Loading...
HomeMy WebLinkAbout2004 01 26 Regular 506 COMMISSION AGENDA ITEM 506 Consent Information Public Hearung Regular X January 26, 2004 Meeting MGR. /l- /Dept. ~ REQUEST: The Community Development Department requests that the City Commission, in its capacity as the DRC, consider a signage request by the Transformations II Tanning and Skin Care tenant of the JDC Town Center Building No 8 for the north side of the building (that part of the building abutting the parking lot). PURPOSE: The purpose of this agenda item is to review a proposed partially backlit sign for a Building No. 8 tenant at the roc Town Center ("Transformations II" is not illuminated). The sign is longer than what was previously approved by the City Commission (October 1, 2002, as revised July 28, 2003), in that one 18 :f()ot long sign, approximately 3 feet tall (54 square feet) is proposed in lieu of2 separate (2 feet x 10 feet) signs along the parking lot side of this portion of the building. No additional signage is requested along Doran Drive, although the architectural renderings depicted signage there. CONSIDERATIONS: The staffDRC reviewed the proposed signage on January 6 and again on January 20,2004, and recommend approval, subject to the sign being better centered on the applicable portion of the building (it appears to be centered over the rear door). The proposed signage appears to meet all applicable regulations (e.g. 10 % of the applicable 30' wide x 24' tall portion of the fac;ade is allowed by the Town Center Code - subject to the Commission's approval) and requirements, but is 10nger than what was approved on the elevations at either date. Any variation from the dimensions and/or location of signage depicted the approved elevations requires staff to bring the proposed signage back to the City Commission for approval. 1 January 26, 2004 Regular Item 506 Page 2 The applicant's proposed individual letter partially backlit signage is consistent with code, but is longer and taller (one 3' x 18' rather than two 2' x 10') than what was depicted on the elevations approved at the July 28,2003, City Commission meeting. Backlit signs are allowed in the Town Center. FINDINGS: The proposed signage is consistent with the Town Center Code, but requires City Commission approval. RECOMMENDATIONS: Staff recommends that the City Commission, in its capacity as the DRC, approve the revised signage for the Tanning Salon at the pertinent portion of the north side of Building No.8, subject to centering the sign on the applicable portion of the building, rather than centering it on the doorway. ATTACHMENTS: Attachment A Original architectural rendering with sign approved October 1, 2002 Attachment B :Proposed signage COMMISSION ACTION: 2 30'-0" REAR STOREFRONT 18'-0" 9' -7" r 1 (7 ][ ~[l.r....."..I.. 1.III.U.e A..i ~.....,tlIl.i" e... &.-n. ..~. - 1..1....UIl.~.. ~.n ~ "'-J I 1-1/2- LETTER LAYOUT - REAR ELEVATION: SCALE 1/2" = 1'_0' 3" 3" I GENERAL SPECIFICATIONS SIDE VIEW NON-ILWMINATED FLAT-CUT-OUT 1/2" SINTRA LETTERS "Transformations II" SCALE 112" = 1'-0" , PAINTED LETTERS RED ILWMINATED REVERSE CHANNEL LETTERS "TANNING & SKIN CARE" FABRICATED .063" AWM. RETURNS. .125"AWM. FACES, PAINTED RED RETURNS & FACES. 3/8" BRUSHED SILVER VINYL BORDER ON LETTER FACES. INTERNAL ILWMINATION BY RED NEON TUBING POWERED BY REMOTE TRANSFORMERS .. r MECHANICAL FASTENER AS REO'D THREADED SUPPORT ROD .063' TK ALUMINUM RETURN NEON TUBE SUPPORT LEXAN SG 400 BACK .125' TK ALUMINUM PLATE FACE RUBBER BOOT NEON TUBE TRANSFORMER METAllIC FLEXIBlE CONDUIT TO REMOTE TRANSFORMER BOX HOUSING 30MA UNIT(S) ALUMINUM 'r BRACKET iW WEEP HOLE 120 VOLT 20 AMP PRIMARY ELECT. 00. BUILOING WALL OR FASCIA - &. Res. t1' 0000067 ~ l 1/2~ @ UNOERII.'RJTERS t: LABORATORl~ 0 U~.u ElEC1RIC SIGN 30'-0" REAR STOREFRONT 1/2" F.e.D. SINTRA LETIERS 4 r MT. HARDWARE AS REQ'D "'!DING FASCIA_f SECTION DETAIL SCALE: NTS 603 Wat1erly Lane. Maitland, FL 32751 Phone (407) 290-5591 . FllX (407) 29().9559 Noles: Approved By ~EQVlcr. . IN~TALJ,^TION . NEON . J,ICIlTJNC . VINn . SAS"D mM'l'f.D ALl, YOUQ SICNACf. Nf.tDS Date /Trans Back-R 1 Date: 012604 The following Document was distributed on 01/26/04 during Regular "506" 9'-7" t . 1 (7" B :{y......--i .\....~ ~. vvi,v!".:' ...... ~/-' ~lfti '.J' .... ... r MECHANICAl FASTENER AS REa'D THREADED SUPPORT ROD .063' TK AWMINUM RETURN NEON TUBE SUPPORT LEXAN SG 400 BACK .125' TK AWMINUM PLATE FACE RUBBER BOOT NEON TUBE TRAtlSFORMER METALliC FlEX1BLE CONDUIT TO REMOTE TRANSFORMER BOX HOUSING 30MA UNIT(S) Al.UMltIDM 'l' BRACKET 1/4' WEEP HOLE 120 VOLT 20 AMP PRIMARY ~t CKT. BlJlU)ING WAlL OR fASCIA ~ &. ccg. l'l' 0000067 30' -0' REAR STOREFRONT 18'-0" . 1 1/2~ ~: " LETTER LAYOUT - REAR ELEVATION: SCALE 1/2" = 1'-0" GENERAL SPECIFICATIONS NON-ILWMINATED FLAT-CUT-OUif ~4: ;;iNTRA LETTERS "Transformations II" PAINTED LETTERS RED IlWMINATED REVERSE CHANNEL lETTERS "TANNING & SKIN CARE" FABRICATED .063" AWM. RETURNS. .125"AWM. FACES. PAINTED RED RETURNS & FACES, 318" BRUSHED SilVER VINYL BORDER ON LETTER FACES. INTERNAllLWMINATlON BY RED NEON TUBING POWERED BY REMOTE TRANSFORMERS SIDE VIEW SCALE 1/2" = 1'-0" 1n: EC.O. SINTRA lETTERS MT. HARDWARE ASREQ'O f BUILDING FASCIA -f SECTION DETAIL SCALE: NTS 603 Waverly Lane. Maidand. FL 32751 Phone (407) Z90-5591 . Fax (407) Z90-9559 Notes: Date Approved By Sf.DVlCf. . INSTALlATION . l\1:0N . I.ICIlTlNC . VlN'!1, . SAND BIMTID :\LI. YOUR t\lICNhCE NEm~ !Trans Back-R2