HomeMy WebLinkAbout2004 02 09 Consent 207 COMMISSION AGENDA. ITEM 207 Consent X Informational Public Hearing Regular February 9, 2004 Regular Mee:ting ~- cSY Mgr. / Dept. Authorization REQUEST: The Parks and Recreation Department is requesting authorization to piggyback off the City of Clewiston Bid # 02-03-11 for Irrigation Pump Station replacement at Central Winds Park. PURPOSE: The purpose of this item is to request authorization to piggyback off of The City of Clewiston Bid # 02-03-1l Irrigation pump station replacement at Ctmtral Winds Park in the amount of$ 35, 886.02. CONSIDERATIONS: . FRDAP Grant 5 was approved at the 9/22/03 City Commission Mee:ting (Central Winds Park support facilities need to be competed to meet Grant requirements). . Parks and Recreation consulted with several Pump Station Companit~s to price out a new Pump Station at Central Winds Park. . The best available price is by piggybacking the City of Clewiston Bid with Hoover Pumping Systems. . The new pump station will be able to handle irrigation on the existing sports fields and the new expansion practice fields. . The Public Works/Utility Director has reviewed the Irrigation Pump Station information. FUNDING: $ 200,000 - FRDAP Grant # 5 Funds were provided in the budget. RECOMMENDATIONS: The Parks and Recreation Department recommends that authorization be given to piggyback off of The City of Clewiston Bid # 02-03-11 for Irrigation Pump Station Replacements at Central Winds Park in the amount of $ 35,886.02. IMPLEMENTATION SCHEDULE: , The new Irrigation Pump Station will be completed within 60 days of approval. ATTACHMENTS: Attachment #1 Hoover Pumping Systems Proposal. COMMISSION ACTION: f'/.., r....' .OVER ATTACHMENT #1 REVISED PROPOSAL 5497-11989 January 30, 2004 PUMl'lNa S'tSTl!:M$ Company: City of Winter Springs Attention: Steve Rictlart Tel: 321~303-7215 Fax: 407-.327-4763 RE: City of Winter Springs Central Wiinds Pk Replacement - lnigation Pump Station Hoover Pumping systems will fumish one Hoovet model HC2-3OJ10PD460I3-ALQ-Z pressure demand irrigation pump system with (2) - 30 horsepower three phase centrifugal pumps delivering an estimated 500 total GPM at the station discharge at 10' lift with the following features: · 10 horsepower centrifugai jocfc;ey pump with pressure sensor In the volute · U.L. listed self-diagnostic pressure startlflow retirement control panel assembly in NEMA 4 enclosure with through door disconnect, individual pump fuses, IEC starters and overload, elapsed time meters, status indicator lights for low pressure, loss of prime, pump thennal. service required and counters for time in each mode- hand or automatic, and number of occurrenceS for each shutdown, transient surge protection · Reduced voltage starters for alllTlotors · 4" control valve with pressure re.:tucing and sustaining pilots, limit switch, pressure gauges up and downstream of the control valve and large capacity disk fitter and 2" parallel control valve for jockey · (2)- 30 horsepower centrifugal pumps providing 250 GPM each @ 240 TDH with thermal :sensor In the volute and Tl::FC motor · Galvanized steel mounting skid, discharge header, butterfly valve at header and each pump discharge, 47 gal. 125 PSI hydro-.pneumatic fiberglass pressure tank with isolation valve and hose btb · Automatic bypass of pump station when inlet reclaim water pressure is adequate for Irrigation use · InstallS" PVC pipe up to 120' to lake, above ground, with rip-rap/rebar supports, flanged swing check valve and 316 stainless steel suction screen · InstaU au galvanized pipe to existing reclaim line with swing check valve · Instan 6" diameter galvanized roll groove discharge pipe and fittings to below grade with 30" PVC adapter for main line tie-in by Hoover · Install customer supplied back flelW preventer. Customer to Instruct Hoover as to local codes for installation. · 1-year parts and labor warranty · One service call to perform initial Startup and Calibration Lump Sum Price: $35,886.02 Note: Efecb1cal Hrvice, wncrvte pad, ,.dditiomtl suction ~e, and pennits are not Included. Customer to remove one side of eeeurity fence for aCC8S$ to pump station. Back:flow protection of water source not included. . Sales tu not tncIuded. F.O.B. Winter Sprfngs. Please caR if pump performance or other features do not meet project criteria. Thank you for your consideration. Sincerely, HOOVER PUMPING SYSTEMS ~ k.~ George Newman 2620 N.W. 15th Court. Pompano Beach, Florida 33069. (954) 971-1350. Fax (954) 975..0791