Loading...
HomeMy WebLinkAbout2016 08 08 Consent 302 Lift Station Panel ReplacementCOMMISSION AGENDA ITEM 302 Informational Consent X Public Hearings Regular August 08, 2016 KS KL Regular Meeting City Manager Department REQUEST: The Utility Department requesting authorization to purchase two wastewater lift station control panels from Stacon Inc. in the amount of $51,856.00 plus a 10% contingency. SYNOPSIS: This project consists of replacing the control panels for lift stations 1W and 5E. A lift station has two pumps that convey wastewater collected via a gravity sewer system to the wastewater treatment facility and a control panel contains all the electronics to operate the lift station. CONSIDERATIONS: This project is needed to replace the control panels for two of the City's larger wastewater lift stations; 1W on Cory Lane and 5E which is adjacent to Winter Springs Boulevard across from Tuscawilla Greens. Both stations have two 20 HP pumps and the control panels have deteriorated to the point that their reliability may be compromised. Both panels are approximately 20 years old. The City owns and operates 44 lift stations throughout the City. These two lift stations whose control panels we have targeted for replacement are considered critical to the wastewater operation due to the large areas they serve. Lift stations operate in a highly corrosive environment which deteriorates the components within the station. Consent 302 PAGE 1 OF 3 - August 08, 2016 The panels include; stainless steel enclosure, variable frequency drives, programmable logic controller, alarms, generator receptacle, and surge protection. Two other quotes were received; Rocha Controls - $83,278 and Xylem - $60,720. No disruption of wastewater service is anticipated during this project which should be completed in one day after the panels are received. FISCAL IMPACT: The project cost is $51,856.00 plus a 10% contingency funded by the Utility Enterprise Fund Capital Improvements line code. COMMUNICATION EFFORTS: This Agenda Item has been electronically forwarded to the Mayor and City Commission, City Manager, City Attorney /Staff, and is available on the City's Website, LaserFiche, and the City's Server. Additionally, portions of this Agenda Item are typed verbatim on the respective Meeting Agenda which has also been electronically forwarded to the individuals noted above, and which is also available on the City's Website, LaserFiche, and the City's Server; has been sent to applicable City Staff, Media/Press Representatives who have requested Agendas /Agenda Item information, Homeowner's Associations/Representatives on file with the City, and all individuals who have requested such information. This information has also been posted outside City Hall, posted inside City Hall with additional copies available for the General Public, and posted at six (6) different locations around the City. Furthermore, this information is also available to any individual requestors. City Staff is always willing to discuss this Agenda Item or any Agenda Item with any interested individuals. Consent 302 PAGE 2 OF 3 - August 08, 2016 RECOMMENDATION: Staff recommends the City Commission authorize the purchase of two wastewater lift station control panels from Stacon Inc. in the amount of $51,856.00 plus a 10% contingency payable from the Utility Enterprise Fund Capital Improvements line code and authorize the City Manager and City Attorney to prepare and execute any and all applicable documents. ATTACHMENTS: 1. StaCon Quote per panel (1 page) Consent 302 PAGE 3 OF 3 - August 08, 2016 TO: City of Winter Springs ATTN: Geoff Marbes QUOTE NO.: 120955AD PUMP MODEL: HP: 20 VOLTAGE'. 230 PHASE: 3 WIRE: 3 NO PUMPS/MOTORS: 2 PUMP FLA: N. E. C: 54 JOB NAME: City of Winter Springs -Lift Station 1 West ENCLOSURE APPROX. ®3RX I. 62X48 BOX I BOX N BOX X18 CUSTOM ENCLOSURE MCC MATERIAL 0304SS ENCLOSURE BRAND - -- HOFFMAN MODIFICATIONS X AIR VENTS ALARM CAGE X DEAD FRONT DOORSTOP DRAINS X DRIP SHIELD INSULATION X THREE POINT LATCH LEGS PARTITION SKIRTS SPECIAL POWDER COAT COLOR ST STEEL LEGEND SCREWS SUN SHIELD TEMPERATURE SENSOR WINDOW AIR CONDITIONER X INTRUSION SWITCH MOTOR STARTERS AMBIENT OVERLOADS AUX CONTACTS NEMA MOTOR STARTER SOLID STATE MOTOR STARTERS SOLID STATE OVERLOADS PHASE CONVERTORS VFD ATV312 X VFD- LINE FUSES X VFD- LINE REACTORS CONTACTOR BREAKERS AUX CONTACTS X CONTROL Q -FRAME X EMERGENCY 0 EXTRA SINGLE POLE FUSIBLE DISCONNECT X GEN RECEPTACLE JRS2044FR HANDLE X BREAKERINTERLOCK LIGHTING PANEL X MAIN X SURGE ARRESTOR BREAKER***** MOTOR BREAKER PADLOCK ATTACHMENTS X POWER TERMINALS TVSS X RECEPTACLE Q -FRAME TRANSFORMER CONTROL SYSTEM APP CONTROLLER TOUCH SCREEN MPE BS2000 BUBBLER APG CONTROLLER MULTITRODE (BY OTHERS) MPE CONTROLLER X 3 FLOAT SYSTEM NO FLOATS INCLUDED X PLC SCHNEIDER ELECTRIC -M340 MPE PROBE RELAY PROBE MILTRONICS CONTROLLER MPE INTRINSIC SAFE DUPLEXOR START /STOP PB-S I� PRESSURE TRANSDUCER ULTRASONIC TRANSDUCER X 1PLC PROGRAMMING BY STACON ALARM HORN ALARM LIGHT ALARM SILENCE ALARM TEST ALTERNATOR BY M340 PLC AMMETER W /CT'S ABL 8 (SCHNEIDER ELECTRIC POWER SUPPLY) AWG #14 WIRING BEARING PL BREAKER TRIP PL COPPER GROUND BUS COUNTERS DC ALARM /BAT BACK UP DIALER DIM GLOW LIGHTS ELAPSED TIME METERS ETM SIMULTANEOUS FLOAT TEST SWITCH GROUND FAULT SYSTEM GRID. FAULT RECEPT. GRID. MONITOR RELAYS HEATER/THERMOSTAT 50 WATT STRIP INDUSTRIAL RELAYS INTRINSIC BARRIER INTRINSIC RELAYS JUNCTION BOX 304SS LEVEL LIGHTS LEAD, LAG, OFF MAS UNIT SUPPLIED BY OTHERS MODULE (1 PH) MPE - PMR2 - MOISTURE PL NEMA 4 H -A, SPRING RET. NEMA4 HOA O & M MANUAL PLC O &M MANUALS STACON INCORPORATED (OFF SWITCH ERLOAD PL ERLOAD RESETS 4SE MONITOR =ED POT JVER ON LIGHT NP FAIL PL NP CALL NOTE ALARM TERM SETS V LIGHTS 2VICE ENT. LABEL RRING FAN W/THERMOSTAT 3 -MEGS RGE ARRESTOR SDSA3650 ANAL SPUTTER =RMAL PL =RMAL TERMINALS -S UB10.241 RELAYS E CLOCK ER, REPEAT CYCLE 3GLE HOA NTROL TRANSFORMER %NSFORMER 24 VAC JUBLE LIGHT /SWITCH iS SEE NOTE BELOW LTM ETER OTHER 'TARTUP DAYS his control panel will operate (2) 20HP, 230V, 3PH, FLA 54 N.EC.; remote pumps (by others). IDSA3650 Surge Arrestor With Surge arrestor Breaker Added To Quote. unction Box For Motor Leads, Transducer and Floats Added To Quote. :ontrol panel will alarm on High and low level. he primary control Signal will be from a remote submerisble ansducer. This transducer is existing and by others. he PUMP 1 / 2 / BOTH Switch will no longer be apart of this job. 1) Square D - M340 PLC with Ethernet +Serial, & w/8 -slot backplane, (2) 16 DI 24VDC, ?) 16 DO 24VDC, (1) 4- Channel analog input, & (1) 2- channel. nalog output. (1) USB programming cable. :ost for programming of the PLC by Stacon included. ?) MPE - PM R2 for moisture and overtemp quoted & included. 1) 12X12 Space for customer Supply "Viper" Radio. Viper Radio Supply by customer. to Local HMI Screen require per customer. I) internal shelf for Supply Viper Radio included. I) Backup float circuits quoted. Add rfor (3) Anchor Scientific Rot. -float s an. . NC): $106.47. ?) Square D drives (AT V61) constant torque with keypads and remote mounting kits for keypads Included . startup price included in price. EDCO 4 -20 and Bussmann 120V Surge arrestors added to quote. his control panel will be remotely control by the City of Winter Springs SCADA System. he Viper Radio will communicate Serially. 1) Electronic copy of O &M Manual included. I)GR - Russell Stoll. JPS2044FP w /box& angle adapter quoted. Need to In stall on the side of control pane1 . rider cost for (1) Unity License Copy PLC Programming Software: $1,198.00. Add if needed. ain Guage remote & by others. he Name 4X 304, SS enclosure will be de -rated to a Name 3RX due to use of air vents & Fan. UOTED PER PLANS Schedule, Weeks: PRICE .'.'.$25928." Estimated Production Time from release of order Drawings: 4 FROM Judy Cunningham THIS PANEL IS QUOTED WITH A ONE YEAR WARRANTY Shipment, TBD ORIGINAL DATE 3/17/2015 Generally excluded from the above quoted prices are the following: Motors- Internal motor sensing devices- 5KA SCCR RATING mounting hardware - field disconnects and junctions boxes- remote operator devices -field installation or wiring - Revised By Chris Lemen On and any field devices or Service unless explicitly listed 512212016 Quotes are valid forgo days from the date of the quote Delivery is FOB Shipping Point. REVISED BY CHRIS LEMEN One copy of electronic Submittals is included in the quote. ON 7/19/2016 Engineering time for Submittal drawings will be billed ifthe job is cancelled after submittals Quote is based on the information supplied at the time ofthe quote, incorrect or incomplete information may void the quote ALL PANELS RATED MAXIMUM 5KA. SYMMETRICAL RMS UNLESS OTHERWISE NOTED ABOVE NOTE' PANEL ORDERS ARE NON - CANCELLABLE AND NON - RETURNABLE FOR CREDIT No warranty will be provided on customer supplied parts Warranty on all StaCon or customer supplied Multitrode or Xylem APP equipment will be One Year Limited. If customer supplied equipment or the written specs require equipment which is not UL rated for industrial controls, the panel will not be UL listed Note' Claims for shortages must be mad. within (seven) 7 day. after receipt of shipment, and failure to give such notice will constitute unqualified acceptance and awaiver of all such claims by the purchaser. Quoted per Spec pages 0 Quoted per plan pages 0 AS GUILTS WILL BE EM ALSO TO Q sTacon