NOTES:
*5'4"18'PARKING LOT STRIPING DETAILS
NTS
ACCESS ISLE5' (STD. ACCESSIBLE)
HANDICAP PARKING SIGNAGE18"12"6"SYMBOL ASDETAILED BELOW
6" BLUE
TYP.
6" WHITE STRIPING2'-0" O.C. (TYP)
1. ALL LETTERS ARE 1" SERIES "C". PER MUTCD.2. TOP PORTION OF SIGN SHALL HAVE REFLECTORIZED (ENGINEERINGGRADE) BLUE BACKGROUND WITH WHITE REFLECTORZED LEGEND ANDBORDER.
3. BOTTOM PORTION OF SIGN SHALL HAVE A REFLECTORIZED
(ENGINEERING GRADE) WHITE BACKGROUND WITH BLACK OPAQUE
LEGEND AND BORDER.
4. ONE (1) SIGN REQUIRED FOR EACH PARKING SPACE.
5. INSTALLATION HEIGHT OF SIGN SHALL BE IN ACCORDANCE WITH
SECTION 24-23 OF THE MANUAL ON UNIFORM TRAFFIC CONTROLDEVICES (MUTCD).
USE OF PAVEMENT SYMBOL IN HANDICAPPED PARKING
SPACES IS OPTIONAL. WHEN USED, THIS SYMBOL SHALLBE 3 TO 5 FEET HIGH AND WHITE IN COLOR.
12'
(TYP.)SIGN
12'9'
TYP.
WHEEL STOP
SILT BARRIER DETAIL
N.T.S.
INLET SEDIMENT FILTER
SECTION VIEW
-INSTALLED-
WITH OPTIONAL CURB INLET DAM
RIGID BYPASS
LOUVERS
BASIN BAG
CATCH BASIN
EXPANSION
RESTRAINT
CURB
CINCHING
CORDS
OPTIONAL CURB
INLET DAM
GRATE
RIGID BYPASSOUTLET HOLES
LIFTING STRAPSPECIFIER CHART
MODEL NO.CATCH BASIN ID
Inside Dimension
(inch x inch)
CURB DAM OPTION
(YES / NO)
FG-TB24 NO
YESFG-TB24D
FG-TB2436
FG-TB2436D
FG-TB36
FG-TB36D
24 x 24
24 x 24
24 x 36
24 x 36
36 x 36
36 x 36
NO
YES
NO
YES
NOTES:
1. FloGard T-Bag is manufactured from
woven monofilament polypropylene
fabric. Other materials available upon
request.
2. May be ordered with Fossil Rock oil
absorbent pouches installed.
3. Optional curb inlet dam available upon
request.
4. Periodic maintenance is required.
FloGard T-Bag should never be
allowed to fill beyond the top of the
bypass outlet louvers.
5. Appropriate lifting equipment should
be used when performing periodic
maintenance.
SHEET 1 OF 1DRAWING NO.FG-TB-0001 DATE JPR 09/01/06
P.O. Box 6419, Santa Rosa, CA 95406
Ph: 800.579.8819, Fax: 707.524.8186, www.kristar.com
KriStar Enterprises, Inc.
REV ECO 0002N/R
T-BAGf
TEMPORARY INLET PROTECTION DEVICE
d
FROM PUBLIC STREET.
MIN. 0.5% GRADE DOWN
MI
N
0
.
5
%
G
R
A
D
E
50'
M
I
N
I
M
U
M
20' MINI
M
U
M
HAR
D
S
U
R
F
A
C
E
PUB
LI
C
R
O
A
D
12" MINIMUM
GEOTEXTILE UNDERLINER
4"-6" CLEAN STONE
N.T.S.
CONSTRUCTION ENTRANCEGUTTER BUDDY
CURB INLET PROTECTION
N.T.S.
1'1'GUTTER BUDDY
DISTRIBUTED BY ACF
ENVIRONMENTAL
SIDEWALK
GUTTER
FLOW
CURB INLET
CURB
ROCK BAG
(TYP.)
N.T.S.
WITH WIRE SUPPORT
SEDIMENTATION / SILT FENCE
A-A-SECTION
WOVEN WIRE FENCEWITH SILT FENCE
COMPACTEDBACKFILL
6"EXTEND WIRE FENCE AMIN. OF 2" INTO TRENCH
6" X 6"TRENCH6"(MIN.)24"6"POSTS: STEEL T OR U TYPE.
FENCE: WOVEN WIRE, 14-1/2 GA., 6" MAX. MESH OPENING
GROUNDUNDISTURBED
FLOW
FINISH GRADE
FABRIC: IN ACCORDANCE WITH ASTM D 6461 LATEST EDITION.
5' MAX. C-C
COMPACTED BACKFILL
FLOW
ELEVATION
FLOW
FINISH
G
R
A
D
E
WOVEN WIRE FENCE
5' MAX. C-C
OR AS DICT
A
T
E
D
B
Y
A
A
5' MIN OVE
R
L
A
P
LOCAL REQ
U
I
R
E
M
E
N
T
S
60" MIN. STEEL POSTS (72" MIN. ON SLOPES
3H:1V OR GREATER), DRIVEN MIN. 20" INTO
GROUND (MIN. 24" ON SLOPES 3H:1V OR
GREATER).
EMBEDDED SILT FENCE
MATERIAL MIN. 6" INTO
GROUND W/ 6" LAID
ALONG BOTTOM OF
TRENCH. SOIL SLICING
IN ACCORDANCE WITH
ASTM D 6462 8.2.2 IS
ALSO ACCEPTABLE.
WHEN NECESSARY TO CONTINUE
FENCE, OVERLAP SILT FENCE
MATERIAL AND WOVEN WIRE FENCE
ACROSS TWO POSTS
SECURELY FASTEN OVERLAPPING ENDS OFSILT FENCE MATERIAL TO ADJACENT STAKESWITH THREE WIRE TIES OR OTHER
FASTENERS
OR AS DICT
A
T
E
D
B
Y
LOCAL REQU
I
R
E
M
E
N
T
S
SILT FENCE MATERIAL TO BE FASTENED
SECURELY TO WOVEN WIRE FENCE WITH
THREE TIES SPACED AT 30" ON CENTER
SILT FENCE MATERIAL
OVER WIRE FENCE
1. INSTALLATION SHALL COMPLY WITH ASTM D 6462 LATEST EDITION.2. ATTACH THE WOVEN WIRE FENCE TO EACH POST AND THE GEOTEXTILETO THE WOVEN WIRE FENCE (SPACED EVERY 30") WITH THREE WIRE TIES
OR OTHER FASTENERS, ALL SPACED WITHIN THE TOP 8" OF THE FABRIC.ATTACH EACH TIE DIAGONALLY 45 DEGREES THROUGH THE FABRIC, WITHEACH PUNCTURE AT LEAST 1" VERTICALLY APART. ALSO, EACH TIE
PLACED ON A POST SHOULD BE POSITIONED TO HANG ON A POST NIPPLEWHEN TIGHTENED TO PREVENT SAGGING.3. WHEN TWO SECTIONS OF SILT FENCE MATERIAL ADJOIN EACH OTHER,
THEY SHALL BE OVERLAPPED A MINIMUM OF 60" ACROSS TWO POSTS, ASSHOWN.
4. MAINTENANCE SHALL BE PERFORMED AS NOTED IN THE SWPPP. DEPTH
OF ACCUMULATED SEDIMENTS MAY NOT EXCEED ONE-HALF THE HEIGHTOF THE FENCE. MAINTENANCE CLEANOUT MUST BE CONDUCTED
REGULARLY TO PREVENT ACCUMULATED SEDIMENTS FROM REACHING
ONE-HALF THE HEIGHT OF THE SILT FENCE MATERIAL ABOVE GRADE.5. ALL SILT FENCE SHALL INCLUDE WIRE SUPPORT UNLESS THE STATIC
SLICING EQUIPMENT IS UTILIZED TO INSTALL THE FENCE PER DETAIL- "SILTFENCE INSTALLATION (SLICING METHOD)".6. WRAP APPROXIMATELY 6" OF FABRIC AROUND THE END POSTS AND
SECURE WITH 3 TIES.7. COMPACT THE SOIL IMMEDIATELY NEXT TO THE SILT FENCE FABRIC WITHTHE FRONT WHEEL OF THE TRACTOR, SKID STEER, OR ROLLER EXERTING
AT LEAST 60 POUNDS PER SQ. INCH. COMPACT THE UPSTREAM SIDEFIRST. COMPACT EACH SIDE TWICE FOR A TOTAL OF FOUR TRIPS.
8. ADD POST CAPS AS NEEDED BASED ON SITE CONDITIONS AND
APPLICABLE AGENCY REQUIREMENTS.
MATERIAL COVER
ATTACH THE WOVEN WIREFENCE TO EACH POSTWITH THREE WIRE TIES OROTHER FASTENERS(SEE NOTE 2)
N.T.S.
NOTES:
1. DETECTABLE WARNING SURFACE SHALL BE UTILIZED AT HAZARDOUS VEHICULAR AREAS
AND SHALL BE A CONTINUOUS SURFACE 36" WIDE AS MEASURED IN THE DIRECTION OF
THE RAMP.
2. DETECTABLE WARNING SURFACES SHALL CONSIST OF:
EXPOSED AGGREGATE, SUCH AS 58" ADA TRUNCATED DOME PAVERS.
3. DETECTABLE WARNING SURFACE MATERIAL SHALL CONTRAST IN COLOR AND TEXTURE
WITH THE ADJACENT WALKING SURFACES BY AT LEAST 70%. CONTRAST SHALL BE
DETERMINED BY THE DIFFERENCE IN LIGHT REFLECTANCE VALUE (LRV) OF EACH
MATERIAL.
ON-SITE ADA RAMPS
NTS
CURB RETURN RAMP IN-LINE RAMP FLARED RAMPSIDEWALK5' MIN.
5' MIN.6' MIN.1:12 MAX.
6" CURB
DETECTABLE WARNING
SURFACE, SEE NOTES
2' R. (TYP.)
1:12 MAX.
1:12 MAX.
DETECTABLE WARNING
SURFACE, SEE NOTES
6" CURB
2% MAX.
SIDEWALK
5' MIN.3'
DETECTABLE WARNING
SURFACE, SEE NOTES
6'
1:12
MAX.
1:10 MAX.
1:10 MAX.
6" CURB
6" CURBSIDEWALK 5' MIN.5' MIN.5' MIN.1
2
3
4
5
67 FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Feb. 15, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065GENERAL DETAILSHEET 2C8.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUPNOTE:
SURFACE STONE - FIRE DEPARTMENT ACCESS ROADS SHALL BE
DESIGNED AND MAINTAINED TO SUPPORT THE IMPOSED LOADS OF FIRE
APPARATUS AND SHALL BE PROVIDED WITH AN ALL-WEATHER DRIVING
SURFACE. NFPA 1, CHAPTER 18.2.3.4.2 (2015). VERIFY THAT STABILIZED
ROAD CAN HOLD 39 TONS.
CONCRETE STONE ENTRANCE DETAIL ON SHEET C8 INDICATES 15 FEET
ROAD WIDTH. FIRE DEPARTMENT ACCESS ROAD SHALL HAVE AN
UNOBSTRUCTED WIDTH OF NOT LESS THAN 20 FT IN ACCORDANCE WITH
THE SPECIFICATIONS OF NFPA 1, CHAPTER 18.2.3.4 (2015 EDITION).
W.S. DETAIL 6-9-00 BY DT
16" AB0VE PIPE
PIPE BEDDING UTILIZING SELECT COMMON FILL OR BEDDING ROCK IN ACCORDANCE
15" MAXIMUM/12" MINIMUM FOR PIPE DIAMETERS LESS THAN 24".
24" MAXIMUM/12" MINIMUM FOR PIPE DIAMETERS 24" AND LARGER
WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION.
ALL PIPES ARE TO BE INSTALLED WITH THE BELL FACING UPSTREAM TO THE DIRECTION(SEE NOTE 2)TRENCH BACKFILLW/ SIZE OF PIPE
VARIES
SEE NOTE 4
PIPE O.D.COMMON FILL
12" (TYP.)
FINISHED GRADETRENCH WIDTH
SELECT COMMON
FILL
INITIAL
BACKFILL
(SEE NOTE 1)HAUNCHING 12" LIFTS MAXIMUMUNDISTURBED EARTH
(SEE NOTE 3)
WITH TYPE "A" BEDDING AND TRENCHING DETAIL MAY BE REQUIRED AS DIRECTED
BY UTILITIES.
OF THE FLOW.
FINAL RESTORATION IN IMPROVED AREAS SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
REGULATIONS OF THE GOVERNING AGENCIES.
NOTES:
1.
2.
3.
4.
5.
6.
7.
TRENCH BACKFILL: COMMON FILL COMPACTED TO 95% OF THE MAXIMUM DENSITY, PER
AASHTO T-180. DENSITY TEST SHALL BE PROVIDED TO THE CITY BY AN APPROVED LAB.
BEDDING & TRENCHING - TYPE B
NTS
TRENCH BACKFILL: COMMON FILL COMPACTED TO 95% OF THE MAXIMUM DENSITY, PER
TYPE "A" BEDDING MATERIAL SHALL CONFORM TO FDOT NO. 57 AGGREGATE.
15" MAXIMUM/12" MINIMUM FOR PIPE DIAMETER LESS THAN 24".
WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION.
ALL PIPE TO BE INSTALLED WITH BELL FACING UPSTREAM TO THE DIRECTION OF THE FLOW.
BEDDING DEPTH SHALL BE A 4" MINIMUM FOR PIPE DIAMETERS UP TO 12" AND 6" MINIMUM(SEE NOTE 2)TRENCH BACKFILL12" LIFTS MAXIMUMW/ SIZE OF PIPE
VARIES
SEE NOTE 4
PIPE O.D.COMMON FILL
BEDDING MATERIAL
12" (TYP.)
UNDISTURBED EARTH
FINISHED GRADETRENCH WIDTH
SELECT COMMON
FILL
INITIAL
BACKFILL (SEENOTE 1)(SEENOTE 3)HAUNCHING
BEDDING(SEE NOTES 7 & 8)
AASHTO T-180. DENSITY TEST SHALL BE PROVIDED TO THE CITY BY AN APPROVED LAB.
24" MAXIMUM/12" MINIMUM FOR PIPE DIAMETER 24" AND LARGER.
FOR PIPE DIAMETER 16" AND LARGER.
DEPTH FOR REMOVAL OF UNSUITABLE MATERIAL SHALL GOVERN DEPTH OF BEDDING ROCK
BELOW THE PIPE. UTILITIES SHALL DETERMINE (IN THE FIELD) THE REQUIRED REMOVAL OF
UNSUITABLE MATERIAL TO REACH SUITABLE FOUNDATION.
FINAL RESTORATION IN IMPROVED AREAS SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
REGULATIONS OF THE GOVERNING AGENCIES.
NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
BEDDING & TRENCHING - TYPE A
NTS
PIPE JOINT RESTRAINT DETAIL
NTS
1
2
3
11 4
5
9
10
13 6
7
812 FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Mar. 14, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065WATER DETAILSHEETC9.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUPDOMESTICFIRE
W.S. DETAIL 6-9-00 BY DT
16" AB0VE PIPE
PIPE BEDDING UTILIZING SELECT COMMON FILL OR BEDDING ROCK IN ACCORDANCE
15" MAXIMUM/12" MINIMUM FOR PIPE DIAMETERS LESS THAN 24".
24" MAXIMUM/12" MINIMUM FOR PIPE DIAMETERS 24" AND LARGER
WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION.
ALL PIPES ARE TO BE INSTALLED WITH THE BELL FACING UPSTREAM TO THE DIRECTION(SEE NOTE 2)TRENCH BACKFILLW/ SIZE OF PIPE
VARIES
SEE NOTE 4
PIPE O.D.COMMON FILL
12" (TYP.)
FINISHED GRADETRENCH WIDTH
SELECT COMMON
FILL
INITIAL
BACKFILL
(SEE NOTE 1)HAUNCHING 12" LIFTS MAXIMUMUNDISTURBED EARTH
(SEE NOTE 3)
WITH TYPE "A" BEDDING AND TRENCHING DETAIL MAY BE REQUIRED AS DIRECTED
BY UTILITIES.
OF THE FLOW.
FINAL RESTORATION IN IMPROVED AREAS SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
REGULATIONS OF THE GOVERNING AGENCIES.
NOTES:
1.
2.
3.
4.
5.
6.
7.
TRENCH BACKFILL: COMMON FILL COMPACTED TO 95% OF THE MAXIMUM DENSITY, PER
AASHTO T-180. DENSITY TEST SHALL BE PROVIDED TO THE CITY BY AN APPROVED LAB.
BEDDING & TRENCHING - TYPE B
NTS
TRENCH BACKFILL: COMMON FILL COMPACTED TO 95% OF THE MAXIMUM DENSITY, PER
TYPE "A" BEDDING MATERIAL SHALL CONFORM TO FDOT NO. 57 AGGREGATE.
15" MAXIMUM/12" MINIMUM FOR PIPE DIAMETER LESS THAN 24".
WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION.
ALL PIPE TO BE INSTALLED WITH BELL FACING UPSTREAM TO THE DIRECTION OF THE FLOW.
BEDDING DEPTH SHALL BE A 4" MINIMUM FOR PIPE DIAMETERS UP TO 12" AND 6" MINIMUM(SEE NOTE 2)TRENCH BACKFILL12" LIFTS MAXIMUMW/ SIZE OF PIPE
VARIES
SEE NOTE 4
PIPE O.D.COMMON FILL
BEDDING MATERIAL
12" (TYP.)
UNDISTURBED EARTH
FINISHED GRADETRENCH WIDTH
SELECT COMMON
FILL
INITIAL
BACKFILL (SEENOTE 1)(SEENOTE 3)HAUNCHING
BEDDING(SEE NOTES 7 & 8)
AASHTO T-180. DENSITY TEST SHALL BE PROVIDED TO THE CITY BY AN APPROVED LAB.
24" MAXIMUM/12" MINIMUM FOR PIPE DIAMETER 24" AND LARGER.
FOR PIPE DIAMETER 16" AND LARGER.
DEPTH FOR REMOVAL OF UNSUITABLE MATERIAL SHALL GOVERN DEPTH OF BEDDING ROCK
BELOW THE PIPE. UTILITIES SHALL DETERMINE (IN THE FIELD) THE REQUIRED REMOVAL OF
UNSUITABLE MATERIAL TO REACH SUITABLE FOUNDATION.
FINAL RESTORATION IN IMPROVED AREAS SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
REGULATIONS OF THE GOVERNING AGENCIES.
NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
BEDDING & TRENCHING - TYPE A
NTS
PIPE JOINT RESTRAINT DETAIL
NTS
1
2
3
11 4
5
9
10
13 6
7
812 FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Mar. 14, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065WATER DETAILSHEETC9.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUPDOMESTICFIRE
PRECAST CONCRETE MANHOLE
PLAN AND SECTION
APPROVED CONCENTRIC CONE DESIGN MAY BE USED AS AN ALTERNATIVE. CONNECTION DETAILS. 24" OR MORE ABOVE THE INVERT OF THE MANHOLE. SEE MANHOLE
DROP CONNECTIONS ARE REQUIRED WHENEVER INVERT OF INFLUENT SEWER IS
MANHOLE SHOWN IS FOR SEWER SIZE 8" THRU 24"
NOTES:
D
4' 0"
2' 0"
DETAILS
SEE MANHOLECONNECTION
CONCRETE BENCHINGTROWEL-FINISHED
BENCHING PER SPECIFICATIONS
1"12"
APPROVED BY THE CITY.THE ENGINEER ANDDETAIL TO BE DESIGNED BYREINFORCEMENT AND JOINT
BEDDING ROCK
CAST-IN-PLACE CONCRETE BASE
9"
9"
EPOXY COAL TAR COATINGS PER SPECIFICATIONS
UNPAVED AREAS.ELEVATIONS SHOWN INPAVED AREAS & ATSET COVERS FLUSH IN
3'-0" MAX.
1'-6" MIN.
5"
3.
CONCRETE BASE
SLOP
E
SL
O
P
E
SLOPESLOPE2.
1.
SQUEEZE-OUT
BE REMOVED)
(WRAPPER TO
WRAPPERPROTECTIVESEALER WITH
PLASTIC JOINT
PRE-MOLDED
JOINT SURFACESPRE-PRIMED
OUTSIDE WALL
0.8 DVARIES AS REQ'DPRECAST MONOLITHIC BASE
9"
9"
MIN.
6"
2" MIN.
8" MIN.SQUEEZE-OUTJOINT WITH
COMPLETED
4 COURSES (MAX.)
2 COURSES OF BRICK (MIN.)
FRAMES BEDDED IN MORTAR
(SEE STANDARD DETAIL)
MANHOLE FRAME & COVER
5" MIN.REQ'DVARIES ASVARIES ASJOINT SURFACESPRE-PRIMED
INSIDE WALLREQ'DN.T.S.
6" MINIMUM
SEWER MAIN
SIZE VARIES
"DOWNSTREAM"
LOT LINE
AS REQUIRED
NOTE:
"Y" BRANCH WITH SPUR
30° CURVE
SEWER MAIN
SIZE VARIES
GROUND LEVEL
SERVICE CONNECTION DETAILS
SHOWN IS FOR A DOUBLE PVC
SERVICE A SINGLE WYE WOULD
BE USED FOR A SINGLE SERVICE 5' MAX6"X 4' DOUBLE WYE WITH 6"
CLEAN OUT INSTALLED TO 3'
ABOVE GROUND SURFACE
3' MIN.3' MINClean Out is to
be placed at
ground level after
TV inspection &
acceptance by the
utility department.
NON-PAVED AREAS
EASEMENT, PROPERTY
OR RIGHT-OF-WAY LINE
SEWER BRANCH WYE
FLOW
MINIMUM SLOPE
6" SANITARY LATERAL
45° BEND
PROVIDE CLEAN-OUT ON SEWER
LATERALS AT UTILITY EASEMENT
LIMITS. SEE PLANS
18" x 18" x 6" CONCRETE
COLLAR; (2) #4 BARS CONTINUOUS
AND (4) #4 BARS DIAGONAL
12" MAXIMUM WITHIN
RIGHT-OF-WAY LINE
34" EXPANSION
JOINT AROUND CAP
FLUSH WITH SLAB
CLEANOUT COVERS IN PAVED
AREAS SHALL BE TRAFFIC RATED.
1
2
3
13 4
5
10
11
12 6
4
8
9 FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Feb. 15, 2019FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065SANITARY SEWERDETAIL SHEETC9.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUP
LOT 40.83 ACsheet numberproject numberREVISION SCHEDULEDATEDESCRIPTIONissue datedrawn byapproved byWMWW.BHM.US.COSMB/MJRAJB/BLS0JLC 18.0245.00Blake Lawrence SuddethP.E. #: 69060JLC&OJoseph, Lawrence & CoConsulting Engineers1180 Harwood ave., suite 3000Altamonte Springs, Florida 32714Tel: 321.972.4466www.jlceng.comCA No. 28730BHM ARCHITECTURE, INC.MAIL ONLY: 478 E ALTAMONTE DR.,SUITE 108 PMB 264ALTAMONTE SPRINGS, FL 32701-4622PHONE: 407.333.2005 LICENSE # AAC000233THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF BHM ARCHITECTURE, INC. AND ARE ISSUED ONLY FOR THE SPECIFICPROJECT NOTED ON THESE DRAWINGS. ANY REPRODUCTION AND/OR REDISTRIBUTION WITHOUT THE EXPRESSED WRITTEN CONSENT OFBHM ARCHITECTURE, INC. IS PROHIBITED BY LAW. TO THE BEST OF THE ARCHITECT'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONSCOMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE SAFETY STANDARDS.RETAIL BUILDINGSR 434 & Tuskawilla RoadWinter Springs, Florida2018.00511-16-18PERMIT SETE1.1SITE PLANELECTRICALNSITE PLAN - ELECTRICAL1Scale: 1" = 10'-0"REFERENCE NOTES:GENERAL NOTES:
LOT 40.83 ACsheet numberproject numberREVISION SCHEDULEDATEDESCRIPTIONissue datedrawn byapproved byWMWW.BHM.US.COSMB/MJRAJB/BLS0JLC 18.0245.00Blake Lawrence SuddethP.E. #: 69060JLC&OJoseph, Lawrence & CoConsulting Engineers1180 Harwood ave., suite 3000Altamonte Springs, Florida 32714Tel: 321.972.4466www.jlceng.comCA No. 28730BHM ARCHITECTURE, INC.MAIL ONLY: 478 E ALTAMONTE DR.,SUITE 108 PMB 264ALTAMONTE SPRINGS, FL 32701-4622PHONE: 407.333.2005 LICENSE # AAC000233THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF BHM ARCHITECTURE, INC. AND ARE ISSUED ONLY FOR THE SPECIFICPROJECT NOTED ON THESE DRAWINGS. ANY REPRODUCTION AND/OR REDISTRIBUTION WITHOUT THE EXPRESSED WRITTEN CONSENT OFBHM ARCHITECTURE, INC. IS PROHIBITED BY LAW. TO THE BEST OF THE ARCHITECT'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONSCOMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE SAFETY STANDARDS.RETAIL BUILDINGSR 434 & Tuskawilla RoadWinter Springs, Florida2018.00511-16-18PERMIT SETE1.2SITE PLANPHOTOMETRICSNSITE PLAN - PHOTOMETRICS1Scale: 1" = 10'-0"Luminaire ScheduleSymbolQtyLabelArrangementTotal Lamp LumensLLFDescription6WLASINGLEN.A.0.950111L-2-20LA-NW5SLD4bSINGLEN.A.0.950CXFxx80-G2-4N5-16Calculation SummaryLabelCalcTypeUnitsAvgMaxMinAvg/MinMax/MinParking & Drive AreaIlluminanceFc2.899.80.214.4549.00Property LineIlluminanceFc0.421.00.0N.A.N.A.Strefront and PatioIlluminanceFc1.873.30.63.125.50SITE LIGHT FIXTURE SCHEDULE
sheet numberproject numberREVISION SCHEDULEDATEDESCRIPTIONissue datedrawn byapproved byWMWW.BHM.US.COSMB/MJRAJB/BLS0JLC 18.0245.00Blake Lawrence SuddethP.E. #: 69060JLC&OJoseph, Lawrence & CoConsulting Engineers1180 Harwood ave., suite 3000Altamonte Springs, Florida 32714Tel: 321.972.4466www.jlceng.comCA No. 28730BHM ARCHITECTURE, INC.MAIL ONLY: 478 E ALTAMONTE DR.,SUITE 108 PMB 264ALTAMONTE SPRINGS, FL 32701-4622PHONE: 407.333.2005 LICENSE # AAC000233THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF BHM ARCHITECTURE, INC. AND ARE ISSUED ONLY FOR THE SPECIFICPROJECT NOTED ON THESE DRAWINGS. ANY REPRODUCTION AND/OR REDISTRIBUTION WITHOUT THE EXPRESSED WRITTEN CONSENT OFBHM ARCHITECTURE, INC. IS PROHIBITED BY LAW. TO THE BEST OF THE ARCHITECT'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONSCOMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE SAFETY STANDARDS.RETAIL BUILDINGSR 434 & Tuskawilla RoadWinter Springs, Florida2018.00511-16-18PERMIT SETE1.3SITE LIGHTINGCUTSHEETS17FT. MOUNTING HEIGHT POLE DETAIL3Scale: Not to ScaleFIXTURE TYPE 'B' & 'C'1No ScaleFIXTURE TYPE 'SLA', 'SLB' & 'SLD'2No Scale
sheet numberproject numberTHESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF BHM ARCHITECTURE, INC. AND ARE ISSUED ONLY FOR THE SPECIFIC PROJECT NOTED ON THESEDRAWINGS. ANY REPRODUCTION AND/OR REDISTRIBUTION WITHOUT THE EXPRESSED WRITTEN CONSENT OF BHM ARCHITECTURE, INC. IS PROHIBITED BY LAW. TO THEBEST OF THE ARCHITECT'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRESAFETY STANDARDS.Winter Springs, FloridaRETAIL BUILDINGSR 434 & Michael Blake BlvdREVISION SCHEDULEDATEDESCRIPTIONissue date drawn by approved by0A0.0COVER SHEETRMH RMHWMW W . B H M . US.C OForJDBS Winter Springs, LLCAESTHETIC REVIEW SUBMITTALBHM ARCHITECTURE, INC.MAIL ONLY: 478 E ALTAMONTE DR.,SUITE 108 PMB 264ALTAMONTE SPRINGS, FL 32701-4622PHONE: 407.333.2005 LICENSE # AAC000233RETAIL BUILDINGSR 434 & Michael Blake BlvdWinter Springs, Florida2018.00510-29-18AESTHETIC REVEWCamala McCarter HogueAR-0009533AndMONUMENT SIGN
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTONLYONLYONLYLOT 4
0.83 AC
LOT 3
0.67 AC
STARBUCKS
2,500 SF RTONLYONLYONLYS.R. 434 MICHAEL BLAKE BLVD.7,200 SF
60'18'3.32'18 9
120'
18'18'22'18'6'9'12'12.55'
15.39'
9 9'
1118'22'4
18'
3'R.
A
24'10'R.5'10'7'11'
9'22'
5'
3'R.3'R.3'R.10'R.1
0
'
R
.
1
0
'
R
.
3'3'6'5'20'9'3'R.12'12.7'B C
C
B
B
B
D
D
D
D
D
L
E
F
G
HREMOVE 107LF OF EXISTING CURB AND GUTTERI
I
I
J
J
K
M
9'
SWSL/24"
SWSL/12"
SWSL/4"
SWSL/4"
SWSL/12"
N
EDGE OF PAVEMENT
TO BE FLUSH WITH
SIDEWALK
CURBED
SIDEWALK
O
O
P 10'R.9'
15.31'17.42'13.56'M
6'6'FORREVISIONSDATENO.SHEET DESIGNER:PRJ. MGR:JOB #:CHECKED:ENGINEER ENGINEER:RECORD DRAWINGTHIS RECORD DRAWING IS BASED ON THE RESULTS OF LIMITEDPERIODIC FIELD OBSERVATIONS DURING CONSTRUCTION, AREVIEW OF CONTRACTOR FURNISHED REDLINED PLANSINDICATING CHANGES INCORPORATED DURING CONSTRUCTION,AND WITNESSED UTILITY TESTING OF DRINKING WATER ANDWASTEWATER SYSTEMS. ALTHOUGH THE ACCURACY CAN NOTBE GUARANTEED, THE ENGINEER BELIEVES THIS RECORDDRAWING IS CORRECT TO THE BEST OF HIS/HER KNOWLEDGE.FL LIC. # ATDATE: Oct. 29, 2018FRANK A. PORTER, P.E.FL. LIC. #69092201 S. BUMBY AVE.ORLANDO, FL(407) 896-3317WWW.NV5.COMCERTIFICATE OF AUTHORIZATION # 29065SITE PLANC4.0 JPMRIDFAP13034.22WSTC LOT 4 COMMERCIALS.R. 434 & TUSKAWILLA ROADWINTER SPRINGS, FLORIDAOCEAN BLEU GROUPNORTH40200
SCALE: 1" = 20'
B
D
G
H
J
SITE LEGEND
ACCESSIBLE PARKING SPACE (TYP). SEE DETAIL FOR ACCESSIBLE PARKING SPACE, SIGN AND SYMBOL. (SEE DETAIL
1, SHEET C8.0).
PAVEMENT MARKINGS (TYP). PER FDOT INDEX 17346
FDOT INDEX 304 HANDICAP RAMP WITH DETECTABLE WARNING SURFACE (TYP). (SEE DETAIL 2, SHEET C8.0).
18" CURB AND GUTTER (SEE DETAIL 3, SHEET C7.0).
CONCRETE SIDEWALK. (SEE DETAIL 1, SHEET C7.0).
(2) DUMPSTER ENCLOSURES ( (1)-RECYCLING & (1) TRASH ) PER ARCH. PLANS
BIKE RACKS. (SEE DETAIL 4, SHEET C8.0).
PROPOSED MONUMENT SIGN. (SEE ARCH. PLANS)
DECORATIVE STOP SIGN (R1-1) - HIGH REFLECTIVE INTENSITY
PRIVATE PEDESTRIAN CROSSWALK WITH (1)-12" WHITE STRIPE PERPENDICULAR ON BOTH SIDES
(SEE DETAIL 7, SHEET C7.0). 6' WIDE UNLESS OTHER WISE NOTED ON PLANS.
TIE INTO EXISTING DECORATIVE KNEE WALL WITH 18LF OF DECORATIVE KNEEWALL (SEE ARCH. PLANS).
PROPOSED 12' WIDE CONCRETE SIDEWALK
DECORATIVE RAILING (PER ARCH. PLANS)
POTENTIAL TRANSFORMER LOCATION, FINAL LOCATION TO BE DETERMINED BY DUKE ENERGY.
6' CURB TRANSITION
CONCRETE WHEEL STOP
E
F
I
K
C
A
L
SITE INFORMATION:
SITE DATA:
LOT 4 0.83 AC 100.00%
OPEN SPACE PROVIDED: 0.104 AC (12.56%)
PARKING REQUIRED:
BASED ON GENERAL TENANT CRITERIA
PARKING PROVIDED:
STANDARD PARKING: (9' x 18') 49 SPACES
HC VAN ACCESSIBLE:(12' x 18') 2 SPACES
TOTAL: 51 SPACES
ON-STREET (OFFSITE):(9' x 20')6 SPACES
EXISTING USE: VACANT LAND
PROPOSED USE: COMMERCIAL
BUILDING MIN HEIGHT: 2 STORIES
BUILDING MAX HEIGHT: 5 STORIES
FAR: SF = 0.19
T-5 BUILDING SETBACKS
FRONT MIN. 0 FT
FRONT MAX. 8 FT
REAR 3 FT
SIDE MIN. 0 FT
SIDE MAX. 24 FT
LANDSCAPE BUFFER
ADJACENT TO R-O-W:0'
ADJACENT PROPERTY:0'
EXISTING ZONING/FUTURE LAND USE: TC
PROPOSED ZONING/FUTURE LAND USE: TC
NOTE: ALL SIGNS SHALL USE DECORATIVE BASE PER DETAIL 3, SHEET C8.0.
M
SINGLE WHITE SOLID LINE / 4" WIDE
SITE LEGEND
SWSL/4"
N
O
PAVEMENT LEGEND
REGULAR DUTY CONCRETE
HARD SCPAE PER ARCH. PLANS.
SINGLE WHITE SOLID LINE / 12" WIDESWSL/12"
SINGLE WHITE SOLID LINE / 24" WIDESWSL/24"
P
sheet numberproject numberREVISION SCHEDULEDATEDESCRIPTIONissue datedrawn byapproved by0A2.1DIMENSIONFLOOR PLANRMHRMHWMWW.BHM.US.COFLOOR PLAN1Scale: 3/16" = 1'-0"100'-0"FIN FLRNLEASE SPACE100773 SF.THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF BHM ARCHITECTURE, INC. AND ARE ISSUED ONLY FOR THE SPECIFIC PROJECT NOTED ON THESEDRAWINGS. ANY REPRODUCTION AND/OR REDISTRIBUTION WITHOUT THE EXPRESSED WRITTEN CONSENT OF BHM ARCHITECTURE, INC. IS PROHIBITED BY LAW. TO THEBEST OF THE ARCHITECT'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRESAFETY STANDARDS.1ABHM ARCHITECTURE, INC.MAIL ONLY: 478 E ALTAMONTE DR.,SUITE 108 PMB 264ALTAMONTE SPRINGS, FL 32701-4622PHONE: 407.333.2005 LICENSE # AAC000233RETAIL BUILDINGSR 434 & Michael Blake BlvdWinter Springs, Florida2018.00510-29-18AESTHETIC REVEWCamala McCarter HogueAR-0009533BC61'-4"
3'-4"
30'-0"30'-0"3'-4"13'-4"4'-0"3'-4"13'-4"4'-0"2'-9"3'-4"2'-0"3'-4"2'-0"3'-4"2'-9"3'-0"2'-9"3'-4"2'-0"3'-4"2'-0"3'-4"2'-9"4'-0"13'-4"3'-4"234100'-0"FIN FLRLEASE SPACE200781 SF.100'-0"FIN FLRLEASE SPACE4001,223 SF100'-0"FIN FLRLEASE SPACE5001,223 SF100'-0"FIN FLRLEASE SPACE6001,160 SF100'-0"FIN FLRLEASE SPACE7001,167 SF120'-0"40'-3"39'-6"40'-3"FIRE RISER8003'-0"3'-4"2'-0"121'-4"8"8"CONCRETE SLAB ONGRADE AT ROOM 800.SEE STRUCTURAL.8"60'-0"8"VERTICAL ELEVATION NOTE1.THE VERTICAL ELEVATIONS ARE BASED UPON THE FINISHFLOOR ELEVATION AT AN ASSUMED 100'-0". THE ACTUALFINISH FLOOR ELEVATION IS 41.65' AS NOTED ON THE CIVILENGINEERING DRAWINGS. FOR REFERENCE PURPOSES:100'-0" = 41.65'LEASE SPACE300773 SF.100'-0"FIN FLR6'-6"3'-4"3'-4"2'-0"3'-4"2'-0"3'-4"3'-4"6'-6"3'-0"2'-4"2'-4"3'-4"2'-0"3'-4"2'-0"3'-4"2'-6"2'-0"2'-2"9'-8"2'-2"2'-0"7'-10"2'-0"9'-8"2'-8"9'-8"2'-0"7'-10"2'-0"2'-2"9'-8"2'-2"2'-0"2'-6"3'-4"2'-0"3'-4"2'-0"3'-4"2'-4"2'-4"13'-4"4'-0"3'-0"3'-4"2'-0"3'-4"5'-4"3'-0"3'-0"2'-2"9'-8"2'-2"3'-0"10'-5"16'-11"10'-5"3'-4"2'-0"3'-4"3'-0"3'-0"2'-2"9'-8"2'-2"2'-4"12'-0"DIMENSION NOTES1. GENERALLY PLAN DIMENSIONS ARE FROM FACE OF CMU WALL TO CENTER OFSTUD WALLS EXCEPT AT CORRIDORS & CRITICAL CLEAR DIMENSIONS WHEREDIMENSION IS FROM FACE OF FINISHED GYPSUM BOARD ON SIDE WHERE CLEARDIMENSION MUST BE HELD.2. ALL INTERIOR FRAME WALLS ARE 6" METAL STUD U.N.O.3. WINDOW & DOOR OPENINGS ARE GENERALLY DIMENSIONED TO THE EDGE OFROUGH OPENINGS FOR EXTERIOR CMU WALLS & TO CENTERLINE OF INTERIOROPENINGS.4. TYPICALLY DOORS ARE LOCATED 4" OFF OF ADJACENT WALL EXCLUSIVE OFFRAME U.N.O. ALL OTHER DOOR OPENINGS ARE LOCATED TO ONE SIDE OFROUGH OPENING, FRAME EXCLUSIVE.5. DO NOT SCALE THIS DRAWING.5'-5"
sheet number
project number
REVISION SCHEDULE
DATE DESCRIPTION
issue date drawn by approved by
0
A6.1EXTERIOR ELEVATIONS
RMH RMH
W MWW.B H M .U S .C O
THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF BHM ARCHITECTURE, INC. AND ARE ISSUED ONLY FOR THE SPECIFIC PROJECT NOTED ON THESE
DRAWINGS. ANY REPRODUCTION AND/OR REDISTRIBUTION WITHOUT THE EXPRESSED WRITTEN CONSENT OF BHM ARCHITECTURE, INC. IS PROHIBITED BY LAW. TO THE
BEST OF THE ARCHITECT'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE
SAFETY STANDARDS.
BHM ARCHITECTURE, INC.
MAIL ONLY: 478 E ALTAMONTE DR.,
SUITE 108 PMB 264
ALTAMONTE SPRINGS, FL 32701-4622
PHONE: 407.333.2005 LICENSE # AAC000233
SOUTH ELEVATION3Scale: 3/16" = 1'-0"
NORTH ELEVATION4Scale: 3/16" = 1'-0"
EAST ELEVATION1Scale: 3/16" = 1'-0"
WEST ELEVATION2Scale: 3/16" = 1'-0"
100'-0"
FIN FLR
124'-4" +/-
PARAPET
102'-8"
BOTT SILL
110'-0"
T.O. ENTRY DOOR
124'-0"
TOP CMU
100'-0"
FIN FLR
127'-7" +/-
PARAPET
124'-4" +/-
PARAPET
07920 JOINT SEALANTS
07920.A1 JOINT SEALANT
09220 PORTLAND CEMENT PLASTERING09220.B1 2-COAT STUCCO DIRECT MASONRY BOND
09220.F8 ALUMINUM REVEAL TRIM
10532 METAL ENTRY CANOPIES
10532.A3 PRE-FABRICATED SUSPENDED METAL CANOPY
07620.A9
ALUMINUM
07460.D4
03001.Y8
03001.Y8
10532.A3
10532.A3
P3
07620.A9
ALUMINUM
P3
10532.A4
07620.A9
ALUMINUM
10532.A3
10532.A4 PRE-ENGINEERED METAL AWNING- STANDING SEAM
F
07620.P4
09220.B2
SAND FINISH
P1
S1
1
A6.2
100'-0"
FIN FLR
100'-0"
FIN FLR
07460.A1 P2
07460.D4 P3
09220.B1
SAND FINISH
P1
10532.A4
10532.A3
118'-1" +/-
PARAPET
09220.F8
07620.A9
ALUMINUM 09220.F8
09220.B1
SAND FINISH
P1
08411.A1
127'-7" +/-
PARAPET
04210.A5
04220.F1
07460.D408411.A5
'FALSE WINDOW'
B1
116-'4"
TOP -BAND
102'-8"
BOTT SILLS1
04210.A5
04220.F1
B1
04210.A5B1
04210.R4
04210.R4
04210.A5B1
03001.Y8
114'-0"
TOP BRICK SOLDIER
04220.F1
03001.Y8
08411.A5
'FALSE WINDOW'
07460.D4
04210.A5 B1
S104220.F1
03001.Y8
04210.A5 B1
04210.R4
P3
08411.A5
'FALSE WINDOW'
RETAIL BUILDING
SR 434 & Michael Blake Blvd
Winter Springs, Florida
2018.00510-29-18
AESTHETIC REVEW
Camala McCarter HogueAR-0009533
04220.F1
09220.B1
SAND FINISH
P1
07460.D4 P3
04210.R4
04210.A5B1 10532.A4
04210.A5 B1
04210.R4
127'-4"
TOP CMU
08411.A5
'FALSE WINDOW'
FIBER CEMENT FASCIAS & TRIM- P3
JAMES HARDIE KHAKI BROWN
FIBER CEMENT WALL SIDING SYSTEM- P2
PAINT: SW 7046 "ANONYMOUS"
BRICK VENEER- BR-1
CHEROKEE BRICK: VELOUR MED. GRAY
GLAZING-CLEAR INSULATED LOW "E".
STUCCO- SAND FINISH- P1
PAINT: SW 7045 "INTELLECTUAL GRAY"
EXTERIOR FINISH LEGEND
STOREFRONT FRAMES, DOWNSPOUTS,
SCUPPERS, LADDER & METAL AWNINGS.
PARAPET COPING: BRONZE ANODIZED
METAL CANOPIES
MATCH RAL#7021 MATTE / MT0028 "FLAT BLACK"
PREFINISHED / POWDERCOAT
SPLIT- FACED BLOCK- S1
PAINT: SW 7045 "INTELLECTUAL GRAY"
HOLLOW METAL DOORS & FRAMES
PAINT P-1 OR P-2 MATCH ADJACENT
NOTE: SW= SHERWIN WILLIAMS
P3
07460.A1 P3
10532.A4
S1
S1
07460.A1P2
07460.D4P3
P307460.C4
10532.A3
04220.F1S1
E FB
C
B B
C
B
F B B A
F F F
F
F F F F
FFF
F F F F F
300B
1
A6.2
1
A6.5
4
A6.2
1
A6.3 3
A6.2
2
A6.3 SIM
3
A6.3 SIM
2
A6.2
2
A6.2
3
A6.2
07460.D4P3
P3 07460.C4
10532.A3
08411.A2
03001.Y8
10532.A4
P3 07460.C4
04210.R2
04210.R2
P307460.C4
S104220.F1 10532.A4
09220.F8
08411.A1 08411.A1
BLACK-OUT FILM
08411.A2
BLACK-OUT FILM
08411.A1
BLACK-OUT FILM
04210.R2
P3 07460.C4
04210.A5 B1
04210.A5 B1
04210.R4
04210.A5B1
09220.F8
09220.B1
SAND FINISH
P1
08411.A2
BLACK-OUT FILM
08411.A1
BLACK-OUT FILM
04210.A5 B104210.R4
09220.B1
SAND FINISH
P1
SELECTIVE KEYNOTES
03001 CONCRETE WORK
03001.Y8 PRECAST CONCRETE SILL
04210 CLAY UNIT MASONRY
04210.R4 BRICK SOLDIER COURSE
04210.A5 BRICK VENEER
04220 CONCRETE UNIT MASONRY
04220.F1 SPLIT-FACE CMU BLOCK
04210.R2 BRICK ROWLOCK COURSE 07620 SHEET METAL FLASHING AND TRIM
07620.A9 METAL COPING
07620.P4 OVERFLOW SCUPPER
07460 SIDING
07460.A1 FIBER-CEMENT WALL SIDING SYSTEM
07460.D4 FIBER-CEMENT FASCIA BOARD - SMOOTH
07460.C4 FIBER-CEMENT TRIM BOARD - SMOOTH
4
A6.2
5
A6.2
F F F F F F
B
C
D700C 700B 100A 200A 300AD
C
B
400B B
C
B800A E500B 600B
B
C
B700A D 600A D 500A D 400A D 100B B BB
4
A6.2
2
A6.4
4
A6.3
08411.A5
'FALSE WINDOW'
5
A6.3
5
A6.3
3
A6.3 SIM
2
A6.3
3
A6.3
3
A6.4
3
A6.4
4
A6.4 2
A6.5
13
A8.2
13
A8.2
08411 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS08411.A1 ALUMINUM-FRAMED STOREFRONT
08411.A2 ALUMINUM/GLASS ENTRANCE DOOR
08411.A5 ALUMINUM STOREFRONT- NARROW PROFILE
09220.B2
SAND FINISH
P1
13
A8.2
13
A8.2 12
A8.2
11
A8.2
11
A8.2
3
A6.5
A6.1MEXTERIOR ELEVATIONS
sheet number
project numberissue date drawn by approved by
THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF BHM ARCHITECTURE, INC. AND ARE ISSUED ONLY FOR THE SPECIFIC PROJECT NOTED ON THESE
DRAWINGS. ANY REPRODUCTION AND/OR REDISTRIBUTION WITHOUT THE EXPRESSED WRITTEN CONSENT OF BHM ARCHITECTURE, INC. IS PROHIBITED BY LAW. TO THE
BEST OF THE ARCHITECT'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE
SAFETY STANDARDS.
BHM ARCHITECTURE, INC.
MAIL ONLY: 478 E ALTAMONTE DR.,
SUITE 108 PMB 264
ALTAMONTE SPRINGS, FL 32701-4622
PHONE: 407.333.2005 LICENSE # AAC000233
REVISION SCHEDULE
DATE DESCRIPTION
RMH RMH
SOUTH ELEVATION3
NORTH ELEVATION4
EAST ELEVATION1 WEST ELEVATION2
0
100'-0"
FIN FLR
124'-4" +/-PARAPET
102'-8"
BOTT SILL
110'-0"
T.O. ENTRY DOOR
100'-0"
FIN FLR
127'-7" +/-PARAPET
124'-4" +/-PARAPET
100'-0"
FIN FLR
100'-0"
FIN FLR
119'-0" +/-
PARAPET
127'-7" +/-PARAPET
116'-4"
TOP -BAND
102'-8"
BOTT SILL
114'-0"TOP BRICK SOLDIER
127'-7" +/-PARAPET
124'-4" +/-
PARAPET
W MWW.B H M .U S .C O
SELECTIVE KEYNOTES
Scale:3/16" = 1'-0"
Scale:3/16" = 1'-0"
Scale:3/16" = 1'-0"Scale:3/16" = 1'-0"
07620.A9
ALUMINUM
07460.D4
03001.Y8
03001.Y8
10532.A3
07460.A1
10532.A3
08411.A2
07620.A9
ALUMINUM
10532.A4
07620.A9
ALUMINUM
10532.A3
08411.A1
07620.P4
09220.B2
SAND FINISH
07460.D4
09220.B1
SAND FINISH
10532.A4
10532.A3
09220.F8
05515.A1
07620.A9
ALUMINUM
09220.F8
09220.B2
SAND FINISH
08411.A1 04210.A5 04220.F1
07460.D4
08411.A5
'FALSE WINDOW'
04210.A5
04220.F1
04210.A5
04210.R4
04210.R4
04210.A5
03001.Y8
04220.F1
03001.Y8
08411.A5
'FALSE WINDOW'
09220.B1
SAND FINISH
07460.D4
04210.A5
04220.F1
03001.Y8
04210.A5
04210.R4
08411.A5
'FALSE WINDOW'
04220.F1
09220.B1
SAND FINISH
07460.D4
04210.R4
10532.A4
04210.A5
04210.R4
08411.A5
'FALSE WINDOW'
10532.A4
07460.A107460.D4
07460.C4
10532.A3
04220.F1
07460.C4
07460.A1
08411.A2 04220.F1
03001.Y8
07460.A1
04210.A5
09220.F8
07460.C4
04210.A5
09220.B1
SAND FINISH
08411.A208411.A1
04210.A5
07460.A1
10532.A3
07460.C4 07460.C4
08411.A1
BLACK-OUT GLASS
RETAIL BUILDING
SR 434 & Michael Blake Blvd
Winter Springs, Florida
2018.00510-29-18
AESTHETIC REVEW
Camala McCarter Hogue
AR-0009533
FIBER CEMENT FASCIAS & TRIM- P3
JAMES HARDIE KHAKI BROWN
FIBER CEMENT WALL SIDING SYSTEM- P2
PAINT: SW 7046 "ANONYMOUS"
BRICK VENEER- BR-1
CHEROKEE BRICK: VELOUR MED. GRAY
GLAZING-CLEAR INSULATED LOW "E".
STUCCO- SAND FINISH- P1
PAINT: SW 7045 "INTELLECTUAL GRAY"
STOREFRONT FRAMES, DOWNSPOUTS,
SCUPPERS, LADDER & METAL AWNINGS.
PARAPET COPING: BRONZE ANODIZED
METAL CANOPIES
MATCH RAL#7021 MATTE / MT0028 "FLAT BLACK"
PREFINISHED / POWDERCOAT
SPLIT- FACED BLOCK- S1
PAINT: SW 7045 "INTELLECTUAL GRAY"
HOLLOW METAL DOORS & FRAMES
PAINT P-1 OR P-2 MATCH ADJACENT
NOTE: SW= SHERWIN WILLIAMS
EXTERIOR FINISH LEGEND
05515 PRE-MAUNFACTURED ALUMINUM ACCESS LADDER 07620 SHEET METAL FLASHING AND TRIM
08411 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
09220 PORTLAND CEMENT PLASTERING
10532 METAL ENTRY CANOPIES07460SIDING
03001 CONCRETE WORK
04210 CLAY UNIT MASONRY
04220 CONCRETE UNIT MASONRY
05515.A1 PRE-MANUFACTURED ALUMINUM LADDER ASSEMBLY05500.A7 ALUMINUM PANEL SECURITY DOOR
07620.A9 METAL COPING
07620.P4 OVERFLOW SCUPPER
08411.A1 ALUMINUM-FRAMED STOREFRONT08411.A2 ALUMINUM/GLASS ENTRANCE DOOR
09220.B1 2-COAT STUCCO DIRECT MASONRY BOND
09220.F8 ALUMINUM REVEAL TRIM
10532.A3 PRE-FABRICATED SUSPENDED METAL CANOPY
10532.A4 PRE-ENGINEERED METAL AWNING- STANDING SEAM
03001.Y8 PRECAST CONCRETE SILL
04210.R4 BRICK SOLDIER COURSE04210.A5 BRICK VENEER 07460.A1 FIBER-CEMENT WALL SIDING SYSTEM
07460.D4 FIBER-CEMENT FASCIA BOARD - SMOOTH07460.C4 FIBER-CEMENT TRIM BOARD - SMOOTH
04220.F1 SPLIT-FACE CMU BLOCK
08411.A5 ALUMINUM STOREFRONT- NARROW PROFILE
A6.6MDUMPSTER ENCLOSURE
& WALL SECTION sheet number
project numberissue date drawn by approved by
THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF BHM ARCHITECTURE, INC. AND ARE ISSUED ONLY FOR THE SPECIFIC PROJECT NOTED ON THESE
DRAWINGS. ANY REPRODUCTION AND/OR REDISTRIBUTION WITHOUT THE EXPRESSED WRITTEN CONSENT OF BHM ARCHITECTURE, INC. IS PROHIBITED BY LAW. TO THE
BEST OF THE ARCHITECT'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE
SAFETY STANDARDS.
BHM ARCHITECTURE, INC.
MAIL ONLY: 478 E ALTAMONTE DR.,
SUITE 108 PMB 264
ALTAMONTE SPRINGS, FL 32701-4622
PHONE: 407.333.2005 LICENSE # AAC000233
REVISION SCHEDULE
DATE DESCRIPTION
RMH RMH
DUMPSTER ENCLOSURE ELEVATIONS2
DUMPSTER ENCLOSURE SECTION3
DUMPSTER ENCLOSURE PLAN1
0
3
A6.5
2C
A6.5
2D
A6.5
2B
A6.5
2A
A6.5
3
A6.5
3
A6.5
W MWW.B H M .U S .C O
SELECTIVE KEYNOTES
Scale:1/4" = 1'-0"
Scale:1/2" = 1'-0"
Scale:1/4" = 1'-0"
03001.A6
SEE STRUCTURAL
05001.B3
6 X 6
09220.B1
SAND FINISH
04220.F1
05001.B3
6 X 6
04220.F1
09220.B1
5/8"
04220.B3
SEE STRUCTURAL
04220.P5
SEE STRUCTURAL
05001.B3
6 X 6
05001.B3
6 X 6
04220.D1
8"
04220.D1
8"
04220.D1
8"
03001.C4
6" - SEE STRUCT
03001.C4
6" - SEE STRUCT
05001.B3
6 X 6
09220.K2
03001.Y8
09220.B1
SAND FINISH
04730.A1
05001.B3
6 X 609220.K2
04730.A3
05001.B3
6 X 6
09220.B1
SAND FINISH
04220.F1
09220.K2
03001.Y8
03001.Y8
09220.K2
1"
04220.D1
04220.P5
SEE STRUCTURAL
13'-4"
3'-8"3'-0"3'-0"3'-8"12'-8"10'-8"6"5"10'-0"6"11'-6"12'-2"6"7'-4"2'-10"2'-10"7'-4"4'-0"6"
26'-0"
3'-0"3'-0"3'-0"3'-8"
4"12'-0"4"
1"10'-8"6"5"4"12'-8"4"12'-4"23'-0"6"7'-4"2'-10"9"04220 CONCRETE UNIT MASONRY
09220 PORTLAND CEMENT PLASTERING
03001 CONCRETE WORK
CL CL CL
CLCLCL CL CL
CL
CL
CLCLCL CL
05001 STRUCTURAL STEEL WORK
04220.D1 CMU BLOCK
04220.B3 MASONRY BOND BEAM
09220.B1 2-COAT STUCCO DIRECT MASONRY BOND
03001.A6 CONCRETE FOOTING
03001.C4 CONCRETE SLAB ON GRADE
04220.P5 CONCRETE FILLED CELLS W/ VERTICAL REINFORCING
09220.K2 STUCCO TRIM BAND
03001.E6 CONCRETE SIDEWALK
03001.Y8 PRECAST CONCRETE SILL
04220.F1 SPLIT-FACE CMU BLOCK
05001.B3 STEEL TUBE COLUMN
RETAIL BUILDING
SR 434 & Michael Blake Blvd
Winter Springs, Florida
2018.00510-29-18
AESTHETIC REVEW
Camala McCarter Hogue
AR-0009533
March 2005
BOARD OF ADJUSTMENT APPLICATION
CONDITIONAL USE / SPECIAL EXCEPTION
VARIANCE
WAIVER
APPLICANT:
Last First Middle
MAILING ADDRESS:
City State Zip Code
PHONE & EMAIL
If Applicant does NOT own the property:
PROPERTY OWNER:
Last First Middle
MAILING ADDRESS:
City State Zip Code
PHONE & EMAIL
This request is for the real property described below:
PROPERTY ADDRESS:
TAX PARCEL NUMBER:
SIZE OF PARCEL:
Square Feet Acres
EXISTING LAND USE:
Current FUTURE LAND USE Classification:
Current ZONING Classification:
Please state YOUR REQUEST:
CITY OF WINTER SPRINGS
COMMUNITY DEVELOPMENT DEPARTMENT
1126 STATE ROAD 434
WINTER SPRINGS, FL 32708
407-327-5966
FAX:407-327-6695
March 2005
2
The APPLICANT IS RESPONSIBLE for posting the blue notice card (provided by the City) on the site at
least SEVEN (7) DAYS prior to the Board of Adjustment Meeting at which the matter will be considered.
Said notice shall NOT be posted within the City right-of-way. All APPLICANTS shall be afforded minimal
due process as required by law, including the right to receive notice, be heard, present evidence, cross-
examine witnesses, and be represented by a duly authorized representative.
The CITY COMMISSION shall render all final decisions regarding variances, conditional uses and waivers
and may impose reasonable conditions on any approved variance, conditional use or waiver to the extent
deemed necessary and relevant to ensure compliance with applicable criteria and other applicable
provisions of the City Code and Comprehensive Plan. All formal decisions shall be based on competent
substantial evidence and the applicable criteria as set forth in Chapter 20, Zoning. APPLICANTS are
advised that if, they decide to appeal any decisions made at the meetings or hearings with respect to any
matter considered at the meetings or hearings, they will need a record of the proceedings and, for such
purposes, they will need to insure that a verbatim record of the proceedings is made, at their cost, which
includes the testimony and evidence upon which the appeal is to be based, per 286.0105, Florida Statutes.
Any CONDITIONAL USE, VARIANCE, or WAIVER which may be granted by the City Commission shall
expire two (2) years after the effective date of such approval by the City Commission, unless a building
permit based upon and incorporating the conditional use, variance, or waiver is issued by the City within
said time period. Upon written request of the property owner, the City Commission may extend the
expiration date, without public hearing, an additional six (6) months, provided the property owner
demonstrates good cause for the extension In addition, if the aforementioned building permit is timely
issued, and the building permit subsequently expires and the subject development project is abandoned or
discontinued for a period of six months, the conditional use, variance or waiver shall be deemed expired
and null and void. (Code of Ordinances, Section 20-36.)
THE FOLLOWING ITEMS ARE TO BE SUPPLIED WITH THIS APPLICATION:
A copy of the most recent SURVEY of the subject property.
A copy of the LEGAL DESCRIPTION reflecting the property boundaries.
11 x 17 MAP showing ADJACENT STREETS and ZONING AND LAND USE classifications
on the ADJACENT PROPERTY.
JUSTIFICATION for the Request (See Attached List)
NAMES and ADDRESSES of each property owner within 150 ft. of each property line.
Notarized AUTHORIZATION of the Owner,
IF the Applicant is other than the Owner or Attorney for the Owner (see below).
APPLICATION FEES:
FEES are as SHOWN BELOW plus ACTUAL COSTS incurred for ADVERTISING or NOTIFICATION,
and for REIMBURSEMENT for TECHNICAL and/or PROFESSIONAL SERVICES which may be
required in connection with the review, inspection or approval of any development (based on accounting
submitted by the City’s Consultant) , payable prior to approval of the pertinent stage of development.
CONDITIONAL USE / SPECIAL EXCEPTION $ 500
WAIVER $ 500
VARIANCE $ 500
TOTAL DUE $
March 2005
3
By submitting this application you hereby grant temporary right of entry for city officials to enter upon the subject
property for purposes of evaluating this application.
**************************************************************************************
FOR USE WHEN APPLICANT IS OWNER OF THE SUBJECT REAL PROPERTY:
This is to certify that I am the Owner in fee simple of subject lands described within this Application for
Board of Adjustment consideration:
Signature of Owner
Sworn to and subscribed before me this
day of 20 . Notary Public
My Commission expires:
Personally Known
Produced Identification:
(Type)
Did take an Oath
Did Not take and Oath
**************************************************************************************
FOR USE WHEN APPLICANT IS NOT OWNER OF THE SUBJECT REAL PROPERTY:
I, do hereby, with my notarized signature, allow
to represent me in this Application related to my property. The
property is identified as: Tax Parcel Number(s)
Located at _____________________________________________________________________________
Signature of Owner(s)
Sworn to and subscribed before me this
day of 20 . Notary Public
My Commission expires:
Personally Known
Produced ID: (Type)
Did take an Oath
Did Not take and Oath
**************************************************************************************
20-321(c) Town Center Special Exceptions
(1) The city commission may by special exception waive strict compliance with provisions of this
code in furtherance of promoting the town center policies adopted by the city. In granting a
special exception, the city commission must find by substantial competent evidence that:
a. The proposed development contributes to, promotes and encourages the improvement
of the Winter Springs Town Center and catalyzes other development as envisioned in the
Winter Springs Town Center regulations.
b. The proposed development will not have an unfavorable effect on the economy of the
Winter Springs Town Center and complies with the economic fiscal impact requirements
set forth in the City's Comprehensive Plan and Code.
c. The proposed development abides by all rules in this code other than those specially
excepted. Special limitations apply to large footprint buildings (greater than twenty
thousand (20,000) square feet); see subsection 20-324(9) for these limitations.
d. The proposed development meets any reasonable additional conditions, restrictions or
limitations deemed necessary by the city commission in order to preserve and promote
the intent of the Winter Springs Town Center District Code.
e. With respect to each waiver requested, the specific waiver shall comply with all of the
following:
1. Is a result of special conditions and circumstances which are peculiar to the land, site
plan, structure or building involved and which justify granting the waiver in the
context of the overall proposed development being successful within the town center;
2. Is the minimum waiver from the town center regulations necessary to make possible
the reasonable use of the land, building or structure;
3. Is in harmony with the general intent and purpose of the town center regulations;
4. Will not be injurious or incompatible to the town center and any surrounding
neighborhood or property; and
5. Will not create a public nuisance or be detrimental to the public health, safety, and
welfare relative to public services including water, sewer, surface water management,
police, fire, parks and recreation, streets and traffic patterns, public transportation,
marina and water ways, bicycle and pedestrian facilities.
Special Exceptions Requested:
1. Requesting a waiver for a 13.56’ building setback, which is greater than the 8’ maximum setback
required in Sec. 20-325 (T5 Transect).
2. Requesting a waiver for a lot dimensions of 222’ x 174’ which is larger than the 180’ x 160’ required in
Sec. 20-325 (T5 Transect).
3. Requesting a waiver for 54% frontage buildout which is less than the 80% coverage required in Sec. 20-
325 (T5 Transect).
4. A parking setback of 24’ from the property line along the main street, which is less than the 50’
minimum required in Sec. 20-325.
5. Requesting a waiver for the requirement of a 6’ landscape island separating more than 6 consecutive
parking spaces.
20-321(c} Town Center Special Exceptions
(1) The city commission may by special exception waive strict compliance with provisions of this code in
furtherance of promoting the town center policies adopted by the city. In granting a special exception, the city
commission must find by substantial competent evidence that:
(a) The proposed to development contributes, promotes and encourages the improvement of the
Winter Springs Town Center and catalyzes other development as envisioned in the Winter Springs Town
Center regulations.
The proposed development will add 7 retail units to the prominent corner of SR434 and Michael Blake
Boulevard which is consistent with the mixed use nature of the overall Town Center.
(b)The proposed development will not have an unfavorable effect on the economy of the Winter Springs
Town Center and complies with the economic fiscal impact requirements set forth in the City's
Comprehensive Plan and Code.
The development of retail units in the proposed development will have a positive impact on the
economy of the Winter Springs Town Center by locating shopping areas directly adjacent to local
consumers in the Town Center who will be shopping and dining locally and generating more demand
for local business.
(c) The proposed development abides by all rules in this code other than those specially excepted.
Special limitations apply to large footprint buildings (greater than twenty thousand (20,000) square
feet); see subsection 20-324(9) for these limitations.
The proposed development will abide by all rules in the code other than those being requested in this
Special Exception application. The proposed development does not proposed any building with
footprints larger than 20,000 square feet.
(d) The proposed development meets any reasonable additional conditions, restrictions or limitations
deemed necessary by the city commission in order to preserve and promote the intent of the Winter
Springs Town Center District Code.
If the City Commission proposes any reasonable additional conditions, restrictions, or limitations, the
Developer will strive to meet them.
(e) With respect to each waiver requested, the specific waiver shall comply with all of the following:
Special Exception 1:
1. Is a result of special conditions and circumstances which are peculiar to the land, site plan, structure
or building involved and which justify granting the waiver in the context of the overall proposed
development being successful within the town center;
This special exception is due to the adjacent Starbucks development and allows space for the creation
of a storefront type aesthetic along SR 434. The building front is placed 22’ closer to SR 434 than the
Starbucks.
2. Is the minimum waiver from the town center regulations necessary to make possible the reasonable
use of the land, building or structure;
This special exception is the minimum necessary to have a congruent lot configuration with the
adjacent Starbucks.
3. Is in harmony with the general intent and purpose of the town center regulations;
This special exception is in harmony with the general intent of the town center in that it allows for the
development of additional retail along the SR 434 corridor.
4. Will not be injurious or incompatible to the town center and any surrounding neighborhood or
property; and
This special exception will not be incompatible to the town center since it makes good use of the
remaining property with good internal block circulation.
5. Will not create a public nuisance or be detrimental to the public health, safety, and welfare relative to
public services including water, sewer, surface water management, police, fire, parks and recreation,
streets and traffic patterns, public transportation, marina and water ways, bicycle and pedestrian
facilities.
This special exception will not create public nuisance or be detrimental to public health, safety, and
welfare relative to public services since the area in question will be on private property.
Special Exception 2:
1. Is a result of special conditions and circumstances which are peculiar to the land, site plan, structure
or building involved and which justify granting the waiver in the context of the overall proposed
development being successful within the town center;
This special exception is due to the peculiar shape of the remaining lot of land after the Starbucks was
developed.
2. Is the minimum waiver from the town center regulations necessary to make possible the reasonable
use of the land, building or structure;
This special exception is necessary since subdividing this remaining lot would create at least one that
would be very difficult to develop with a retail user.
3. Is in harmony with the general intent and purpose of the town center regulations;
This special exception is in harmony with the general intent of the town center in that it allows for the
development of additional retail along the SR 434 corridor.
4. Will not be injurious or incompatible to the town center and any surrounding neighborhood or
property; and
This special exception will not be incompatible to the town center since it makes good use of the
remaining property with good internal block circulation.
5. Will not create a public nuisance or be detrimental to the public health, safety, and welfare relative to
public services including water, sewer, surface water management, police, fire, parks and recreation,
streets and traffic patterns, public transportation, marina and water ways, bicycle and pedestrian
facilities.
This special exception will not create public nuisance or be detrimental to public health, safety, and
welfare relative to public services since the area in question will be on private property.
Special Exception 3:
1. Is a result of special conditions and circumstances which are peculiar to the land, site plan, structure
or building involved and which justify granting the waiver in the context of the overall proposed
development being successful within the town center;
This special exception is due to the configuration of the lot having a wide dimension and little depth.
Adding more retail along the frontage to achieve 80% coverage would not leave enough space behind
the building for off-street parking or allow for good internal circulation with the adjacent Starbucks
lot.
2. Is the minimum waiver from the town center regulations necessary to make possible the reasonable
use of the land, building or structure;
This special exception is the minimum necessary to allow the retail building to be placed along SR 434.
3. Is in harmony with the general intent and purpose of the town center regulations;
To keep in harmony with the general intent, the Developer will continue the small knee wall that
covers the Starbucks parking field across the parking field of this lot. This will help with the coverage
along the frontage.
4. Will not be injurious or incompatible to the town center and any surrounding neighborhood or
property; and
This special exception will not be incompatible to the town center since it is basically a continuation of
the Starbucks lot.
5. Will not create a public nuisance or be detrimental to the public health, safety, and welfare relative to
public services including water, sewer, surface water management, police, fire, parks and recreation,
streets and traffic patterns, public transportation, marina and water ways, bicycle and pedestrian
facilities.
This special exception will not create public nuisance or be detrimental to public health, safety, and
welfare relative to public services since the area in question will be on private property.
Special Exception 4:
1. Is a result of special conditions and circumstances which are peculiar to the land, site plan, structure
or building involved and which justify granting the waiver in the context of the overall proposed
development being successful within the town center;
This special exception is due to the configuration of the lot having a wide dimension and little depth.
The off-street parking is needed to meet minimum standards and since the lot is not that deep, the
parking field needs to encroach into the 50’ setback. This also allows for connection to the internal
circulation of the Starbucks lot.
2. Is the minimum waiver from the town center regulations necessary to make possible the reasonable
use of the land, building or structure;
This special exception is necessary to allow for the construction of the internal circulation connections
to Starbucks and parking required for the retail buildings.
3. Is in harmony with the general intent and purpose of the town center regulations;
This special exception is in harmony with the general intent of the town center in that the parking
area will be screened with a knee wall that will be continued from the Starbucks lot. This will help to
shield the parking area from SR 434.
4. Will not be injurious or incompatible to the town center and any surrounding neighborhood or
property; and
This special exception will allows for compatibility with the Starbucks lot.
5. Will not create a public nuisance or be detrimental to the public health, safety, and welfare relative to
public services including water, sewer, surface water management, police, fire, parks and recreation,
streets and traffic patterns, public transportation, marina and water ways, bicycle and pedestrian
facilities.
This special exception will not create public nuisance or be detrimental to public health, safety, and
welfare relative to public services since the area in question will be on private property.
Special Exception 5:
1. Is a result of special conditions and circumstances which are peculiar to the land, site plan, structure
or building involved and which justify granting the waiver in the context of the overall proposed
development being successful within the town center;
This special exception is needed to match the parking configuration of the adjacent Starbucks lot.
2. Is the minimum waiver from the town center regulations necessary to make possible the reasonable
use of the land, building or structure;
This special exception is necessary to allow for the construction of the internal circulation connections
to Starbucks and parking required for the retail buildings.
3. Is in harmony with the general intent and purpose of the town center regulations;
This special exception is in harmony with the general intent of the town center in that the parking
area will be screened with end cap islands and a knee wall on SR 434.
4. Will not be injurious or incompatible to the town center and any surrounding neighborhood or
property; and
This special exception will allow for compatibility with the Starbucks lot.
5. Will not create a public nuisance or be detrimental to the public health, safety, and welfare relative to
public services including water, sewer, surface water management, police, fire, parks and recreation,
streets and traffic patterns, public transportation, marina and water ways, bicycle and pedestrian
facilities.
This special exception will not create public nuisance or be detrimental to public health, safety, and
welfare relative to public services since the area in question will be on private property.
TITLE
West End Professional Center Monument Sign Special Exception
SUMMARY
APPLICANT AND PROPERTY INFORMATION:
• Applicant/Property owner’s name(s): West End Professional Center One LLP
• Property addresses: 1135 E. SR 434
•Property Parcel ID numbers:36-20-30-502-0000-0010
•Current FLUM Designation:Town Center District
•Current Zoning Designations:T-C (Town Center District)
•Development Agreements:None
•Pending Code Enforcement Actions:None
•City Liens (if any):None
PUBLIC HEARINGS AGENDA ITEM 4 0 1
PLANNING AND ZONING BOARD/LOCAL PLANNING AGENCY
MAY 23, 2019 | REGULAR MEETING
APPLICABLE LAW, PUBLIC POLICY, AND EVENTS:
Home Rule Powers
Winter Springs Code of Ordinances
City of Winter Springs Comprehensive Plan
Project Overview:
The applicant is seeking a Special Exception for the construction of one
monument sign at the multi-tenant office building located at 1135 E. R 434. The subject property is located within Transect 5 of the Town Center zoning district.
Per Section 20-327.1 - Signs, free standing monument signs are permitted by
special exception in the Town Center along SR 434 frontage. The sign generally
conforms to the standards set forth in Section 16-82 "Special Supplemental regulations for properties located on SR 434." The signs architectural features and
colors match the existing building and provide acceptable aesthetics in relation
to the surrounding Town Center buildings.”
P U B LI C HEA RI NG S AGENDA I TEM 401 | T H U RS D A Y , MA Y 2 3 , 2019 | PA G E 2 O F 2
Special Exceptions:
The applicant is requesting approval of a Special Exception requests. In granting a Special Exception, per the Town Center Code, the City Commission must find
substantial competent evidence that:
a.The proposed development contributes to, promotes, and encourages the
improvement of the Winter Springs Town Center and catalyzes otherdevelopment as envisioned in the Winter Springs Town Center regulations.
b.The proposed development will not have an unfavorable effect on the
economy of the Winter Springs Town Center and complies with the
economic fiscal impact requirements set forth in the City’s Comprehensive
Plan and code.
c.The proposed development abides by all rules in this code other than those
specially accepted.
RECOMMENDATION
Staff recommends approval of the Special Exception for the construction of a
monument sign in the Town Center..