HomeMy WebLinkAbout2016 08 08 Consent 302 Lift Station Panel ReplacementCOMMISSION AGENDA
ITEM 302
Informational
Consent
X
Public Hearings
Regular
August 08, 2016 KS KL
Regular Meeting City Manager Department
REQUEST:
The Utility Department requesting authorization to purchase two wastewater lift station
control panels from Stacon Inc. in the amount of $51,856.00 plus a 10% contingency.
SYNOPSIS:
This project consists of replacing the control panels for lift stations 1W and 5E. A lift
station has two pumps that convey wastewater collected via a gravity sewer system to the
wastewater treatment facility and a control panel contains all the electronics to operate the
lift station.
CONSIDERATIONS:
This project is needed to replace the control panels for two of the City's larger wastewater
lift stations; 1W on Cory Lane and 5E which is adjacent to Winter Springs Boulevard
across from Tuscawilla Greens. Both stations have two 20 HP pumps and the control
panels have deteriorated to the point that their reliability may be compromised. Both panels
are approximately 20 years old.
The City owns and operates 44 lift stations throughout the City. These two lift stations
whose control panels we have targeted for replacement are considered critical to the
wastewater operation due to the large areas they serve. Lift stations operate in a highly
corrosive environment which deteriorates the components within the station.
Consent 302 PAGE 1 OF 3 - August 08, 2016
The panels include; stainless steel enclosure, variable frequency drives, programmable logic
controller, alarms, generator receptacle, and surge protection. Two other quotes were
received; Rocha Controls - $83,278 and Xylem - $60,720.
No disruption of wastewater service is anticipated during this project which should be
completed in one day after the panels are received.
FISCAL IMPACT:
The project cost is $51,856.00 plus a 10% contingency funded by the Utility Enterprise
Fund Capital Improvements line code.
COMMUNICATION EFFORTS:
This Agenda Item has been electronically forwarded to the Mayor and City Commission,
City Manager, City Attorney /Staff, and is available on the City's Website, LaserFiche, and
the City's Server. Additionally, portions of this Agenda Item are typed verbatim on the
respective Meeting Agenda which has also been electronically forwarded to the individuals
noted above, and which is also available on the City's Website, LaserFiche, and the City's
Server; has been sent to applicable City Staff, Media/Press Representatives who have
requested Agendas /Agenda Item information, Homeowner's Associations/Representatives
on file with the City, and all individuals who have requested such information. This
information has also been posted outside City Hall, posted inside City Hall with additional
copies available for the General Public, and posted at six (6) different locations around the
City. Furthermore, this information is also available to any individual requestors. City Staff
is always willing to discuss this Agenda Item or any Agenda Item with any interested
individuals.
Consent 302 PAGE 2 OF 3 - August 08, 2016
RECOMMENDATION:
Staff recommends the City Commission authorize the purchase of two wastewater lift
station control panels from Stacon Inc. in the amount of $51,856.00 plus a 10%
contingency payable from the Utility Enterprise Fund Capital Improvements line code and
authorize the City Manager and City Attorney to prepare and execute any and all applicable
documents.
ATTACHMENTS:
1. StaCon Quote per panel (1 page)
Consent 302 PAGE 3 OF 3 - August 08, 2016
TO: City of Winter Springs ATTN: Geoff Marbes QUOTE NO.: 120955AD PUMP MODEL:
HP: 20 VOLTAGE'. 230 PHASE: 3 WIRE: 3 NO PUMPS/MOTORS: 2 PUMP FLA: N. E. C: 54
JOB NAME: City of Winter Springs -Lift Station 1 West
ENCLOSURE APPROX.
®3RX I. 62X48
BOX I
BOX N BOX X18
CUSTOM ENCLOSURE
MCC
MATERIAL
0304SS
ENCLOSURE BRAND - -- HOFFMAN
MODIFICATIONS
X AIR VENTS
ALARM CAGE
X DEAD FRONT
DOORSTOP
DRAINS
X DRIP SHIELD
INSULATION
X THREE POINT LATCH
LEGS
PARTITION
SKIRTS
SPECIAL POWDER COAT COLOR
ST STEEL LEGEND SCREWS
SUN SHIELD
TEMPERATURE SENSOR
WINDOW
AIR CONDITIONER
X INTRUSION SWITCH
MOTOR STARTERS
AMBIENT OVERLOADS
AUX CONTACTS
NEMA MOTOR STARTER
SOLID STATE MOTOR STARTERS
SOLID STATE OVERLOADS
PHASE CONVERTORS
VFD ATV312
X VFD- LINE FUSES
X VFD- LINE REACTORS
CONTACTOR
BREAKERS
AUX CONTACTS
X CONTROL Q -FRAME
X EMERGENCY
0 EXTRA SINGLE POLE
FUSIBLE DISCONNECT
X GEN RECEPTACLE JRS2044FR
HANDLE
X BREAKERINTERLOCK
LIGHTING PANEL
X MAIN
X SURGE ARRESTOR BREAKER*****
MOTOR
BREAKER PADLOCK ATTACHMENTS
X POWER TERMINALS
TVSS
X RECEPTACLE Q -FRAME
TRANSFORMER
CONTROL SYSTEM
APP CONTROLLER
TOUCH SCREEN
MPE BS2000 BUBBLER
APG CONTROLLER
MULTITRODE (BY OTHERS)
MPE CONTROLLER
X 3 FLOAT SYSTEM NO FLOATS INCLUDED
X PLC SCHNEIDER ELECTRIC -M340
MPE PROBE RELAY
PROBE
MILTRONICS CONTROLLER
MPE INTRINSIC SAFE DUPLEXOR
START /STOP PB-S
I�
PRESSURE TRANSDUCER
ULTRASONIC TRANSDUCER
X 1PLC PROGRAMMING BY STACON
ALARM HORN
ALARM LIGHT
ALARM SILENCE
ALARM TEST
ALTERNATOR BY M340 PLC
AMMETER W /CT'S
ABL 8 (SCHNEIDER ELECTRIC POWER SUPPLY)
AWG #14 WIRING
BEARING PL
BREAKER TRIP PL
COPPER GROUND BUS
COUNTERS
DC ALARM /BAT BACK UP
DIALER
DIM GLOW LIGHTS
ELAPSED TIME METERS
ETM SIMULTANEOUS
FLOAT TEST SWITCH
GROUND FAULT SYSTEM
GRID. FAULT RECEPT.
GRID. MONITOR RELAYS
HEATER/THERMOSTAT 50 WATT STRIP
INDUSTRIAL RELAYS
INTRINSIC BARRIER
INTRINSIC RELAYS
JUNCTION BOX 304SS
LEVEL LIGHTS LEAD, LAG, OFF
MAS UNIT SUPPLIED BY OTHERS
MODULE (1 PH)
MPE - PMR2 - MOISTURE PL
NEMA 4 H -A, SPRING RET.
NEMA4 HOA
O & M MANUAL PLC O &M MANUALS
STACON INCORPORATED
(OFF SWITCH
ERLOAD PL
ERLOAD RESETS
4SE MONITOR
=ED POT
JVER ON LIGHT
NP FAIL PL
NP CALL
NOTE ALARM TERM
SETS
V LIGHTS
2VICE ENT. LABEL
RRING FAN W/THERMOSTAT
3 -MEGS
RGE ARRESTOR SDSA3650
ANAL SPUTTER
=RMAL PL
=RMAL TERMINALS
-S UB10.241
RELAYS
E CLOCK
ER, REPEAT CYCLE
3GLE HOA
NTROL TRANSFORMER
%NSFORMER 24 VAC
JUBLE LIGHT /SWITCH
iS
SEE NOTE BELOW
LTM ETER
OTHER
'TARTUP DAYS
his control panel will operate (2) 20HP, 230V, 3PH, FLA 54 N.EC.; remote pumps (by others).
IDSA3650 Surge Arrestor With Surge arrestor Breaker Added To Quote.
unction Box For Motor Leads, Transducer and Floats Added To Quote.
:ontrol panel will alarm on High and low level.
he primary control Signal will be from a remote submerisble
ansducer. This transducer is existing and by others.
he PUMP 1 / 2 / BOTH Switch will no longer be apart of this job.
1) Square D - M340 PLC with Ethernet +Serial, & w/8 -slot backplane, (2) 16 DI 24VDC,
?) 16 DO 24VDC, (1) 4- Channel analog input, & (1) 2- channel.
nalog output. (1) USB programming cable.
:ost for programming of the PLC by Stacon included.
?) MPE - PM R2 for moisture and overtemp quoted & included.
1) 12X12 Space for customer Supply "Viper" Radio. Viper Radio Supply by customer.
to Local HMI Screen require per customer.
I) internal shelf for Supply Viper Radio included.
I) Backup float circuits quoted. Add rfor (3) Anchor Scientific Rot. -float s an. . NC): $106.47.
?) Square D drives (AT V61) constant torque with keypads and remote mounting kits for keypads Included .
startup price included in price. EDCO 4 -20 and Bussmann 120V Surge arrestors added to quote.
his control panel will be remotely control by the City of Winter Springs SCADA System.
he Viper Radio will communicate Serially.
1) Electronic copy of O &M Manual included.
I)GR - Russell Stoll. JPS2044FP w /box& angle adapter quoted. Need to In stall on the side of control pane1 .
rider cost for (1) Unity License Copy PLC Programming Software: $1,198.00. Add if needed.
ain Guage remote & by others.
he Name 4X 304, SS enclosure will be de -rated to a Name 3RX due to use of air vents & Fan.
UOTED PER PLANS
Schedule,
Weeks:
PRICE
.'.'.$25928."
Estimated Production Time from release of order
Drawings:
4
FROM
Judy Cunningham
THIS PANEL IS QUOTED WITH A ONE YEAR WARRANTY
Shipment,
TBD
ORIGINAL DATE
3/17/2015
Generally excluded from the above quoted prices are the following: Motors-
Internal motor sensing
devices-
5KA SCCR RATING
mounting hardware - field disconnects and junctions boxes- remote operator devices -field installation or wiring -
Revised By Chris Lemen On
and any field devices or Service unless explicitly listed
512212016
Quotes are valid forgo days from the date of the quote
Delivery is FOB Shipping Point.
REVISED BY CHRIS LEMEN
One copy of electronic Submittals is included in the quote.
ON 7/19/2016
Engineering time for Submittal drawings will be billed ifthe job is cancelled after submittals
Quote is based on the information supplied at the time ofthe quote, incorrect or incomplete information may void the quote
ALL PANELS RATED MAXIMUM 5KA. SYMMETRICAL RMS UNLESS OTHERWISE NOTED ABOVE
NOTE' PANEL ORDERS ARE NON - CANCELLABLE AND NON - RETURNABLE FOR CREDIT
No warranty will be provided on customer supplied parts Warranty on all StaCon or customer supplied Multitrode or Xylem APP equipment will be One Year Limited.
If customer supplied equipment or the written specs require equipment which is not UL rated for industrial controls, the panel will not be UL listed
Note' Claims for shortages must be mad. within (seven) 7 day. after receipt of shipment, and failure to give such notice will constitute unqualified acceptance and awaiver of all such claims by the purchaser.
Quoted per Spec pages 0
Quoted per plan pages 0
AS GUILTS WILL BE EM ALSO TO
Q sTacon