HomeMy WebLinkAbout2004 02 09 Regular 502 COMMISSION AGENDA ITEM[ 502 Consent Informational Public Hearine Regular X February 9, 2004 Meeting Mg[. r / Authorization Dept. )/7 REQUEST: The Community Development Department- Planning Division and Building Inspection Division requests that the City Commission adopt by Resolution (as referenced in Ordinance 2003-40), revised engineering drawings which adhere to the Florida Building Code and which will be supplied by the City to those entities requesting them and who have an existing dumpster that must come into compliance with Section 9-281 of the Code. PURPOSE: Adoption of the attached revised engineering drawings (which allow steel as a alternative to aluminum and allow an existing asphalt slab as a substitute for a concrete slab) allow the City to supply engineering drawings which have been approved by the Commission as acceptable alternatives for meeting the dumpster screening requirements for those with existing dumpsters that must come into comp:liance with the Code. APPLICABLE LAW AND PUBLIC POLICY: Florida Municipal Home, Rule Powers Act City of Winter Springs' Code, Section 9-281. CHRONOLOGY: May 13,2002- 2nd Reading/Adoption of Ordinance 2002-13 which established dumpster screening standards Aug. 11, 2003- 2nd Reading/Adoption of Ordinance 2003-26 which amended the compliance date for existing dumpsters Nov. 11,2003- 2nd Reading/Adoption of Ordinance 2003-39 which allows existing masonry enclosures less than 6' in height to be grandfathered as long as they meet the. @) 020904 Regular Agenda Item 502 other Code requirements and fully screen the enclosed dumpster Jan. 26, 2004- 2nd Reading of Ordinance 2003-40 which allows vinyl as an acceptable screening material; which exempts existing dumpsters from compliance with setback regulations generally applied to accessory buildings and structures; and which references City-adopted engineering drawings which meet the minimum screening requirements. CONSIDERATIONS: . Standard engineering drawings provided by the City will help to alleviate some of the expense to comply with the new regulations. · As directed by the City Commission on January 26, 2004, revisions have been made on the drawings to clarify the issues discussed. . In particular, the two alternatives previously approved by the Commission have been revised to allow steel as a alternative to aluminum and allow an existing asphalt slab as a substitute for a concrete slab . The City Engineer has provided the following explanation: ./ The live load requirement on the gate does not change with different materials. The dead load and material strength does change with the type of material used. The gate fabricator will take the live load requirement, the strength of the material used and the dead load ofthe gate and will design/build the gate in accordance with the loads specified and the strength of the material that he is using. ./ The slab is not part of the wind load requirement and any base stabilization can be used that is acceptable to the City. The drawing has been modified to make this clear. Also there is so little uplift generated on a fence that it is negligible. The force that must be resisted by a fence during wind loading is an overturning moment. The forces are almost completely horizontal on the footing/embedment STAFF RECOMMENDATION: Staff recommends that the City Commission adopt by Resolution (as referenced in Ordinance 2003-40), revised engineering drawings which adhere to the Florida Building Code and which will be made available to parties whose dumpsters must be brought into compliance with Section 9-281 of the Code. ATTACHMENTS: A- Resolution 2004-06, Adopting Engineering Drawings B- Revised Engineering Drawings COMMISSION AClLION: 020904 Regular Agenda Item 502 ATTACHMENT A Resolution 2004-06 o RESOLUTION NO. 2004-06 A RESOLUTION OF THE CITY COMMISSION OF THE CITY OF WINTER SPRINGS, FLORIDA, APPROVING A SET OF PRE-APPROVED DUMPSTER ENCLOSURE PLANS AND SPECIFICATIONS PURSUANT TO SECTION 9-281(7) OF THE WINTER SPRINGS CODE; PROVIDING FOR REPEAL OF PRIOR INCONSISTENT RESOLUTIONS, SEVERABILITY, AND AN EFFECTIVE DATE. WHEREAS, the City retained CPH Engineering to prepare a standard set of engineering plans for a dumpster that will satisfy the City's requirements under Section 9-281 of the Winter Springs Code; and WHEREAS, Section 9-281(7) ofthe Winter Springs Code authorizes the City Commission to adopt pre-approved plans and specifications for a dumpster enclosure that can be used by the public to satisfy the City's Code requirements; and WHEREAS, it is the intent and purpose of this Resolution to pre-approve one standard set of engineering plans for a dumpster enclosure for use by the public in the City of Winter Springs; and WHEREAS, other engineering plans for a dumpster enclosure may be approved by the City on a case-by-case basis; and WHEREAS, the Ci~y Commission deems it to be in the best interests ofthe health, safety, and welfare of the citizens of Winter Springs to approve one standard set of engineering plans for a dumpster enclosure for use by the public. NOW, THEREFOR.E, BE IT RESOLVED BY THE CITY COMMISSION OF THE CITY OF WINTER SPRINGS, SEMINOLE COUNTY, FLORIDA, AS FOLLOWS: Section 1. Recitals. The foregoing recitals are hereby fully incorporated herein by this reference and are deemed a material part of this Resolution. Section 2. Approved Dumpster Enclosure Plans. The City Commission hereby adopts the dumpster enclosure engineering plans prepared by CPH Engineering and elated February 9,2004. Said plans are attached hereto as Exhibit "A," and fully incorporated herein by this reference. Said plans may be used by the public to satisfy the requirements of Section 9-281 of the Winter Springs Code. City of Winter Springs Resolution No. 2004-06 Page 1 of 2 Section 3. Repeal of ))rior Inconsistent Resolutions. All prior resolutions or parts of resolutions in conflict herewith are hereby repealed to the extent of the conflict. Section 4. Severability. If any section, subsection, sentence, clause, phrase, word, or portion of this Resolution is for any reason held invalid or unconstitutional by any court of competent jurisdiction, such portion shall be deemed a separate, distinct and independent provision and such holding shall not affect the validity ofthe remaining portion hereto. Section S. Effective Date. This Resolution shall become effective immediately upon adoption by the City Commission of the City of Winter Springs, Florida. DONE AND ADO))TED in regular session of the City Commission ofthe City of Winter Springs, Florida, this _ day of 2004. ATTEST: JOHN F. BUSH, Mayor ANDREA LORENZO-LUACES, City Clerk Approved as to legal fonn and sufficiency for the City of Winter Springs only: ANTHONY A. GARGANESE, City Attorney City of Winter Springs Resolution No. 2004-06 Page 2 of 2 N o V\ E ~ oj '0 r:: OJ Oll < .... oj :; Oll OJ ~ <1- o 0- o N o ~ ~ Z ~ ~ = U < ~ ~ < DESIGN CRITERIA - WIND SPEED (MINI~tUM) 110 MPH, EXPOSURE B - DESIGN COMPRESSIVE STRENGTH f"'m lIE 1S(X) PSI OF MASONRY AT 28 DAYS - ALLOWABLE STEEL STRESS fs = 24,000 PSI - MAXIMUM HEIGHT ... 0 FEET 4 INCHES .. FOR GREATER HEIGHT ENGINEERING CALCULATIOI':S REQUIRED All. Il.tA TERJALS AND METHODS Of CONSTRUCTION SHALL BE IN ACCORDANCE "ITH DRAWiNGS AND SPECiFiCA rlON$ AND: - THE NA nONAL CONCRETE MASONRY ASSOCIA nON .SPEClFICATIONS FOR DESIGN AND CONSTRUCTION OF LOAD BEAR&NG STRUCTURES.. - ACI 530 "BUllDlNG COOE REQUIREMENTS FOR REINFORCED MASONRY STRUCTURES.. - ACI 318 "BUILDING CODE REOUIREMENTS FOR STRUCTURAl CONCRETE," - MINIMUM ENCLOSURE SHALL PROVIDE') FOOT CLEAR ON .AU SIDES OF THE DUMPSTER. MATER IALS - BLOCK: CONFORM TO ASTM C90. GRADE N, TYPE II TWQ-CELl. S".l5-x.16" (COMPRESSfVE STRENGTH, GROSS AREA 1000 PSI) OR 6"1.8''): 16~ BRICK - NQRWEIGAN STRUCTURAL BRICK . MORTAR: CONFORM TO ASTM C270. TYPE S. MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS - 1800 PSI UTILIZE TYPE II CEMENT AND TYPE S LIME. MASONRY CEMENT W1Ll NOT BE CONSIDERED. . GROUT: CONFORM TO e17G, COURSE GROUT. MfNlt'<<UM COMPRESSNE STRENGTH AT 28 DAYS. 2000 PSI . STEEL: OUR~WAl OR EQUAL JOINT REINFORCEMENT AT EVERY SECOND COURSE (lGw Q.c.) AND FILLED CELL REINFORCEMENT AS PER DRAWINGS (ASTM A615. GRADE 60) - CONCRETE: MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS 3000 PSI. - GATE SHAU SUPPORT A TOTAl UVE lOAD OF 200#, (POINT LOAD AT THE END) PER GATE. -IMPERVIOUS BASE SLAB IS RECOMMENDED FOR GROUND STABILIZATION UNDER DUMPSTER, BUT IS NOT REQUIRED TO MEET WIND LOADS OF THE ENCLOSURE. FOOTER SHO\NN AT WAll SECTlON IS REQUIRED. NOTE: TH!S D?.A~.'!NG !S .^. STl'~"m.\P.D nSA:L ~.~EET:NC T:1E REQUIREMENTS OF THE CITY OF WlNTER SPRINGS CODE FOR THE PARAMETERS AND CONDITIONS A..'5 STATED HEREON AND HAS BEEN PREPARED FOR USE 'MTHIN THE Qrv OF WINTER SPRINGS ONLY. A SIGNED AND SEALED COPY IS ON FloE AT THE OFFlCES OF THE CITY OF\\11\'TER SPRINGS. THE SIGNED AND SEAlED COPY IS THE OFFICIAL AUTHORIZED DRAWING. ANY CHANGES OR At.. TERATlONS TO THIS DETAIL MUST BE SUBMmED FOR APPROVAL AND SUBMITr AI. MUST BE SIGNED AND SEALED BY A FLORJDA REGISTERED ENGINEER. VNll~'S 1 :'~~T """--- ...QARaqo..c.. A."C)"r~ fll.:.l:DCCllS ~SliALlM; l>.o.l.."TCDS'TlY.iCO Cl{ARC~Cr...""'.. ~~~~ It;JlUlNOF-"CA:IE " 900'~1l ~JClI;T ''It;!''''CKC.''.L1!',J'llfjHrc..c. tJ"'~ 11"\ ~ .. 111" . VARIES MAXIMUM DIMENSIO 18'-5" MINIMUM DIMENSIO 6'-0" . SCALE: N.T.S. WALL SECTION ',50 :: ~ 1"00 I ~: TONGUE AND GROOVE SLAT '.D60 'Itj~m 6d 2" X 3" POST AND PANEL FRAME . . VARIES "'AX1MUM DIMEtl:SIQI\,I '2' MINIMUM DIMENSION 8' . . -, ""r 8"_ 4- BOLLARD EMBEDDED IN FOOTER SlAB ~ \" ASPHALT CONCRETE \ NEW OR EXISTING . 30- FOOTER 8" CMU WALL . . 40" MAXIMUM SPACING ON FillED REBAR CORES . . #4 6A.~ VERTICAL , CORE FLlEO (lVP) "'- 4- BOllARD ITVP) . ALUMINUM GATE MATERIALS (ALTERNATE) SCAlE: N_T.S. ~."IiT'.AT<:" \/wMl. COtOR) r-- .-DIA.STL8OU.ARD Zl F1UEO Wi CROUT ~ " BOLLARD DETAIL N.T.S. l"X ~8GA. IolETAlOECI< GATE JAMB DETAIL N.T.5. DOUBlE SWING GATE PLAN VIEW SCAlE: N,T,$. 1& GA. ClE....I(fO. PRINf.{.I ^ PA.I.'iTEO DOUSL.E: LE-'F lAETAl GA1E. fBOX n18i AlTERW\TIVE IS A ""'ELDEON.U~UHU"" GATE LtAOE: FROMA. I~.ICH T&C SLAt AND no- POST mo PN'El. ~"I' , '" BARS VERTICAL .c-o-c. 11/2"X 1112"'X)W1r. NfOLE OIAGQtW. BRAeF. [j 6" SLAB NEW OR EXISTING PAINT STEEL CAre ro MATCH BUILDINC \=:XiERIOR SEMI GlOSS) MAXIMUM 12'.Q (2.6'-C"'I..EA..S) N.T.S. GATE ELEVATION w OC ::J~ CJ u: o OC <{ o Zo <{OC I-<{ (/)0 Wz OC<{ ::JI- (/)(/) O::J .J;:E Ou ai::J OC~ wI- I-W (/)0 CL ;:E ::J o (/) CJ Z a: CL (/) OC W I- Z ~ u.. o ~ U '0 ~ o 5- a. <{ c: o 0; :; '" a: " 10 o ~~~~ ~.. g ....W N 1i3 '< ai U.Oai u.. W W l1. <'l o V") E ~ '" -0 r:: .., OIl <: ... i::! ;:l OIl .., ~ '<t o 0\ o <'l o ~ ~ Z ~ ~ == U < ~ ~ -< DESIGN CRITERIA - WIND SPEED (MINIMUM) 1 'lO MPH, EXPOSURE B - DESIGN COMPRESSIVE SiRENGTH rm = 1500 PSI OF MASONRY AT 28 DAYS - AlLOWABLE STEEL STRESS Is =- 24,000 PSI - MAXIMUM HEIGHT * 7 FEET to FOR GREATER HEIGHT ENGINEERING CAlCULATJQNS REOUIRED ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS AND: - ACI 530 -BUILOING CODE REQUIREMENTS FOR REINFORCED MASONRY STRUCTURES: ~ ACI 318 ~BUILDING ('.DOE REQUIREA..u::NTS FOR STRUCTl....RAl CONCRETE: - MINIMUM ENCLOSURE SHALL PROVIDE 2 FOOT CLEAR ON ALL SIDES OF THE DUMPSTER. MATERIALS - GROUT: CONFORM TO C416, COuRSE GROUT. MINIMUM COMPRESSIVE STRENGTH AT 28 OA VS - 2000 PSI - CONCRETE: MINIMUM CCMPRESSNE STRENGTH AT 28 DAYS 3000 PSI. - GATE SHAll SUPPORT A TOTAl liVE lOAD OF 200# (POINT LOAD AT THE END l PER GATE. . VINYL FENCE SLATS SHAlL BE MINIMUM 1/16" WAll THICKNESS - VINYL POSTS SHAll BE 5".5- - 0.150 INCHES MINIMUM WAll THICKNESS (HEAVY WAll) - VINYL RAllS SHALl BE MINIMUM 0.125 INCHES WAtL THICKNESS . PVC SHALl. COMPLY WITH ASTM 01784-1-<3448 - TENSILE STRENGTH 65OOp:s1- AST'" 0638 -IMPERVIOUS BASE SLAB IS RECOMMENDED FOR GROUND STABILIZATION UNDER OUMPSTER. BUT IS NOT REOUIRED TO MEET WIND LOADS OF THE ENCLOSURE. lB- CONCRETE ENCASEMENT OF THE POSTS IS REQUIRED. NOTE: THIS DRAWING IS A STANDARD DETAIL MEETING THE REQUIREMENTS OF THE CITY OF WINTER SPRINGS CODE FOR THE PARAMETERS AND CONDITIONS AS STATED HEREON AND HAS BEEN PREPARED FOR USE WITHIN THE CITY OF WINTER SPRINGS ONLY. A SIGNED AND SEAlED COPY IS ON FilE AT THE OFFJCES OF THE CITY OF V'JlNTER SPRlt-lGS. THE SIGNED AND SEALED COpy IS THE OFFICIAl AUTHORlZED DRAWING. ANY CHANGES OR Ai. TERA TIONS TO THIS DETAIL MUST BE SUBMITTED FOR APPROVAl AND SUBMITTAL MUST BE SIGNED AND SEAlED BY A FLORIDA REGISTERED ::NGINEER. 1.060 1-1 --I f 3.00 1 I~I 2"X3- ALUMINUM FRAME 1.00 1 SCALE: N.T.S. lODIA.STI....BOl.l..ARO FlU EO Wf GROUT ~ ,., BOLLARD DETAIL N.T.S. ~ ~ VINYL FENCE PANEL N.T.S. PRlW,RY GJ.;E: VIHn C<:M:H WJ N..~!o!~.llot FAAWE. "'-'" $l.ItISlIIl.:n:l>Tt::f\- fRAll.EfCR,o,Ll:"'I1~ """". POST MAXI",*.MU'q (2.lIJJ"LEAf-S) l~ j'~ i~ ~ , 112"l.111T..1I1cr A>>J,l!:; OIAOO!W. .....'" ~M~IIo"1Jl.\) U"; a_ _._.__ ._h_ _ . ............-.-.........,......... =]~~.I.............,. A8O'w'E EItr'..ASEMErn(TYP) iRl;;CUIRED) GATE ELEVATION N.T.S. AlTERNATE GATES: ALUMINUM OR STEEL GATE AS SHOWN ON FIGURE 1 - DUMPSTER ENCLOSURE STANDARD DETAIL I CMU STANDARD MAY 8: USED ~W<. DIMENSION' Z MIN. DIMENSION 8' . "'-.- AO":RO (TYP) ~ '" Z 2 0 0 U; U; j Z 2 "' "' ::> ::> . r IMPERVIOUS J . i5 i5 SLAB (EXTENDS 6' ~ Z OUTSIDE POSTS) ::> " , NEW OR EXISTING VINYL FENCE - TONGUE AND GROOVE SOUD SPACING VINYL FENCE POST TYP. 6' O.C. MAXIMUM SPACING CONCRETE FILLED WlTH 2.... BARS OR EQUIVAlENT REINFORCING PER MANUFACTURER AND SUBMITTED FOR APPROVAL . o . . o ~DOUBLE SWING ~TE PLAN VIEW SCAlE: 1-:: 4' VINYL RAIL AND TONGUE AND GROOVE PANELS ATTACHED TO FRAME VINYL FENCE POST SEe ABOVE 7 r---d.. 117 DIAX 8" BARREL i:d:l BOt T LOCK (ONE GATE) II ~ \ 117' DIA. X 12'" CANE BOLT ONE GATE 1 112"X 1112'"X 3/'6" AlUMINUM ANGLE OlAGONAl BRACE \VELDED (MINIMUM) 5")( 5")( 1/4- STEEL TUBE Wi S-X 5~X 1/4" CAP PLATE EMBEDDED 36-INTO 18" OIA. CONC. FOOTING #4 BARS - CONTINUOUS GATE .JAMB DETAIL N.T.S. w a: ::;)N Cl u: z o i= Cl. o ..J >- Z ~ <: I- W o W Cl: ::;) (f) o ..J U Z W a: W I- (f) Cl. ::: ::;) o m (6 ;!; Cl: Cl. (f) Cl: w I- Z ~ u. o >- l- t) "0 .. > e a. a. 0<( c o <ii ;; .. Cl: .. " o ~~<:J<:J w ~ ~.. 0 I- W N &l~ai U.Oai u. W W U.